基于CycleGAN从全身快速定位像合成T2-HASTE用于体成分分析

Accelerated Body Composition Analysis in Whole-body MRI Using CycleGAN-based T2-HASTE Synthesis From Fast Whole-body Localizers.
PubMed 文献 · Invest Radiol · 2026-09-07

本回顾性单中心概念验证研究纳入468例接受全身MRI(含FWBL与T2-HASTE)的患者,训练CycleGAN从FWBL合成T2-HASTE图像。合成图像经固定预训练BCA模型分割,多数体成分测量与参考T2-HASTE一致性良好,肌肉与SAT误差低而骨误差较高。研究提示从定位像获得定量体成分信息具有可行性。

要点

  • 合成T2-HASTE对肌肉与SAT测量偏移小,肌肉-脂肪比率三分位分层一致率89.4%~95.7%。
  • 骨区测量相对误差最高(5.93%~8.26%),分割重叠最低(Dice 0.76),需谨慎判读。
  • 合成T2图像主观评分均值4.52分,提示对粗粒度体成分评估有潜在附加价值。

核心结论

  • CycleGAN合成T2-HASTE生成的BCA测量与参考T2-HASTE接近,可大体保留体成分分层,支持从全身MRI定位像获得定量体成分信息的加速路径。

研究设计与样本

  • 回顾性单中心概念验证研究,纳入468例同次完成FWBL与T2-HASTE的全身MRI患者,53%为女性,平均年龄51±18岁。
  • CycleGAN模型以配准后的FWBL与T2-HASTE训练,BCA采用固定预训练模型对合成与参考T2-HASTE进行全自动分割。
  • 分割目标包括皮下脂肪组织、肌肉、腹腔、胸腔与骨,并分析胸、腹及全身区域的SAT、肌肉和骨体积。

关键影像表现/征象

  • 合成T2-HASTE对SAT、肌肉、腹腔与胸腔的平均Dice分别为0.90、0.87、0.94与0.91,骨为0.76。
  • 合成T2图像对FWBL粗粒度体成分评估提供附加价值,4位放射科医生5分Likert主观评分为均值4.52、中位5。

诊断标准与关键数值

  • 肌肉平均百分比偏倚在胸、腹、全身分别为-0.05%、3.51%与2.91%;SAT为-0.19%、-1.21%与0.71%;骨为-7.10%、-8.86%与-6.30%。
  • 肌肉中位绝对百分比误差为2.96%~3.52%,SAT为2.03%~3.71%,骨为5.93%~8.26%。
  • 肌肉-脂肪比率三分位不变比例在胸、腹、全身分别为89.4%、93.6%与95.7%,κ=0.92、0.95与0.97。
  • 肌肉减少指数三分位不变比例在胸、腹、全身分别为68.1%、80.9%与87.2%,κ=0.76、0.86与0.90。

临床应用与阅片要点

  • 合成T2-HASTE可优先用于肌肉与SAT为主的体成分粗分层评估,骨相关指标仍需参考原始T2-HASTE。
  • 肌肉-脂肪比率分层稳定性高,比肌肉减少指数更可靠,可用于筛查场景中快速定位异常体成分方向。
  • 阅片时对合成图像中骨分割轮廓应主动核对,避免因Dice较低造成肌肉-骨比值判读偏差。

局限性

  • 回顾性单中心概念验证设计,样本量为468例,研究本身设计存在单中心与回顾性限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate whether CycleGAN-based synthesis of T2-HASTE images from routinely acquired fast whole-body localizer (FWBL) can support accelerated body composition analysis (BCA) by preserving sufficient information for an established T2-HASTE-based BCA pipeline to generate measurements comparable to those derived from reference T2-HASTE images.

MATERIALS AND METHODS: This retrospective single-center proof-of-concept study included 468 patients (53% female, mean age 51±18 y) who underwent WB-MRI with FWBL and T2-HASTE between March 2012 and December 2025, 431 (92%) of whom were examined from 2023 onward. A CycleGAN model was trained to generate synthetic T2-HASTE images from registered FWBL and T2-HASTE images. Fully automated MRI-based BCA was conducted on synthetic and reference T2-HASTE images using a fixed pretrained BCA model, focusing on 5 key segmentation compartments: subcutaneous adipose tissue (SAT), muscle, abdominal cavity, thoracic cavity, and bone, with subsequent region-specific volumetric analyses of SAT, muscle, and bone in the thoracic, abdominal, and whole-body regions. Derived BCA markers included the Sarcopenia Index (muscle-to-bone ratio) and the muscle-to-SAT ratio. Agreement was assessed using Bland-Altman analysis, including mean bias expressed in absolute units and as a percentage of the mean reference volume, median absolute percentage error, Pearson correlation, and weighted Cohen kappa for tertile-based stratification. Segmentation overlap was evaluated using Sørensen-Dice similarity coefficients. In addition, a qualitative reader evaluation was performed by 4 radiologists across 30 cases.

RESULTS: Mean percentage bias across the thoracic, abdominal, and whole-body regions was -0.05%, 3.51%, and 2.91% for muscle, -0.19%, -1.21%, and 0.71% for SAT, and -7.10%, -8.86%, and -6.30% for bone, respectively. Median absolute percentage error remained low for muscle (2.96% to 3.52%) and SAT (2.03% to 3.71%), whereas bone showed the highest relative error (5.93% to 8.26%). Tertile-based stratification agreement was high, particularly for the muscle-to-SAT ratio, with unchanged tertile assignment in 89.4% of thoracic, 93.6% of abdominal, and 95.7% of whole-body analyses (κ=0.92, 0.95, and 0.97, respectively). For the Sarcopenia Index, unchanged tertile assignment was 68.1%, 80.9%, and 87.2%, respectively (κ=0.76, 0.86, and 0.90). Segmentation overlap was high across the main compartments, with mean Sørensen-Dice coefficients of 0.90 for SAT, 0.87 for muscle, 0.94 for the abdominal cavity, and 0.91 for the thoracic cavity, whereas bone showed lower overlap (0.76). Qualitative evaluation showed positive ratings for both synthetic image utility and segmentation plausibility, with the synthetic T2 representation rated as providing added value over FWBL for coarse body composition assessment on a 5-point Likert scale, where 1 indicated strong disagreement, and 5 indicated strong agreement (mean: 4.52, median: 5).

CONCLUSIONS: Combining FWBL MRI with CycleGAN-based image synthesis yielded BCA measurements that closely matched those from reference T2-HASTE images and largely preserved body composition stratification. These findings demonstrate the feasibility of deriving quantitative BCA information from routinely acquired WB-MRI localizer data and support further investigation of accelerated MRI-based BCA approaches using simplified acquisitions.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Bojahr, Quinsten, Kohnke, et al. Accelerated Body Composition Analysis in Whole-body MRI Using CycleGAN-based T2-HASTE Synthesis From Fast Whole-body Localizers. Invest Radiol. 2026. PMID: 42703092. doi:10.1097/RLI.0000000000001307

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。