文献速递泌尿生殖MR

IVIM真扩散系数联合PSAD列线图预测临床有意义前列腺癌

A Quantitative Nomogram Integrating IVIM-derived True Diffusion Coefficient and PSAD for Predicting Clinically Significant Prostate Cancer: Comparison With PI-RADS-based Assessment.
PubMed 文献 · Acad Radiol · 2026-09-03

本研究纳入341例总PSA>4 ng/mL且经病理证实的前列腺MRI患者,开发并验证IVIM真扩散系数D联合PSAD的定量列线图。PSAD+D模型在训练、内部验证及前瞻性验证集的AUC分别为0.920、0.900、0.916,诊断效能与PI-RADS+PSAD相当。结果表明该模型可去除阅片者依赖性,且参数精简优于维度最大化。

要点

  • PSAD+D列线图预测csPCa效能与PI-RADS+PSAD相当
  • IVIM参数D及ADC可重复性高,ICC为0.93-0.96
  • 加入ADC未提升效能反而降低区分度,参数宜精简

核心结论

  • PSAD+D列线图预测csPCa的诊断效能与PI-RADS+PSAD相当,同时可消除阅片者依赖性

研究设计与样本

  • 联合回顾性与前瞻性研究,共纳入341例总PSA>4 ng/mL行前列腺MRI含IVIM-DWI并经病理证实者

诊断标准与关键数值

  • csPCa定义为Gleason评分≥7
  • PSAD+D模型训练、验证及前瞻性集AUC分别为0.920、0.900、0.916
  • PSAD+ADC+D模型AUC分别为0.923、0.877、0.917
  • PI-RADS+PSAD模型AUC分别为0.903、0.919、0.936
  • DeLong检验显示三个模型在所有数据集中均无显著差异

临床应用与阅片要点

  • PSAD与IVIM参数D均为csPCa独立预测因子
  • IVIM参数D与ADC具有高可重复性,适合客观定量评估
  • 在PSAD+D模型中加入ADC导致区分度显著下降,报告时不建议额外纳入ADC

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and validate a quantitative nomogram integrating the intravoxel incoherent motion (IVIM)-derived true diffusion coefficient (D) and prostate-specific antigen density (PSAD) for predicting clinically significant prostate cancer (csPCa) in patients with elevated serum PSA, and to compare its diagnostic performance with that of Prostate Imaging Reporting and Data System (PI-RADS)-based assessment.

MATERIALS AND METHODS: This combined retrospective and prospective study enrolled 341 patients (total PSA > 4 ng/mL) who underwent prostate magnetic resonance imaging incorporating IVIM-diffusion-weighted imaging and subsequent pathological confirmation. The retrospective cohort (n = 253) was randomly split into training (n = 176) and internal validation (n = 77) sets; an independent prospective cohort (n = 88) served as the temporal validation set. csPCa was defined as a Gleason score ≥7. Independent predictors were identified from IVIM-derived parameters (D, D*, f), conventional apparent diffusion coefficient (ADC), and PSA-derived indices using multivariate logistic regression. Models of increasing complexity were constructed, and the optimal parameter combination was determined. Diagnostic performance was compared using the area under the receiver operating characteristic curve (AUC), the DeLong test, net reclassification improvement, integrated discrimination improvement (IDI), and decision curve analysis (DCA). PI-RADS alone and PI-RADS + PSAD served as reference comparators.

RESULTS: PSAD, ADC, and D were identified as independent predictors of csPCa. The PSAD + D model achieved AUCs of 0.920, 0.900, and 0.916 in the training, validation, and prospective sets, respectively; PSAD + ADC + D yielded AUCs of 0.923, 0.877, and 0.917; and PI-RADS + PSAD achieved 0.903, 0.919, and 0.936. The DeLong test revealed no significant differences among the three models in any dataset (all false discovery rate-corrected p > 0.05). IDI analysis demonstrated that incorporating ADC into the PSAD + D model resulted in significantly negative discrimination improvement across all three datasets.

CONCLUSION: The PSAD + D nomogram achieves diagnostic performance comparable to PI-RADS + PSAD for predicting csPCa while eliminating reader dependency through objective, highly reproducible parameters (intraclass correlation coefficients: 0.93-0.96). The paradoxical performance attenuation upon ADC addition demonstrates that parameter parsimony, rather than dimensionality maximization, optimizes predictive accuracy in quantitative imaging models.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Li, Chen, et al. A Quantitative Nomogram Integrating IVIM-derived True Diffusion Coefficient and PSAD for Predicting Clinically Significant Prostate Cancer: Comparison With PI-RADS-based Assessment. Acad Radiol. 2026. PMID: 42692876. doi:10.1016/j.acra.2026.08.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。