文献速递胸部DRCT

AI辅助胸片诊断的前瞻性交叉多阅片者研究

Artificial Intelligence-Assisted Chest Radiography: A Prospective Crossover Multi-Reader Study on Diagnostic Performance and Workflow Efficiency.
PubMed 文献 · Acad Radiol · 2026-08-21

本研究为前瞻性单中心交叉阅片者研究,5名住院医师评估1200例连续胸片患者的1861幅图像,在无AI及使用4种商用AI算法的条件下判断肺部浸润、胸腔积液、纵隔肿块、气胸和肺结节。结果显示AI辅助未提高诊断准确性,胸腔积液和肺结节的准确性因假阳性增加而下降,但缩短了阅片时间、提高了诊断信心并减少了部分会诊升级。

要点

  • AI辅助胸片诊断未提高准确性,部分征象因假阳性增加反而下降
  • 多数阅片者报告阅片时间缩短(每例中位减少6–17秒)且信心提高
  • 应用AI前需本地化调试以避免自动化偏倚并保持准确性

核心结论

  • 商用AI工具未提高胸片诊断准确性,部分征象因假阳性增多而降低准确性
  • AI可缩短阅片时间、提高诊断信心并减少部分情况下的升级处理

研究设计与样本

  • 前瞻性、单中心、交叉阅片者设计,5名阅片者(经验1–6年)评估1200例连续胸片患者的1861幅图像
  • 五种读片条件:无AI及使用四种商用AI算法分别读片,洗脱期14天,病例顺序随机化
  • 参考标准为最终临床报告,有CT时以CT确认为补充

关键影像表现/征象

  • AI辅助下胸腔积液和肺结节的假阳性增加导致若干阅片者-工具配对的准确性下降

诊断标准与关键数值

  • 阅片时间缩短:5名住院医师中3名报告每例中位减少6至17秒(p≤0.031)
  • 5名阅片者中4名报告诊断信心提高(5分Likert量表)
  • 选定的阅片者-工具配对中高级医师会诊减少,1例CT升级减少

临床应用与阅片要点

  • 应用商用AI胸片工具时需注意自动化偏倚风险,防止因假阳性导致误判
  • 部署前应进行本地化调试以保持准确性并实现效率提升
  • 诊断信心可能被AI不当提高,报告时仍需以影像征象和临床信息为最终依据

局限性

  • 本研究为单中心设计
  • 阅片者均为住院医师(经验1–6年)

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the impact of four commercially available AI solutions for chest radiography on diagnostic performance, workflow efficiency, and clinical decision-making in a real-world setting.

MATERIALS AND METHODS: In this prospective, monocentric, crossover reader study, five readers (one to six years of experience) assessed 1200 consecutive patients undergoing chest radiography (1861 total radiographs) for pulmonary infiltrates, pleural effusions, mediastinal masses, pneumothorax, and pulmonary nodules under five conditions: without AI and with each of four AI algorithms. A 14-day washout period separated sessions, and case order was randomized. The reference standard was the finalized clinical report, supplemented by confirmatory CT when available. The primary outcome was diagnostic performance. Secondary outcomes included interpretation time, diagnostic confidence (5-point Likert scale), escalation to senior review, and CT recommendations.

RESULTS: AI assistance did not improve diagnostic accuracy. For pleural effusions and pulmonary nodules, accuracy decreased in several reader-tool pairings due to increased false positives. However, workflow benefits were observed: three of five residents reported shorter interpretation times, with median reductions of 6 to 17 s per case (p≤0.031). Four of five readers reported higher diagnostic confidence. AI support reduced senior consultations in selected pairings and, in one case, lowered CT escalation.

CONCLUSION: Commercial AI tools did not improve diagnostic accuracy and, for some findings, reduced it through increased false positives, while shortening reading time, increasing confidence, and lowering escalation. These results suggest that to avoid automation bias, maintain accuracy, and achieve efficiency gains, AI deployment requires careful local adaptation. Additionally, clinical trials are necessary to address patient outcomes.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Lemke, Marka, Prucker, et al. Artificial Intelligence-Assisted Chest Radiography: A Prospective Crossover Multi-Reader Study on Diagnostic Performance and Workflow Efficiency. Acad Radiol. 2026. PMID: 42629289. doi:10.1016/j.acra.2026.08.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。