IOTA-SR 与 O-RADS 在儿童附件病变超声分类中的诊断效能比较

Performance of International Ovarian Tumor Analysis Simple Rules and Ovarian-Adnexal Reporting and Data System for classifying benign and malignant pediatric adnexal lesions using ultrasound.
PubMed 文献 · Pediatr Radiol · 2026-08-22

回顾性纳入 431 例儿童附件病变(平均直径 7.8 cm),比较 IOTA-SR 与 O-RADS 的分类性能。总体及 <10 cm 病变中两者诊断效能相近(AUC 0.910 vs 0.908);对 ≥10 cm 病变,IOTA-SR 优于 O-RADS(AUC 0.921 vs 0.835)。建议大病灶优先采用 IOTA-SR。

要点

  • ≥10 cm 附件病变,IOTA-SR 风险分层优于 O-RADS。
  • O-RADS 5 类恶性风险在 ≥10 cm 为 95.8%,<10 cm 为 63.6%。
  • 两者均可用于儿童,小病灶任选其一即可。

核心结论

  • O-RADS 和 IOTA-SR 对儿童附件病变均显示可接受的诊断性能。
  • IOTA-SR 在大病灶(≥10 cm)分层中优于 O-RADS,此类病例可能更合适。

研究设计与样本

  • 回顾性单中心研究,纳入 2015 年 1 月至 2025 年 1 月三级转诊医院确诊的 431 例儿童附件病变(每例一个病灶)。
  • 患儿平均年龄 15.0 岁,病灶平均直径 7.8 cm,按 O-RADS 和 IOTA-SR 分类,不确定病例由专家复核。
  • 参考标准为病理或临床确认,比较总体及按病灶大小(≥10 cm 与 <10 cm)分组的诊断性能。

关键影像表现/征象

  • 总体 AUC:O-RADS 0.910,IOTA-SR 0.908,差异无统计学意义(P=0.920)。
  • <10 cm 病灶 AUC:O-RADS 0.906,IOTA-SR 0.880,差异无统计学意义(P=0.464)。
  • ≥10 cm 病灶 AUC:O-RADS 0.835,IOTA-SR 0.921,差异有统计学意义(P=0.023)。
  • 最高风险类别中恶性风险估计:O-RADS 5 类在 ≥10 cm 为 95.8%,<10 cm 为 63.6%(P=0.026);IOTA-SR 恶性分类在 ≥10 cm 为 95.7%,<10 cm 为 66.7%(P=0.038)。

诊断标准与关键数值

  • O-RADS 5 类:≥10 cm 病灶恶性风险 95.8%,<10 cm 为 63.6%,差异 P=0.026。
  • IOTA-SR 恶性分类:≥10 cm 病灶恶性风险 95.7%,<10 cm 为 66.7%,差异 P=0.038。
  • 总体 AUC 比较:O-RADS vs IOTA-SR = 0.910 vs 0.908,P=0.920。
  • <10 cm AUC 比较:O-RADS vs IOTA-SR = 0.906 vs 0.880,P=0.464。
  • ≥10 cm AUC 比较:O-RADS vs IOTA-SR = 0.835 vs 0.921,P=0.023。

临床应用与阅片要点

  • 对儿童附件病变,<10 cm 病灶可使用 O-RADS 或 IOTA-SR。
  • ≥10 cm 病灶优先采用 IOTA-SR 以优化风险分层。
  • 报告时可注明所用系统及最高风险类别,便于临床决策。

局限性

  • 回顾性单中心研究,可能限制普遍性。
  • 该研究未提供更多设计局限信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The International Ovarian Tumor Analysis Simple Rules (IOTA-SR) and Ovarian-Adnexal Reporting and Data System (O-RADS) are established tools for adult adnexal lesions but lack pediatric validation.

OBJECTIVE: To assess the diagnostic performance of IOTA-SR and O-RADS for malignant adnexal lesions in children.

MATERIALS AND METHODS: In this retrospective study, pediatric patients with confirmed adnexal lesions at a tertiary referral hospital between January 2015 and January 2025 were included. All lesions were classified according to O-RADS and IOTA-SR, with expert review for inconclusive cases. Diagnostic performance, including sensitivity, specificity, predictive values, accuracy, and area under the receiver operating characteristic curve (AUC), was evaluated and compared between lesion-size subgroups (≥10 cm vs. <10 cm).

RESULTS: A total of 431 adnexal lesions (mean diameter 7.8 cm) from 431 pediatric patients (one lesion per patient, mean age 15.0 years) were analyzed. The estimated malignancy risk in the highest-risk category was significantly greater in lesions ≥10 cm than in smaller lesions for both systems (O-RADS 5: 95.8% vs. 63.6%, P=0.026; IOTA-SR malignant classification: 95.7% vs. 66.7%, P=0.038). Overall and for lesions <10 cm, O-RADS and IOTA-SR demonstrated high and comparable diagnostic performance (overall AUC: 0.910 vs. 0.908, P=0.920; <10 cm AUC: 0.906 vs. 0.880, P=0.464). However, for lesions ≥10 cm, the AUC of O-RADS was significantly lower than that of IOTA-SR (0.835 vs. 0.921, P=0.023).

CONCLUSIONS: Both O-RADS and IOTA-SR show acceptable diagnostic performance for pediatric adnexal lesions. IOTA-SR outperforms O-RADS in stratifying large lesions (≥10 cm) and may be preferable in such cases, while either system can be used effectively for smaller lesions.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Fu, Zhang, et al. Performance of International Ovarian Tumor Analysis Simple Rules and Ovarian-Adnexal Reporting and Data System for classifying benign and malignant pediatric adnexal lesions using ultrasound. Pediatr Radiol. 2026. PMID: 42631735. doi:10.1007/s00247-026-06757-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。