多平面体素序列联合预脉冲的3D MRCP:图像质量与呼吸运动稳健性改善
本回顾性研究纳入50例疑诊胰胆疾病患者,在1.5T MR上比较MPV-MRCP与常规3D MRCP和屏气MRCP的图像质量。结果显示MPV-MRCP的SNR及总体图像质量评分显著更高,近端胰管显示更佳,呼吸运动相关伪影更轻。
要点
- MPV-MRCP在呼吸不规律或屏气能力差的患者中可作为替代选择。
- MPV-MRCP对近端胰管显示优于常规技术,阅片时可优先观察该序列。
核心结论
- MPV-MRCP相比C-MRCP和BH-MRCP可改善图像质量和胰管显示。
- MPV-MRCP尤其适用于屏气能力有限或呼吸不规律的患者。
研究设计与样本
- 回顾性研究,纳入50例因胰胆疾病接受MRCP检查的患者。
- 所有检查均在1.5T MRI扫描仪上完成,比较MPV-MRCP、C-MRCP与BH-MRCP三种序列。
- 由两名放射科医师采用标准化评分系统独立评估图像质量和胰胆管显示。
- 统计方法包括Kruskal-Wallis检验及post hoc比较,观察者间一致性采用加权κ统计。
关键影像表现/征象
- MPV-MRCP在所有患者中均成功完成采集。
- MPV-MRCP在定性评估中显示更轻的呼吸运动相关图像质量下降。
- MPV-MRCP对近端胰管显示优于C-MRCP和BH-MRCP。
诊断标准与关键数值
- MPV-MRCP的SNR显著高于C-MRCP和BH-MRCP(p<0.01)。
- 三种序列间的对比度比(CR)无显著差异。
- MPV-MRCP总体图像质量评分显著高于C-MRCP和BH-MRCP(p<0.01)。
临床应用与阅片要点
- 对屏气配合欠佳的患者,MPV-MRCP可作为提高胰胆管成像成功率的备选序列。
- 关注近端胰管病变时,MPV-MRCP可能提供更清晰的显示。
局限性
- 回顾性研究设计。
- 样本量为50例。
- 单中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the feasibility of magnetic resonance cholangiopancreatography (MRCP) using a multi-planar voxel (MPV) sequence combined with a pre-contrast pulse (MPV-MRCP) and to compare its image quality with conventional three-dimensional MRCP (C-MRCP) and breath-hold MRCP (BH-MRCP).
MATERIALS AND METHODS: In this retrospective study, MRCP images from 50 patients who underwent evaluation for pancreaticobiliary disease were analyzed. All examinations were performed using a 1.5-T MRI scanner. Quantitative assessments included signal-to-noise ratio (SNR) and contrast ratio (CR). Qualitative image quality and duct visualization were independently evaluated by two radiologists using standardized scoring systems. Statistical analysis was performed using the Kruskal-Wallis test with post hoc comparisons and weighted κ statistics for interobserver agreement.
RESULTS: MPV-MRCP was successfully acquired in all patients. It demonstrated significantly higher SNR compared with both C-MRCP and BH-MRCP (p < 0.01), while no significant differences in CR were observed. MPV-MRCP achieved significantly higher overall image quality scores and improved visualization of the proximal pancreatic duct (p < 0.01). Additionally, MPV-MRCP demonstrated less apparent respiratory motion-related image degradation on qualitative assessment.
CONCLUSION: MPV-MRCP improves image quality and duct visualization compared with conventional MRCP techniques and may serve as a clinically valuable alternative, particularly in patients with limited breath-holding ability or irregular respiration.
引用
- Ayabe, Hamamoto, Chiba, et al. Three-dimensional MRCP technique using a multi-planar voxel sequence combined with a precontrast pulse: improved image quality and robustness to respiratory motion. Abdom Radiol (NY). 2026. PMID: 42622830. doi:10.1007/s00261-026-05744-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。