文献速递心血管CT

低剂量低对比剂CT冠状动脉成像质量与辐射剂量系统综述

Assessment of image quality and radiation dose in low-dose, low-contrast computed tomography coronary angiogram: a systematic review and meta-analysis.
PubMed 文献 · Clin Radiol · 2026-08-06

本系统综述与荟萃分析纳入2014-2025年间PubMed、Scopus和Web of Science中5项研究、共353名受试者,评估低对比剂、低剂量CT冠状动脉成像的图像质量与辐射剂量。结果显示低剂量低对比剂CTCA在保持高图像质量的同时可降低辐射暴露,80 kV与100 kV方案的合并SNR分别为27.1和22.1,合并CNR分别为31.2和24.0。80 kV方案较100 kV辐射剂量降低54-56%,图像质量差异仅为5-15%。

要点

  • 80 kV低剂量低对比剂CTCA辐射剂量较100 kV降低54-56%,图像质量差异仅5-15%。
  • 低剂量低对比剂CTCA需联合迭代重建或深度学习图像重建以维持图像质量。
  • 80 kV方案可在特定患者中作为降低碘负荷和辐射暴露的优选策略。

核心结论

  • 低剂量低对比剂CTCA采用80-100 kV结合迭代或深度学习图像重建可在保持图像质量的同时降低碘对比剂和辐射暴露。
  • 与100 kV相比,80 kV提供更低辐射剂量且图像质量差异极小,支持在特定患者中应用。

研究设计与样本

  • 系统综述与荟萃分析,遵循PRISMA 2020指南,注册于PROSPERO。
  • 检索PubMed、Scopus和Web of Science数据库2014-2025年间文献,评估低对比剂低剂量CTCA的研究。
  • 纳入5项研究,共353名受试者,结局指标包括SNR、CNR、CTDIvol、DLP和ED。
  • 采用留一法敏感性分析和研究内亚组分析评估合并估计值的稳健性。

关键影像表现/征象

  • 80 kV方案合并SNR为27.1(95% CI: 17.85-36.26),合并CNR为31.2(95% CI: 22.21-40.28)。
  • 100 kV方案合并SNR为22.1(95% CI: 10.89-33.25),合并CNR为24.0(95% CI: 15.78-32.19)。
  • 亚组分析显示80 kV较100 kV辐射剂量降低54-56%,SNR和CNR差异为5-15%。

诊断标准与关键数值

  • 80 kV方案CTDIvol为2.08 mGy,DLP为38.8 mGy·cm,ED为0.37 mSv。
  • 100 kV方案CTDIvol为5.59 mGy,DLP为84.8 mGy·cm,ED为1.24 mSv。
  • 80 kV合并SNR为27.1(95% CI: 17.85-36.26),合并CNR为31.2(95% CI: 22.21-40.28)。
  • 100 kV合并SNR为22.1(95% CI: 10.89-33.25),合并CNR为24.0(95% CI: 15.78-32.19)。

临床应用与阅片要点

  • 低剂量低对比剂CTCA可应用于需降低碘负荷和辐射暴露的特定患者群体。
  • 采用80-100 kV管电压时应联合迭代重建或DLIR以保证诊断图像质量。
  • 80 kV方案可作为优先选择,在辐射剂量显著降低的同时图像质量损失有限。

局限性

  • 仅纳入5项研究,总样本量为353名受试者,研究数量较少。
  • 原文未报告纳入研究的中心数、设备类型及具体参考标准。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide. Computed tomography coronary angiography (CTCA), a noninvasive test, requires contrast volume and radiation dose. Low-contrast, low-dose CTCA using reduced tube potential and reconstruction minimises nephropathy and radiation exposure while maintaining quality.

MATERIALS AND METHODS: This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines and was registered with International Prospective Register of Systematic Reviews (PROSPERO); PubMed, Scopus, and Web of Science (2014-2025) databases were searched for studies evaluating low-contrast, low-dose CTCA. Outcomes included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), computed tomography dose index volume (CTDIvol), dose-length product (DLP), and effective dose (ED). Leave-one-out sensitivity and within-study subgroup analyses were performed.

RESULTS: Five studies with 353 participants were analysed. Low-dose, low-contrast CTCA maintains high image quality while reducing radiation exposure. At 80 kV, combined SNR and CNR were 27.1 (95% confidence interval [CI]: 17.85-36.26) and 31.2 (95% CI: 22.21-40.28), respectively, with CTDIvol: 2.08 mGy, DLP: 38.8 mGy·cm, and ED: 0.37 mSv. At 100 kV, combined SNR and CNR were 22.1 (95% CI: 10.89-33.25) and 24.0 (95% CI: 15.78-32.19), respectively, with CTDIvol: 5.59 mGy, DLP: 84.8 mGy·cm, and ED: 1.24 mSv. Subgroup analysis showed an 80-kV reduced radiation dose by 54-56% while keeping image quality similar, with 5-15% difference in SNR and CNR values. The leave-one-out analysis confirmed robustness of the pooled estimates.

CONCLUSION: Low-dose, low-contrast CTCA using 80-100 kV with iterative or deep learning image reconstruction (DLIR) maintains image quality while reducing iodine and radiation exposure. Compared with 100 kV, 80 kV provides lower radiation dose with minimal image-quality differences, supporting use in selected patients.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Naik, Visakh, Prakashini, et al. Assessment of image quality and radiation dose in low-dose, low-contrast computed tomography coronary angiogram: a systematic review and meta-analysis. Clin Radiol. 2026. PMID: 42667811. doi:10.1016/j.crad.2026.107452

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。