CT影像组学能否优于形态学特征诊断卵巢透明细胞癌:多中心研究
本研究纳入457例上皮性卵巢癌患者(训练280例、内部测试69例、外部测试108例),比较传统模型(临床+CT形态学)、影像组学模型及整合模型对卵巢透明细胞癌的诊断效能。结果显示,整合模型在内部和外部测试集中AUC最高,但与传统模型相比无显著统计学差异,影像组学未显著提升AUC。
要点
- 整合模型在内外测试集中敏感度数值最高且更稳定,可能有助于减少漏诊
- 影像组学单独使用敏感度较低(内部测试集75.0%),不宜作为独立诊断依据
- 传统CT形态学模型诊断效能与整合模型接近,日常阅片应重视形态学征象
核心结论
- 在这项多中心头对头比较中,影像组学未能显著提升卵巢透明细胞癌诊断的AUC
- 整合模型在内外测试集中敏感度数值更高且更稳定,提示在减少漏诊和避免无效新辅助化疗方面有潜在临床价值
- 影像组学模型与传统模型的AUC差异在各测试集中均未达到统计学显著水平
研究设计与样本
- 多中心回顾性研究,纳入457例上皮性卵巢癌患者,其中96例(21%)为卵巢透明细胞癌
- 样本划分:训练集280例、内部测试集69例、外部测试集108例
- 两名放射科医师评估10个CT形态学特征,从CT图像提取1218个影像组学特征
- 影像组学特征经ICC≥0.8筛选后进行JMIM特征选择,构建Logistic回归模型
关键影像表现/征象
- 影像组学评分与多个CT形态学特征存在显著相关性
诊断标准与关键数值
- 内部测试集:整合模型AUC 0.890,传统模型AUC 0.840(p=0.210),影像组学模型AUC 0.811(p=0.051)
- 内部测试集敏感度:整合模型和传统模型均为100%,影像组学模型为75.0%
- 外部测试集:整合模型AUC 0.850,传统模型AUC 0.837(p=0.645),影像组学模型AUC 0.809(p=0.102)
- 外部测试集敏感度:整合模型81.8%,传统模型77.3%,影像组学模型81.8%
- 传统模型由临床变量与CT形态学特征构成,影像组学模型输出为影像组学评分,整合模型为两者结合
临床应用与阅片要点
- CT形态学特征仍是诊断卵巢透明细胞癌的重要依据,阅片时应系统评估形态学征象
- 整合模型敏感度数值更高且跨队列稳定,可辅助减少漏诊和避免无效新辅助化疗
- 影像组学评分与形态学特征显著相关,提示影像组学可能部分反映形态学信息而非完全独立的增量信息
局限性
- 回顾性研究设计,外部测试集样本量有限,需更大前瞻性队列进一步验证
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Platinum-resistant OCCC misdiagnosis risks ineffective chemotherapy. CT morphology is widely used for diagnosis, and our prior single-center study showed radiomics is feasible. Whether radiomics adds value beyond morphology remains unclear. This multicenter study compares CT, radiomics, and integrated models for OCCC diagnosis.
METHODS: 457 patients with epithelial ovarian cancer (training = 280, internal testing = 69, external testing = 108). Two radiologists assessed 10 CT morphological features. From CT, 1,218 radiomic features were ICC-filtered (≥ 0.8) + JMIM selection. Three logistic regression models were built: traditional (clinical + CT morphology), radiomics (selected features, output as rad-score), and integrated (traditional + rad-score). Performance was evaluated using ROC analysis, and rad-score correlation with morphological features was examined.
RESULTS: Of 457 patients, 96 (21%) had OCCC. In internal testing set, the integrated model achieved the highest AUC (0.890) but was not significantly superior to the traditional model (0.840, p = 0.210) or the radiomics model (0.811, p = 0.051); both integrated and traditional models had 100% sensitivity versus 75.0% for radiomics. In external testing, the integrated model maintained an AUC of 0.850, compared with 0.837 for the traditional model (p = 0.645) and 0.809 for the radiomics model (p = 0.102); sensitivity was 81.8%, 77.3%, and 81.8%, respectively. The rad-score significantly correlated with multiple CT morphological features.
CONCLUSIONS: In this multicenter head-to-head comparison, radiomics did not significantly improve AUC over traditional CT features for OCCC diagnosis. Although sensitivity differences between models were not statistically significant, the integrated model achieved numerically higher and more stable sensitivity across both cohorts, suggesting potential clinical value in reducing missed diagnoses and avoiding ineffective neoadjuvant chemotherapy. These findings warrant further validation in larger prospective cohorts.
引用
- Ren, Yuan, Wu, et al. Can radiomics outperform CT morphological features in diagnosing ovarian clear cell carcinoma? A multicenter study. Abdom Radiol (NY). 2026. PMID: 42658253. doi:10.1007/s00261-026-05745-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。