文献速递神经外周血管CT

PCD-CTA与EID-CTA对头颈部动脉凸起检出及定性的比较

Detection and Characterization of Infundibula and Aneurysms: A Clinical Report-Based Comparison of PCD- and EID-CTA.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-08-25

本研究回顾性纳入29例在2年内先后接受EID-CTA与PCD-CTA头颈血管成像且任一报告描述动脉凸起的成人,共评价42处凸起。结果显示,PCD-CTA可更精细地定性动脉瘤、漏斗部及假性病变,病灶总一致率57%,患者总一致率48%。PCD-CTA或可优化未破裂动脉瘤的随访与治疗决策,并减少漏斗部及假性病变的不必要检查。

要点

  • PCD-CTA空间分辨率更高,用于头颈CTA常能检出或定性EID-CTA漏报、不确定的动脉凸起。
  • EID-CTA不确定的病灶在PCD-CTA上多被重新分类,包括动脉瘤、漏斗部和假性病变。
  • 多发病灶患者两种检查的判读一致性低于单发病灶患者,报告时需格外谨慎。

核心结论

  • PCD-CTA较EID-CTA更常检出并定性动脉瘤及漏斗部,可减少漏斗部和假性病变带来的不必要检查。

研究设计与样本

  • 回顾性配对影像报告比较研究,纳入29例成人、42处头颈部动脉凸起,患者在2周内先后完成EID-CTA与PCD-CTA。
  • 排除既往已治疗病灶及EID-CTA层厚大于0.6 mm者;PCD-CTA参数为120 kV、120×0.2 mm准直、Hv56-3核、0.2 mm层厚。
  • 依据临床报告将病灶分为动脉瘤、漏斗部、不确定、假性病变或未识别,并采用每病灶和每患者两种方式评估一致性。

关键影像表现/征象

  • 共42处动脉凸起,其中8处仅在PCD-CTA报告中描述而EID-CTA未描述,包括4个动脉瘤、3个漏斗部、1个不确定病灶。
  • EID-CTA上9个不确定病灶中,6个在PCD-CTA被重新分类,包括2个动脉瘤、2个漏斗部、2个假性病变。
  • 2个假性病变在PCD-CTA上分别源于重叠血管和钙化,提示高分辨率CTA有助于区分血管出袢与真性病变。
  • EID-CTA报告的24个动脉瘤中,4个在PCD-CTA被重新分类,其中2个为漏斗部、2个为不确定。

诊断标准与关键数值

  • 每病灶一致率为57%(24/42);每患者一致率为48%(14/29)。
  • 多发病灶患者的不一致率(78%,7/9)高于单发病灶患者(40%,8/20)。
  • 8处PCD-CTA额外报告的凸起中,EID-CTA未描述的比例为19%(8/42)。

临床应用与阅片要点

  • 日常头颈CTA阅片中,遇到EID-CTA上不确定的动脉凸起时,可考虑PCD-CTA进一步区分动脉瘤、漏斗部或假性病变。
  • PCD-CTA对重叠血管和钙化造成的假性病变鉴别能力更高,可避免不必要随访。
  • 多发病灶患者两种方法一致性较低,报告的随访建议应结合病灶数目和检查方式审慎给出。

局限性

  • 回顾性设计,样本量较小,仅基于临床报告而非独立影像复核。
  • 两种检查平均间隔约320天,病灶形态可能发生真实变化。
  • 仅纳入有动脉凸起报告的患者,存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Photon-counting detector CT angiography (PCD-CTA) offers higher spatial resolution than energy-integrating detector CTA (EID-CTA), but its impact on clinical reporting of arterial outpouchings in head/neck CTA is unknown. We compared paired EID-CTA and PCD-CTA reports for concordance in lesion detection and characterization (aneurysm vs infundibulum vs uncertain).

MATERIALS AND METHODS: We retrospectively identified adults with paired head and neck PCD-CTA and prior EID-CTA within 2 years in which either report described an arterial outpouching. Exclusions included previously treated lesions and EID-CTA slice thickness >0.6 mm. PCD-CTA used 120 kV, 120×0.2 mm collimation, Hv56-3 kernel, and 0.2 mm slices. Lesions were categorized based on clinical reports as aneurysm, infundibulum, uncertain, pseudo-lesion, or not identified. Concordance was assessed per-lesion and per-patient.

RESULTS: Twenty-nine patients (mean age 658±15 years; 72% female) with 42 outpouchings were included. Mean interval between scans was 320 days. Per-lesion concordance was 57% (24/42). Eight outpouchings (19%) reported on PCD-CTA were not described on EID-CTA, including 4 aneurysms, 3 infundibula, and 1 uncertain lesion. Of 9 EID-CTA uncertain lesions, PCD-CTA reclassified 6 (2 aneurysms, 2 infundibula, 2 pseudo-lesions (one from overlapping vessels and one from calcification). Of 24 EID-CTA aneurysms, 4 were reclassified on PCD-CTA (2 infundibula, 2 uncertain). Per-patient concordance was 48% (14/29); discordance was higher in multi-lesion (78%, 7/9) than single-lesion patients (40%, 8/20).

CONCLUSIONS: PCD-CTA frequently detected/reported aneurysms and infundibula not seen or incompletely characterized on EID-CTA. Routine PCD-CTA for head/neck CTA may refine surveillance and treatment decisions for unruptured aneurysms while reducing unnecessary workup of infundibula and pseudo-lesions.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Jacobson, El Sadaney, Yu, et al. Detection and Characterization of Infundibula and Aneurysms: A Clinical Report-Based Comparison of PCD- and EID-CTA. AJNR Am J Neuroradiol. 2026. PMID: 42642209. doi:10.3174/ajnr.A9607

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。