超声>10mm肿块型DCIS的声像-病理对照
本研究回顾性纳入52例经手术证实的常规DCIS患者,术前超声均表现为>10mm肿块型病变。通过多学科共识阅片进行声像-病理对照,将肿块型DCIS归纳为囊内型、簇状轮廓型和硬化性间质型三类。术前超声有50.0%病例被怀疑为浸润,其中硬化性间质型最易误判为浸润。
要点
- 硬化性间质型DCIS最易误判为浸润,报告时应警惕背景硬化对征象的干扰。
- 乳腺腺体界面中断与回声晕常提示浸润,但在DCIS中可由纤维化等引起。
- 囊内型与簇状轮廓型肿块型DCIS被怀疑浸润的比例相对较低。
核心结论
- 超声上>10mm肿块型DCIS可由囊内型、簇状轮廓型和硬化性间质型三种声像-病理模式解释。
- 背景硬化尤其是硬化性间质型可模拟浸润,使术前与浸润性癌的鉴别更加复杂。
研究设计与样本
- 回顾性单中心研究,纳入2020至2023年52例经手术证实的常规DCIS患者。
- 入组条件为术前超声表现为>10mm肿块型病变。
- 排除非肿块异常、≤10mm肿块、新辅助治疗及真空辅助活检病例。
- 超声特征依据日本乳腺甲状腺超声学会JABTS指南进行评估。
- 由多学科共识阅片完成声像-病理对照。
关键影像表现/征象
- 肿块型DCIS分为三种声像-病理模式:囊内型9/52(17.3%)、簇状轮廓型34/52(65.4%)、硬化性间质型7/52(13.5%)。
- 术前超声怀疑浸润者共26/52例(50.0%)。
- 硬化性间质型怀疑浸润比例最高,为6/7例(85.7%),簇状轮廓型为17/34例(50.0%),囊内型为2/9例(22.2%)。
- 可疑浸润的超声表现常与乳腺腺体界面中断和回声晕相关。
临床应用与阅片要点
- 日常阅片遇到>10mm肿块型DCIS时,应意识到硬化性间质型最易模拟浸润。
- 乳腺腺体界面中断及回声晕并非浸润特有,也可见于DCIS伴纤维化或炎症时。
局限性
- 回顾性单中心研究,样本量为52例。
- 仅纳入常规DCIS,排除新辅助治疗和真空辅助活检病例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To clarify the sonographic-pathological correlation of DCIS presenting as masses >10 mm on ultrasonography (US) and identify pathological factors complicating differentiation from invasive carcinoma.
METHODS: This retrospective single-center study included 52 patients with surgically confirmed conventional DCIS presenting as mass-forming lesions >10 mm on preoperative US between 2020 and 2023. Non-mass abnormalities, masses ≤10 mm, neoadjuvant therapy, and vacuum-assisted biopsy were excluded. Sonographic features were evaluated according to the Japan Association of Breast and Thyroid Sonology (JABTS) guidelines. Comprehensive sonographic-pathological correlation was performed by multidisciplinary consensus review to clarify the histopathological architectures underlying mass-forming appearance on US and identify pathological factors associated with US findings suspicious for invasion.
RESULTS: Through sonographic-pathological correlation, mass-forming DCIS were found to fall into three major sonographic-pathological patterns: intracystic (9/52, 17.3%), clustered outline (34/52, 65.4%), and sclerosing stromal (7/52, 13.5%). On preoperative US, invasion was suspected in 26/52 cases (50.0%). Among the three major patterns, suspected invasion was most frequent in the sclerosing stromal pattern (6/7, 85.7%), followed by the clustered outline pattern (17/34, 50.0%) and the intracystic patterns (2/9, 22.2%). Suspicious US findings were frequently related to interruption of the mammary gland interface and echogenic halo. Histologically, background sclerosing adenosis, radial sclerosing lesion, inflammatory changes, and fibrosis contributed to invasion-mimicking findings.
CONCLUSION: The mass-forming appearance of DCIS >10 mm on US could be explained by three major sonographic-pathological patterns: intracystic, clustered outline, and sclerosing stromal. Background sclerosis, particularly in the sclerosing stromal pattern, can mimic invasion and complicate preoperative differentiation from invasive carcinoma.
引用
- Michishita, Tsunoda, Yagishita, et al. Mass-Forming Ductal Carcinoma In Situ >10 mm on Ultrasonography: Sonographic-Pathological Correlation Underlying Mass Formation and Implications for Invasion Assessment. Ultrasound Med Biol. 2026. PMID: 42722535. doi:10.1016/j.ultrasmedbio.2026.08.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。