胎儿MRI自动肺分割用于肺发育不良表型肺容积快速评估

Automated fetal magnetic resonance imaging lung segmentation for rapid lung volume estimation across diverse pulmonary hypoplasia phenotypes.
PubMed 文献 · Pediatr Radiol · 2026-09-05

回顾性研究纳入2016至2025年906例胎儿MRI检查,以专家判定的肺分割为参考,开发并测试总肺容积(TLV)和预测肺容积百分比(PPLV)自动分割流程。自动TLV与手动容积测量一致性良好,推理时间每例约4秒,提示可提升临床流程效率。

要点

  • 自动TLV估计与手动测量一致性良好,可用于肺发育不良产前风险分层初筛。
  • 自动PPLV估计性能低于TLV,阅片时需对PPLV相关解读保持谨慎。
  • 对自动分割表现最差病例进行人工修正,可作为人机协同质控流程。

核心结论

  • 自动胎儿MRI肺分割可快速估计TLV,适用于多种肺发育不良表型。
  • 自动TLV估计与手动容积测量一致性良好,ICC为0.955。
  • 自动PPLV估计性能低于TLV,ICC为0.727。
  • 对最差TLV输出进行人工修正,每例需3.1分钟。

研究设计与样本

  • 回顾性研究,纳入2016至2025年胎儿MRI检查,最终数据集为906例具有完整且可恢复肺分割的检查。
  • 以临床诊疗中获得的专家判定肺分割作为模型开发与测试参考标准。
  • 针对总肺容积(TLV)与预测肺容积百分比(PPLV)分别开发自动分割流程。
  • 平均孕周27.1周,范围16-38周。
  • 对最低表现的TLV输出由胎儿放射科医师判定,以模拟人机协同工作流程。

关键影像表现/征象

  • 自动TLV估计平均Dice相似系数为0.81±0.10。
  • 自动PPLV估计平均Dice相似系数为0.76±0.12。
  • 自动TLV估计中位绝对百分比误差为11.1%。
  • 自动PPLV估计中位绝对百分比误差为14.5%。
  • 平均推理时间为每例检查4秒。

诊断标准与关键数值

  • 自动TLV估计与手动容积测量一致性ICC为0.955。
  • 自动PPLV估计与手动容积测量一致性ICC为0.727。
  • 自动TLV估计平均Dice相似系数为0.81±0.10。
  • 自动PPLV估计平均Dice相似系数为0.76±0.12。
  • 人工修正25例最低表现TLV输出,每例需3.1分钟。

临床应用与阅片要点

  • 自动胎儿MRI肺分割可用于肺发育不良相关疾病的产前风险分层,减少手动分割时间。
  • 自动TLV更可靠,可作为日常报告中肺容积评估的辅助工具。
  • 自动PPLV性能较低,必要时需人工复核并修改自动分割结果。
  • 对自动分割表现较差的复杂病例,应保留专家人工修正环节。

局限性

  • 本研究为回顾性设计。
  • 纳入数据来自临床诊疗中已获得的专家判定分割,可能存在选择偏倚。
  • 原文未报告外部独立测试集或不同中心设备下的泛化验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Fetal magnetic resonance imaging (MRI)-derived lung volume measurements are used for prenatal risk stratification in conditions associated with pulmonary hypoplasia, but manual segmentation is time-intensive.

OBJECTIVE: To evaluate whether automated fetal MRI lung segmentation enables rapid and reliable volumetric assessment across diverse pulmonary hypoplasia phenotypes.

MATERIALS AND METHODS: In this retrospective study, fetal MRI examinations performed from 2016 to 2025 with expert-adjudicated lung segmentations obtained during clinical care were used for model development and testing. Automated segmentation pipelines were developed for total lung volume (TLV) and percent predicted lung volume (PPLV). Performance was assessed using Dice similarity coefficient (DSC), absolute percentage error (APE), Bland-Altman analysis, intraclass correlation coefficient (ICC), case-level risk-category agreement, and inference time. Lowest-performing TLV outputs were adjudicated by a fetal radiologist to simulate a human-in-the-loop workflow.

RESULTS: The final dataset included 906 fetal MRI examinations with complete and recoverable lung segmentations, acquired at a mean gestational age of 27.1 weeks, range 16-38 weeks. Automated TLV estimation showed excellent agreement with manual volumetry (ICC, 0.955; mean DSC, 0.81±0.10; median APE 11.1%). Automated PPLV estimation showed lower performance (ICC, 0.727; mean DSC, 0.76±0.12; median APE 14.5%). Mean inference time was 4 s per examination. Correction of the 25 lowest-performing TLV outputs required 3.1 min per case.

CONCLUSION: Automated fetal MRI lung segmentation enables rapid TLV estimation across diverse pulmonary hypoplasia phenotypes and may improve clinical workflow efficiency while preserving expert oversight for challenging cases.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Choi, Hegde, Dudley, et al. Automated fetal magnetic resonance imaging lung segmentation for rapid lung volume estimation across diverse pulmonary hypoplasia phenotypes. Pediatr Radiol. 2026. PMID: 42700234. doi:10.1007/s00247-026-06765-1