短重复时间用于脑肿瘤23Na-MRI的可行性
本研究前瞻性纳入30例组织病理学确诊的幕上脑肿瘤成人患者,采用3T双调谐1H/23Na鸟笼头线圈与3D径向星堆序列采集23Na-MR图像。通过对比肿瘤与背景信号计算CNR及时间校正CNR效率,比较TR60与TR100对脑肿瘤的显示能力。结果显示两者CNR无显著差异,而TR60的时间校正CNR效率显著更高。
要点
- 23Na-MRI采用TR60可在保持脑肿瘤对比噪声比的同时缩短采集时间。
- TR60的时间校正CNR效率显著优于TR100,提示更适合临床工作流。
- 短TR方案可提高钠成像在脑肿瘤评估中的采集效率。
核心结论
- 23Na-MR成像使用TR60可获得与TR100相当的肿瘤CNR,且时间校正CNR效率显著更高。
研究设计与样本
- 研究类型为前瞻性研究,纳入30例组织病理学确诊的幕上脑肿瘤成人患者,其中男性22例。
- 设备为3T扫描仪,配双调谐1H/23Na鸟笼头线圈,采用3D径向星堆序列采集23Na-MR图像。
关键影像表现/征象
- 23Na-MR图像中肿瘤信号与背景信号的差异用于计算对比噪声比。
诊断标准与关键数值
- 肿瘤显著性以对比噪声比及时间校正CNR效率评估,计算方式为肿瘤信号强度与背景信号强度比较。
- TR60与TR100的CNR无显著差异(p=0.56),TR60的时间校正CNR效率显著高于TR100(p<0.001)。
临床应用与阅片要点
- 23Na-MRI采用TR60可减少采集时间而不牺牲脑肿瘤对比噪声比。
局限性
- 本研究仅纳入幕上脑肿瘤,结果对幕下病变的适用性未经验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: 23Na‑MR imaging requires lengthy acquisition times, it remains difficult to implement routinely in clinical workflows and limits broader clinical application. This study aimed to determine whether a TR of 60 ms (TR60) could maintain brain tumor conspicuity while reducing acquisition time compared to TR100.
MATERIALS AND METHODS: This prospective study includes adult patients with histopathologically confirmed supratentorial brain tumors. A 3 T scanner with a dual-tuned 1H/23Na birdcage head coil was used. A 3D radial stack-of-stars sequence was employed for the acquisition of 23Na-MR images. The lesion conspicuity on 23Na-MR images was evaluated using the contrast-to-noise ratio (CNR) and CNR efficiency (CNR/√ acquisition time; time-CNR), calculated by comparing the signal intensity of the tumor with that of the background. The CNR and time-CNR were then compared between TR60 and TR100 in detecting brain tumors.
RESULTS: A total of 30 patients (22 men) were enrolled. No significant differences were observed in the CNR between TR60 and TR100 (p = 0.56). The time-CNR of TR60 was significantly higher than that of TR100 (p < 0.001).
CONCLUSION: 23Na-MR imaging using TR60 achieved a significantly higher time-CNR than TR100 while maintaining comparable CNR, indicating improved acquisition efficiency for brain tumor evaluation.
引用
- Yamashita, Obara, Kikuchi, et al. Feasibility of Using Short Repetition Time for Brain Tumors in 23Na-MRI. Acad Radiol. 2026. PMID: 42711182. doi:10.1016/j.acra.2026.08.087
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。