文献速递骨肌儿科影像US

儿童青少年下肢附着点超声正常B型与多普勒特征先导研究

Musculoskeletal ultrasonography of lower extremity entheses in children and adolescents - a pilot study of normal B-mode and Doppler characteristics.
PubMed 文献 · Pediatr Radiol · 2026-09-12

全部782个附着点B型回声质地均正常;附着点厚度与年龄显著相关(r=0.65–0.90),性别差异极小;1–44%附着点在插入点2mm内检出轻微能量多普勒信号。结论提示生理性多普勒信号常见于缝匠肌、股四头肌与跟腱附着点,诊断病理性多普勒可能需要伴随B型异常。

要点

  • 健康儿童附着点B型回声质地均正常,厚度随年龄增长而增加(r=0.65–0.90),判读厚度时需参考年龄。
  • 轻微能量多普勒信号在插入点2mm内可见于1–44%附着点,尤其缝匠肌近端与膝部附着点,不能单独作为病变依据。
  • 诊断病理性多普勒信号应结合B型异常表现,单纯轻度血流信号在正常儿童中常见。

核心结论

  • 健康儿童青少年附着点厚度与年龄显著相关(r=0.65–0.90),大多数部位无性别差异。
  • 轻微能量多普勒信号在缝匠肌、股四头肌与跟腱附着点常见,且B型表现正常。
  • 病理性多普勒信号可能需伴随B型异常方可判定,本数据为儿童附着点超声鉴别正常与病理提供基础。

研究设计与样本

  • 行优势侧髋、膝、踝附着点标准化B型与能量多普勒超声检查,并采集人口学、青春期及体力活动数据。
  • 统计分析采用组内相关系数、单因素回归及t检验。

关键影像表现/征象

  • 全部782个评估附着点均显示正常B型回声质地。
  • 能量多普勒信号在插入点2mm内见于1–44%的附着点,扩展至5mm范围时检出率为2–68%。
  • 多普勒信号在缝匠肌近端及膝部附着点出现频率最高。

诊断标准与关键数值

  • 观察者间组内相关系数范围为0.84–0.99,观察者内组内相关系数范围为0.91–0.99,信度为高至优。
  • 附着点厚度与年龄的相关系数r为0.65–0.90,具有统计学显著性。

临床应用与阅片要点

  • 判读儿童附着点厚度时应结合年龄参考,而非直接套用成人或固定阈值。
  • 缝匠肌近端、股四头肌及跟腱附着点的轻度血流信号在正常儿童中常见,报告时需谨慎避免误判为附着点炎。
  • 发现多普勒信号时建议同时评估B型回声质地,B型正常而仅轻度血流信号更支持生理性表现。

局限性

  • 仅评估优势侧肢体,未涉及双侧对比及非优势侧数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Musculoskeletal ultrasonography is an important imaging modality in children. Features of arthritis are well defined and age-related normative data exist. Data on entheses are limited with no consensus on definition of pathology.

OBJECTIVES: The aim of this pilot study was to evaluate entheseal thickness, echotexture, and presence of vascularity in healthy children and adolescents as a prerequisite for distinction from pathology.

MATERIALS AND METHODS: Children and adolescents without musculoskeletal conditions underwent standardized B-mode and power Doppler ultrasonography of the dominant hip, knee, and ankle entheses. Entheseal thickness, echotexture, and vascularity were assessed, alongside demographic, puberty, and physical activity data. Statistical analysis included intraclass correlation coefficients, single regression, and t-tests.

RESULTS: Seventy-nine healthy participants (mean age 10.5 years; 48% female) were included. All 782 evaluated entheses showed normal B-mode echotexture. Inter- and intraobserver reliability was high to excellent, with intraclass correlation coefficient values ranging from 0.84-0.99 and 0.91-0.99, respectively. Entheseal thickness correlated significantly with age (r = 0.65-0.90), lacking sex-specific differences at most sites. Minor power Doppler activity was detected in 1-44% of entheses within 2 mm of the insertion, increasing to 2-68% within 5 mm. Doppler signals were most frequent at proximal sartorius and knee entheses.

CONCLUSION: Entheseal thickness correlates with age, but sex differences are minimal. Mild signals are common at the sartorius, quadriceps, and Achilles entheses with normal B-mode findings. Pathologic Doppler may require accompanying B-mode abnormalities. These data broaden the base for ultrasonography of pediatric entheses and facilitate differentiation of pathology from normal findings.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Hansmann, Roth. Musculoskeletal ultrasonography of lower extremity entheses in children and adolescents - a pilot study of normal B-mode and Doppler characteristics. Pediatr Radiol. 2026. PMID: 42730926. doi:10.1007/s00247-026-06784-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。