文献速递头颈甲状腺与浅表CT

50 keV 虚拟单能双能CT联合深度学习重建的甲状腺双低研究

Deep learning image reconstruction for 50-keV virtual monoenergetic dual-energy CT of the thyroid: a prospective "dual-low" dose study.
PubMed 文献 · Eur Radiol · 2026-09-09

结果显示双低组有效辐射剂量降低61%、碘摄入量降低20%,DLIR-H噪声更低且总体图像质量评分显著优于标准方案。

要点

  • 双低方案辐射降低61%、碘量降低20%,适合需反复随访或肾功能临界者
  • 50 keV虚拟单能图像须联合高强度DLIR才能有效抑制噪声并保持边缘锐利
  • DLIR-H噪声纹理接近ASIR-V,主观图像质量近满分,可用于常规报告

核心结论

  • 50 keV虚拟单能成像联合DLIR-H可在甲状腺CT中实现双低扫描,客观与主观图像质量均优于标准剂量方案

研究设计与样本

  • 随机分配至120 kVp、1.0 mL/kg碘、ASIR-V 50%重建的标准组或DECT、0.6 mL/kg碘的双低组
  • 双低组频谱数据重建为50 keV虚拟单能图像,分别用ASIR-V 50%、DLIR-L、DLIR-H三种算法重建

关键影像表现/征象

  • 对比标准方案,DLIR-H图像噪声显著更低,为10.9 HU±2.0对15.3 HU±2.5,P<0.001
  • DLIR-H边缘上升斜率较标准剂量方案更陡峭,提示边缘锐利度更好
  • DLIR-H保持了与ASIR-V相近的自然噪声纹理,主观总体图像质量评分为5.0±0.2,显著优于标准方案的4.6±0.5

诊断标准与关键数值

  • 双低组有效辐射剂量为0.36 mSv±0.05,标准组为0.93 mSv±0.22,降幅61%,P<0.001
  • 双低组碘摄入量为11.7 g±1.8,标准组为14.6 g±4.0,降幅20%,P<0.001
  • 主观评分采用5分Likert量表,DLIR-H总体图像质量评分显著高于标准方案,P<0.001

临床应用与阅片要点

  • 甲状腺增强CT可考虑50 keV虚拟单能成像联合高强度DLIR重建,在明显降低辐射与碘负荷的同时保证诊断质量
  • 阅片时注意50 keV图像噪声被DLIR-H显著抑制,但仍需结合其他重建观察细小结构边缘

局限性

  • 原文未报告研究设计层面的局限信息

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Dual-energy CT (DECT) at 50 keV increases iodine attenuation but exponentially amplifies image noise. The feasibility of using deep learning image reconstruction (DLIR) to counteract this noise under a "dual-low" (low-radiation and low-contrast medium) thyroid CT protocol remains underexplored. To investigate the performance of a dual-low DECT protocol combined with DLIR in contrast-enhanced thyroid CT compared with a standard-dose protocol using adaptive statistical iterative reconstruction-Veo (ASIR-V).

MATERIALS AND METHODS: In this prospective study (August-December 2025), patients were randomly assigned to a standard-dose group (120 kVp, 1.0 mL/kg iodine, ASIR-V 50%) or a dual-low dose group (DECT, 0.6 mL/kg iodine). Dual-low spectral data were reconstructed into 50-keV virtual monoenergetic images using ASIR-V 50%, low-strength DLIR (DLIR-L), and high-strength DLIR (DLIR-H). Objective metrics (CT attenuation, image noise, contrast-to-noise ratio, edge rise slope (ERS), noise power spectrum) and subjective 5-point Likert scores were compared using independent-samples t-tests, paired t-tests, Mann-Whitney U tests, and Wilcoxon signed-rank tests.

RESULTS: Sixty-four patients (mean age, 48.6 years ± 12.2; 49 women) were evaluated (32 per group). The dual-low group achieved a 61% reduction in effective radiation dose (0.36 mSv ± 0.05 vs 0.93 mSv ± 0.22; p < 0.001) and a 20% reduction in iodine intake (11.7 g ± 1.8 vs 14.6 g ± 4.0; p < 0.001). Despite these reductions, DLIR-H demonstrated significantly lower image noise (10.9 HU ± 2.0 vs 15.3 HU ± 2.5; p < 0.001) and steeper ERS than the standard-dose protocol. DLIR-H preserved a natural noise texture comparable to ASIR-V. Subjectively, DLIR-H scored near-perfectly in overall image quality (5.0 ± 0.2), significantly outperforming the standard protocol (4.6 ± 0.5; p < 0.001).

CONCLUSION: Combining 50-keV virtual monoenergetic imaging and DLIR-H facilitates a dual-low scanning strategy for thyroid CT, yielding superior objective and subjective image quality while substantially reducing radiation and iodine burdens.

KEY POINTS: Question How can we counteract the severe noise of 50-keV dual-energy CT to enable a low-radiation, low-contrast scanning protocol for thyroid imaging? Findings Deep learning reconstruction at 50-keV significantly suppressed noise, maintaining edge sharpness and diagnostic confidence while reducing radiation by 61% and iodine by 20%. Clinical relevance This dual-low strategy provides a safer imaging alternative that preserves diagnostic quality. It is highly beneficial for vulnerable patients requiring lifelong CT surveillance or those with borderline renal function amid global contrast media shortages.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Wang, Jin, et al. Deep learning image reconstruction for 50-keV virtual monoenergetic dual-energy CT of the thyroid: a prospective "dual-low" dose study. Eur Radiol. 2026. PMID: 42714621. doi:10.1007/s00330-026-12814-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。