文献速递泌尿生殖腹部MR

融合成像辅助PI-RADS v2.1评估前列腺mpMRI的多阅片者研究

Fusion-Assisted PI-RADS v2.1 Assessment on Prostate mpMRI: A Multi-reader Observer Performance Study.
PubMed 文献 · Acad Radiol · 2026-09-02

本研究为多中心回顾性研究,纳入327例患者,采用基于稀疏表示的算法将ADC伪彩图与T2WI融合,由一名泌尿生殖放射专家按PI-RADS v2.1解读全部病例,两名放射科医生分别进行常规阅片与融合辅助阅片。结果显示融合成像提高诊断准确性并缩短阅片时间,中心1高年资医生准确性由81.59%升至93.86%,Kappa值由0.632升至0.877。

要点

  • T2WI-ADC融合成像可提高移行带病灶检出和诊断效能
  • 融合辅助阅片可缩短阅片时间,中心1平均时间由114.94秒降至94.84秒
  • 融合成像有助于缩小不同经验水平阅片者间的差异

核心结论

  • mpMRI融合成像作为补充诊断方式有助于缩小阅片者间差异并提高不同经验水平阅片者的一致性
  • T2WI-ADC融合成像作为认知辅助可显著改善移行带病灶的检出和诊断效能
  • 融合方法大幅简化阅片流程并缩短解读时间,同时提高了病灶可视化效果

研究设计与样本

  • 多中心回顾性研究,纳入327例患者
  • 采用基于稀疏表示的算法生成融合图像,将反映肿瘤细胞密度的ADC伪彩图与T2WI解剖细节相结合
  • 一名接受专科培训的泌尿生殖放射专家依据PI-RADS v2.1解读全部327例扫描
  • 两名放射科医生分别在常规阅片和融合辅助阅片两种模式下评估病例,比较阅片时间和诊断效能

关键影像表现/征象

  • 融合图像将ADC伪彩图反映的肿瘤细胞密度与T2WI的解剖细节结合,增强病灶可视化效果

诊断标准与关键数值

  • 中心1高年资放射科医生诊断准确性由81.59%提高至93.86%
  • 中心1阅片者间一致性Kappa值由0.632提高至0.877
  • 中心1平均阅片时间由114.94秒缩短至94.84秒

临床应用与阅片要点

  • 融合成像可作为PI-RADS v2.1评估的补充手段,尤其适用于移行带良性增生结节与恶性病灶的鉴别
  • 融合辅助阅片可缩短解读时间并简化阅片流程,可用于日常报告工作流
  • 融合技术可有效缩小不同经验阅片者之间的差距,适用于低年资医生培训

局限性

  • 本研究为回顾性设计

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Although PI-RADS v2.1 offers a standardized assessment framework, substantial inter-reader variability persists in the evaluation of score-related imaging features. In particular, differentiating benign hyperplastic nodules from malignant lesions within the transition zone poses a major clinical challenge. The aim of the study was to determine the impact of using an mpMRI fusion imaging technique to improve the diagnostic performance of PI-RADS v2.1 for prostate cancer (PCa).

MATERIALS AND METHODS: This multicenter retrospective study included 327 patients. The study utilized a sparse representation-based algorithm to generate fusion images, combining pseudo-color ADC maps reflecting tumor cellular density with the anatomical details of T2WI. An expert fellowship-trained urogenital radiologist interpreted all 327 scans based on PI-RADS v2.1. Two radiologists evaluated the cases under both conventional reading and fusion-assisted reading modes to compare reading times and diagnostic performance.

RESULTS: Fusion imaging facilitates enhanced visualization of tumor lesions. Apart from facilitating better tumor visualization, the fusion approach greatly streamlined the reading process and cut down interpretation time. The technique substantially reduced reading times (in Center 1, the average time decreased from 114.94 s to 94.84 s). Regarding diagnostic performance, the accuracy of the senior radiologist in Center 1 increased from 81.59% to 93.86%, and the agreement (Kappa value) improved from 0.632 to 0.877. Furthermore, the fusion technique effectively narrowed the experience gap between readers. As a cognitive aid, T2WI-ADC fusion imaging significantly improves the detection of transition zone lesions and diagnostic performance.

CONCLUSION: The application of mpMRI fusion imaging as a supplementary diagnostic modality is conducive to narrowing inter-reader discrepancies and improving agreement across readers at different experience levels.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Shi, Chen, Ming, et al. Fusion-Assisted PI-RADS v2.1 Assessment on Prostate mpMRI: A Multi-reader Observer Performance Study. Acad Radiol. 2026. PMID: 42686492. doi:10.1016/j.acra.2026.08.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。