DSA术后静脉流出评分预测急性缺血性卒中功能预后
对156例成功再通的急性缺血性卒中患者,术后立即行DSA并评估皮层静脉显影评分COVES与微循环时间mCCT。结果显示COVES≥4为有利静脉流出,校正后与90天功能独立显著相关。PVO模型AUC为0.882,不劣于mCCT模型,可作为实用预后替代指标。
要点
- 再通成功后应关注DSA静脉期皮层静脉显影情况,而不仅看动脉再通
- COVES≥4提示有利静脉流出,与90天功能独立显著相关
- 术后静脉流出评分预测价值与复杂微循环时间mCCT相当且更易操作
核心结论
- DSA术后静脉流出PVO是急性缺血性卒中成功再通后有效且实用的功能预后替代指标
- PVO对90天功能独立的预测价值与更复杂的mCCT相当
研究设计与样本
- 回顾性队列研究,纳入156例成功再通的急性缺血性卒中患者,中位年龄69岁,男性占44.2%
- 所有患者在成功再通后立即接受标准脑DSA检查,评估mCCT和COVES
关键影像表现/征象
- 基于DSA评估皮层静脉显影评分COVES及微血管脑循环时间mCCT
诊断标准与关键数值
- ROC曲线确定COVES二分类的最佳截点为4,COVES≥4为有利静脉流出
- 多因素分析显示有利PVO与90天功能独立显著相关,校正OR为10.55,95%CI 3.86-28.88,P<0.001
- PVO加入常规模型后AUC从0.816升至0.882,P=0.008,DeLong检验
- PVO模型AUC为0.882,mCCT模型AUC为0.860,两者比较P=0.210
- 主要结局为90天功能独立,定义为改良Rankin量表评分0至2分
临床应用与阅片要点
- 成功再通后即刻DSA应评估静脉期皮层静脉显影,COVES≥4提示预后较好
- 术后静脉流出评分可作为常规模型的补充,用于预测90天功能结局
局限性
- 研究为回顾性队列设计
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Successful recanalization fundamentally reshapes cerebral hemodynamics in acute ischemic stroke (AIS), making preprocedural hemodynamic biomarkers alone inadequate. We assessed postoperative venous outflow (PVO) based on digital subtraction angiography (DSA) and explored its prognostic role. MATERIALS AND METHODS: This retrospective cohort study included AIS patients who achieved recanalization. All patients underwent standard cerebral DSA immediately after successful recanalization. We assessed the microvascular cerebral circulation time (mCCT) and cortical vein opacification score (COVES) based on DSA. The primary outcome was functional independence at 90 days, defined as a modified Rankin Scale score of 0 to 2. Logistic regression and receiver operating characteristic (ROC) analysis were used. RESULTS: 156 patients were included (median age 69 years and 44.2% men). ROC curve analysis determined the optimal cut-off of 4 for COVES dichotomization. Multivariate analysis showed that the favorable PVO (COVES ≥ 4) was significantly associated with functional independence at 90 days (adjusted odds ratio 10.55, 95% confidence interval 3.86-28.88, p < 0.001). After incorporating PVO into the conventional model, the area under the receiver operating characteristic curve increased significantly (0.882 vs. 0.816, p = 0.008, DeLong test) and was not inferior to the mCCT model (0.882 vs. 0.860, p = 0.210). Finally, the PVO model demonstrated good discrimination and calibration, confirmed by fivefold cross-validation. CONCLUSION: The DSA-based PVO after successful recanalization is an effective and practical prognostic surrogate for functional outcomes in AIS, providing predictive value for 90-day functional outcomes comparable to the more complex mCCT.
引用
- Gong, Du, Xiong, et al. DSA-based Postoperative Venous Outflow Serves as a Potential Prognostic Surrogate for Cerebral Microcirculation Time After Recanalization in Acute Ischemic Stroke. Acad Radiol. 2026. PMID: 42680657. doi:10.1016/j.acra.2026.08.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。