无ECG门控与ECG门控CCTA在早搏患者中的成像表现比较
研究比较无ECG门控与ECG门控冠状动脉CTA在416例早搏患者中的检查成功率、图像质量与诊断效能,以有创冠状动脉造影为参考标准。结果显示无ECG门控组检查成功率更高,主要诊断效能指标优于ECG门控组,但有效辐射剂量也更高。
要点
- 早搏患者无ECG门控CCTA检查成功率显著高于ECG门控组
- 无ECG门控组患者水平敏感性、阴性预测值及准确性更高
- 无ECG门控组有效辐射剂量略高,需权衡获益与剂量
核心结论
- 对于早搏患者,无ECG门控CCTA可减少心律失常相关伪影,是一种稳健的替代方案
- 无ECG门控CCTA在提高检查成功率和诊断准确性方面具有优势,且总体图像质量未受损
- 无ECG门控CCTA的有效辐射剂量高于ECG门控CCTA,但整体获益风险比仍较好
研究设计与样本
- 本研究纳入416例同时接受CCTA和有创冠状动脉造影检查的早搏患者
- ECG门控组207例,无ECG门控组209例
- 以有创冠状动脉造影为参考标准,狭窄阈值设定为≥50%
- 在患者水平、血管水平和节段水平评估诊断效能
关键影像表现/征象
- ECG门控组中可见心律失常相关伪影导致检查成功率降低
- 无ECG门控组通过减少心律失常相关伪影改善冠脉显示质量
- 两组信噪比和对比噪声比相当,提示客观图像质量未见明显差异
诊断标准与关键数值
- 检查成功率:无ECG门控组92.59% vs ECG门控组74.07%,p<0.001
- 主观图像质量中位评分:无ECG门控组4.00 vs ECG门控组3.50,p<0.001
- 患者水平敏感性:无ECG门控组93.71% vs ECG门控组84.97%,p=0.008
- 患者水平阴性预测值:无ECG门控组71.05% vs ECG门控组42.22%,p=0.009
- 患者水平准确性:无ECG门控组91.39% vs ECG门控组80.19%,p=0.001
临床应用与阅片要点
- 早搏患者可优先考虑无ECG门控CCTA以减少心律失常伪影并提高诊断准确性
- 报告早搏患者CCTA时,无ECG门控组更高的阴性预测值有助于排除冠脉狭窄
- 使用无ECG门控CCTA时需注意有效辐射剂量略高于ECG门控方案
局限性
- 两组有效辐射剂量存在差异,无ECG门控组剂量更高
- 无ECG门控组内进行了时间亚组分析以评估潜在的时间偏倚
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the examination success rate, image quality, and diagnostic performance of coronary computed tomography angiography without versus with external electrocardiographic gating (ECG-less CCTA vs. ECG-gated CCTA) in patients with premature contractions (PCs).
METHODS: This study included 416 patients with PCs who underwent both CCTA and invasive coronary angiography (ICA). The cohort consisted of 207 patients in the ECG-gated group and 209 in the ECG-less group. The groups were compared in terms of examination success rate, subjective image quality (5-point scale), and objective image quality metrics, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Diagnostic performance was evaluated against ICA (stenosis ≥ 50%) at patient, vessel, and segment levels. A chronological subgroup analysis was performed within the ECG-less group to assess potential temporal bias.
RESULTS: Baseline characteristics were well balanced between the groups. The ECG-less group showed a significantly higher examination success rate (92.59% vs. 74.07%, p < 0.001) and superior subjective image quality (median score, 4.00 vs. 3.50; p < 0.001), whereas SNR and CNR were comparable between the groups. At the patient level, sensitivity, negative predictive value, and accuracy were significantly higher in the ECG-less group (93.71% vs. 84.97%, 71.05% vs. 42.22%, and 91.39% vs. 80.19%; p = 0.008, 0.009, and 0.001, respectively). Diagnostic performance at the vessel and segment-levels was also improved (all p < 0.017), except for vessel-level specificity (p = 0.061). The effective radiation dose was higher in the ECG-less group (5.33 mSv vs. 4.35 mSv, p < 0.001). Subgroup analysis revealed no significant temporal differences in the primary outcomes.
CONCLUSION: In patients with PCs, ECG-less CCTA is a robust alternative that improves examination success and diagnostic accuracy by reducing arrhythmia-related artifacts without compromising overall image quality, providing a favorable benefit-risk profile despite a moderate increase in radiation dose.
引用
- Xue, Liu, Ren, et al. Evaluating the imaging performance of ECG-less versus ECG-gated coronary CT angiography in patients with premature contractions. Eur J Radiol. 2026. PMID: 42679414. doi:10.1016/j.ejrad.2026.113178
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。