文献速递泌尿生殖妇产影像MR

O-RADS MRI:半定量强化曲线提升附件肿块定性效能

Improving diagnostic performance of O-RADS MRI: semi-quantitative intensity curves vs visual assessment of enhancement.
PubMed 文献 · Eur Radiol · 2026-08-30

该回顾性研究纳入两个转诊中心321例女性341个附件肿块,其中35.2%为恶性。比较O-RADS MRI标准视觉评估与半定量强化曲线的诊断效能及手术分流影响。结果显示半定量强化曲线可提高特异度与阳性预测值,并改善良恶性手术分流。

要点

  • O-RADS MRI标准视觉评估敏感度高,适合作为初筛工具。
  • 半定量强化曲线可提高特异度及阳性预测值,减少良性病变由妇科肿瘤医生处理。
  • 半定量曲线解读在不同年资医师间一致性好,便于临床推广。

核心结论

  • O-RADS MRI对附件肿块良恶性分流具有较高诊断效能。
  • 纳入半定量强化曲线可提高O-RADS MRI的特异度与阳性预测值。
  • 半定量强化曲线解读具有较高的观察者间及观察者内一致性。

研究设计与样本

  • 回顾性MRI研究,纳入2008年1月至2018年12月两个转诊中心行手术切除的患者。
  • 共321例女性341个附件肿块,年龄18~89岁。
  • 由两名不同经验放射科医师进行O-RADS MRI评分。
  • O-RADS评分≥4分为可疑恶性。
  • 交界性及浸润性病变判定为恶性。

关键影像表现/征象

  • 标准视觉评估判定O-RADS≥4分时敏感度0.95(CI:0.89–0.98)。
  • 标准视觉评估判定O-RADS≥4分时特异度0.84(CI:0.79–0.89)。
  • 标准视觉评估判定O-RADS≥4分时阳性预测值0.77(CI:0.69–0.83)。

诊断标准与关键数值

  • 应用半定量强化曲线后特异度提高至0.92(CI:0.88–0.95,p=0.007)。
  • 应用半定量强化曲线后阳性预测值提高至0.90(CI:0.83–0.95,p=0.002)。
  • 纳入半定量强化曲线可使良性病变由妇科肿瘤医生手术的比例从16%(54/341)降至9%(1/341)(p=0.0001)。
  • O-RADS评分、半定量强化曲线及视觉评估的观察者间和观察者内一致性Kappa值为0.63–0.85。

临床应用与阅片要点

  • 对含实性成分的附件肿块,建议在O-RADS MRI视觉评估基础上结合半定量强化曲线分析。
  • 半定量强化曲线尤其适用于提高特异度,有助于减少良性病变不必要转诊至妇科肿瘤专业。
  • O-RADS≥4分仍为可疑恶性的核心判读阈值。

局限性

  • 回顾性研究设计可能引入选择偏倚。
  • 仅纳入接受手术切除的病例,可能高估恶性比例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: O-RADS MRI improves differentiation of benign adnexal lesions managed by a gynecologist and malignant lesions managed by a gynecologic oncologist.

OBJECTIVE: To compare O-RADS MRI visual assessment (VA) of mass enhancement with a semi-quantitative intensity curve of enhancement (SIC), a modified manual version of the time intensity curve.

MATERIALS AND METHODS: We conducted a retrospective MRI review of patients who underwent surgical resection between January 2008 and December 2018 at two referral centers. O-RADS MRI score was assigned by two radiologists with different experience. O-RADS score ≥ 4 was considered suspicious for malignancy. Per-lesion diagnostic accuracy and impact on surgical management were compared between VA and SIC in lesions with solid components. Inter/intra-reader agreement was assessed. Borderline and invasive lesions were considered malignant.

RESULTS: Three hundred forty-one adnexal masses in 321 women (ages 18-89) were assessed; 35.2% (120/341) of the masses were malignant. Ninety-six and two-tenths percent had some solid component (329/341). O-RADS MRI using standard VA had a sensitivity, specificity, and PPV of 0.95 (CI: 0.89-0.98), 0.84 (CI: 0.79-0.89), and 0.77 (CI:0.69-0.83), respectively. Use of SIC improved specificity (0.92 [CI: 0.88-0.95, p = 0.007) and PPV (0.90 [CI: 0.83-0.95], p = 0.002). Including SIC in O-RADS MRI would have reduced the proportion of benign lesions operated by gyneoncologists from 16% [54/341] to 9% [1/341] (p = 0.0001). O-RADS score, SIC, and VA assessment had a moderate to high inter- and intra-reader agreement (Kappa 0.63-0.85).

CONCLUSION: O-RADS MRI exhibited high diagnostic performance in triage of adnexal masses. Incorporation of SIC increased the specificity and PPV of O-RADS MRI with high inter- and intra-reader agreement of SIC interpretation.

KEY POINTS: Question Differentiation of benign from malignant adnexal masses is important for surgical triage. Findings Integration of semiquantitative intensity curves (SIC) into O-RADS MRI improved specificity when compared to conventional VA. Clinical relevance Integration of SIC into O-RADS MRI improves surgical triage of patients.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Salinas-Miranda, Nanapragasam, Nasri, et al. Improving diagnostic performance of O-RADS MRI: semi-quantitative intensity curves vs visual assessment of enhancement. Eur Radiol. 2026. PMID: 42668304. doi:10.1007/s00330-026-12742-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。