文献速递胸部技术与安全CT

商用AI对胸部CT肺结节评估阅片时间的影响

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.
PubMed 文献 · Radiology · 2026-01-01

通过多变量Weibull共享脆弱生存模型分析发现,AI应用与报告完成时间缩短相关。调整后中位阅片时间从21.3分钟降至18.2分钟,减少14.6%。

要点

  • 商用AI辅助肺结节评估可缩短常规阅片时间,但对急诊检查反而延长
  • 心胸专科放射科医生获益最大,阅片时间减少25.0%
  • 心电门控胸部CT检查阅片时间减少41.1%,为所有亚组中最大降幅

核心结论

  • 商用AI辅助肺结节评估在真实临床环境中缩短了放射科医生的阅片时间
  • AI应用与报告完成加快相关,调整后风险比为1.17(95% CI: 1.14-1.21; P < .001)

研究设计与样本

  • 研究在三级医疗中心开展,时间跨度为2021年9月至2024年5月
  • 采用多变量参数Weibull共享脆弱生存模型评估AI应用与阅片时间的关联

关键影像表现/征象

  • 急诊科来源的检查在AI应用后中位阅片时间反而增加7.1%(P < .001)
  • 胸科放射科医生阅片时间相对减少25.0%(P < .001),为各阅片角色中最大降幅
  • 心电门控胸部CT检查阅片时间相对减少41.1%(P < .001),为各检查类型中最大降幅

诊断标准与关键数值

  • 调整后中位阅片时间从AI应用前的21.3分钟降至应用后的18.2分钟,减少14.6%(P < .001)
  • AI应用与报告完成加快相关,调整后风险比1.17(95% CI: 1.14-1.21; P < .001)

临床应用与阅片要点

  • AI辅助在常规门诊和住院胸部CT阅片中价值较高,急诊场景需警惕效率下降
  • 不同阅片角色和检查类型间存在显著异质性,提示AI效益需分层评估

局限性

  • 回顾性单中心研究设计,结果外推需谨慎
  • 未报告AI软件的具体名称和版本信息
  • 阅片时间受报告系统、工作流程等混杂因素影响,研究未完全控制

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19 433 patients (mean age, 62 years ± 14.2 [SD]; 21 814 men; 39 323 chest CT examinations, 19 190 pre-AI, and 20 133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20 000-22 000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.