文献速递心血管CT

串行CCTA最狭窄冠脉靶病变快速进展的动态临床与影像相关因素

Dynamic Clinical and Imaging Correlates of Rapid Progression in the Target Lesion of the Most Stenotic Coronary Branch on Serial Coronary CT Angiography: A Retrospective Lesion-Level Study.
PubMed 文献 · Acad Radiol · 2026-09-12

该回顾性病变水平研究纳入276例至少接受两次冠脉CT血管成像的患者,匹配同一靶病变并评估快速进展。快速进展定义为年化总斑块负荷增加至少1%。联合模型中,收缩压、同型半胱氨酸、直径狭窄和病变钙化积分的年化变化与快速进展相关,联合模型表观AUC为0.841。

要点

  • CCTA复查时最狭窄冠脉分支靶病变直径狭窄年化变化是最一致的影像相关因素。
  • 病变钙化积分的年化变化对基线病变负荷调整较敏感。
  • 联合模型表观AUC为0.841,相关因素提示斑块演化而非已验证的因果预测因子。

核心结论

  • CCTA靶病变进展与不利的动态临床和病变级影像变化相关,提示斑块演化的相关因素而非已验证的因果预测因子。

研究设计与样本

  • 回顾性病变水平研究,纳入2018年6月至2025年12月间至少两次CCTA检查的276例患者。
  • 采用两次CCTA匹配同一靶病变,使用logistic回归评估年化变化,并进行敏感性分析。
  • 采用ROC分析描述表观样本内判别能力。

关键影像表现/征象

  • 最狭窄冠脉分支靶病变的直径狭窄年化变化是与快速进展最一致的影像征象。
  • 靶病变钙化积分年化变化与快速进展相关,但对基线病变负荷调整敏感。

诊断标准与关键数值

  • 快速进展定义为年化总斑块负荷增加至少1%。
  • 联合模型中收缩压年化变化比值比为1.581,P=0.034。
  • 同型半胱氨酸年化变化比值比为1.954,P=0.001。
  • 直径狭窄年化变化比值比为1.123,P=0.010。
  • 病变钙化积分年化变化比值比为1.258,P<0.001。

临床应用与阅片要点

  • CCTA复查报告应关注最狭窄分支靶病变直径狭窄的年化变化。
  • 靶病变钙化积分变化解读需考虑基线病变负荷的影响。
  • 影像变化联合收缩压和同型半胱氨酸动态变化可辅助识别快速进展风险。

局限性

  • 回顾性病变水平研究,表观AUC仅反映样本内判别,结果不能作为已验证的因果预测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To identify dynamic clinical and imaging correlates of rapid progression in the target lesion of the most stenotic coronary branch using serial coronary CT angiography (CCTA).

MATERIALS AND METHODS: This retrospective lesion-level study included 276 patients with at least two CCTA examinations between June 2018 and December 2025. The same target lesion was matched between scans. Rapid progression was defined as an annualized total plaque burden increase of at least 1%. Annualized changes were assessed by logistic regression with sensitivity analyses. Receiver operating characteristic (ROC) analysis described apparent within-sample discrimination.

RESULTS: Ninety-nine patients showed rapid progression and 177 did not. In the combined model, annualized changes in systolic blood pressure (odds ratio [OR], 1.581; P = 0.034), homocysteine (OR, 1.954; P = 0.001), diameter stenosis (OR, 1.123; P = 0.010), and lesion calcium score (OR, 1.258; P < 0.001) were associated with rapid progression. Diameter stenosis was the most consistent imaging correlate; lesion calcium score was sensitive to baseline lesion-burden adjustment. The combined model showed an apparent area under the receiver operating characteristic curve (AUC) of 0.841.

CONCLUSION: Target-lesion progression on CCTA was associated with adverse dynamic clinical and lesion-level imaging changes, indicating correlates of plaque evolution rather than validated causal predictors.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zhao, Geng, Wang, et al. Dynamic Clinical and Imaging Correlates of Rapid Progression in the Target Lesion of the Most Stenotic Coronary Branch on Serial Coronary CT Angiography: A Retrospective Lesion-Level Study. Acad Radiol. 2026. PMID: 42731901. doi:10.1016/j.acra.2026.08.108

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。