文献速递介入腹部DSA

不可切除肝转移瘤经皮肝灌注化疗饱和的体外血流模拟模型

A Novel Flow Model for Demonstrating and Simulating Chemosaturation with Percutaneous Hepatic Perfusion in Unresectable Liver Metastasis.
PubMed 文献 · Acad Radiol · 2026-09-08

针对不可切除肝转移瘤的经皮肝灌注化疗饱和(CS-PHP)技术操作复杂、教学困难,作者利用商用血流模型与自制3D打印肝血管模型构建了体外模拟器。该模拟器可复现CS-PHP全流程,并在2025年欧洲放射学大会上获得超过100名使用者的积极反馈。

要点

  • CS-PHP涉及肝循环隔离、靶向化疗和体外滤过,团队教学难度大。
  • 该血流模型可体外模拟CS-PHP全部操作步骤,适合介入团队培训。
  • 红色染料可替代化疗药物,直观显示药物输送与滤过过程。

核心结论

  • 成功设计并实现了能真实模拟CS-PHP的血流模型,对新手和经验丰富的介入医师均有演示教学价值。
  • 该模型可用于患者教育、血管造影团队培训、工作流程与沟通优化,最终有助于提高安全性和疗效。

研究设计与样本

  • 研究类型为技术开发与教学模拟研究,结合商用血流模型与自制3D打印肝血管模型构建CS-PHP模拟器。
  • 使用红色染料作为化疗药物替代物,模拟药物输送与滤过过程。
  • 模型部署于2025年欧洲放射学大会「The Cube」活动,收集超过100名使用者的反馈。

临床应用与阅片要点

  • 适用于介入医师、血管造影团队及医学生的CS-PHP全流程操作培训。
  • 可用于术前工作流程梳理与团队沟通优化,降低实际手术中的操作风险。

局限性

  • 原文未报告模型的定量验证指标或与真实手术对照的准确性数据。
  • 原文未说明模型在复杂血管解剖变异或血流动力学异常情况下的模拟保真度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Diffuse unresectable liver metastasis of varying dignity are complex to manage and are associated with poor overall survival. Given the wide spectrum of liver-directed therapies including surgery, ablation, radiotherapy, brachytherapy, chemoembolization and chemosaturation an interdisciplinary approach is essential. Chemosaturation with percutaneous hepatic perfusion (CS-PHP) has shown promising developments in the treatment of metastasized uveal melanoma and colorectal carcinoma. However, the procedure is technically complex, involving isolation of hepatic circulation, targeted chemotherapy application and extracorporeal filtration, making it difficult to comprehend and teach not only the physician, but also the entire team, as well as aspiring students. We aimed to develop a simulator enabling demonstration and training of all procedural steps involved in CS-PHP.

MATERIALS AND METHODS: Commercially available flow models were combined with custom 3D-printed liver and vascular models fabricated using our in-house 3d printer. Red dye was used as a surrogate for the chemotherapeutic agent to simulate delivery and filtration.

RESULTS: The CS-PHP procedure could be successfully replicated ex-vivo in our laboratory. We deployed the setup at "The Cube" event of the European Congress of Radiology 2025 with overwhelmingly positive feedback from more than a 100 users.

CONCLUSION: We successfully designed and implemented a flow model that realistically simulates CS-PHP. The model proved useful for demonstrating chemosaturation to both novice and experienced interventional physicians. It has potential applications in patient education, angiography team training, workflow and communication optimization, ultimately contributing to improved safety and outcomes.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Silivasan, Scheel, De Bucourt, et al. A Novel Flow Model for Demonstrating and Simulating Chemosaturation with Percutaneous Hepatic Perfusion in Unresectable Liver Metastasis. Acad Radiol. 2026. PMID: 42705921. doi:10.1016/j.acra.2026.07.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。