Mini-CABG术前CT评估侧肋动脉的临床意义
该研究纳入126例CABG术前接受胸部CTA的患者,评估侧肋动脉(LCA)的存在、直径、长度及LCA/IMA比值。LCA阳性率为10.3%,其中8%的mini-CABG患者存在LCA;术后随访未见LCA阳性mini-CABG患者记录到LAD供血区缺血症状。研究效能不足,LCA临床意义仍不确定。
要点
- 胸部CTA可显示LCA,报告时可描述其存在、直径及与IMA关系
- LCA阳性率为10.3%,mini-CABG患者中为8%
- 本组LCA阳性mini-CABG患者术后未见记录的LAD区缺血症状
核心结论
- LCA阳性mini-CABG患者在电子病历中未见记录的LAD供血区缺血症状
- 该研究效能不足以检验LCA与术后LAD供血区缺血的关联
- LCA的临床意义尚不确定,需更大样本研究进一步明确
研究设计与样本
- 回顾性队列研究,纳入2015年1月1日至2021年9月30日CABG术前接受胸部CTA或心脏CTA的患者126例
- 研究分析CTA图像质量、LCA存在、直径、LCA/IMA比值及长度
- 查阅手术记录确认术中LCA结扎情况,术后通过病历回顾随访至CABG后8年
关键影像表现/征象
- LCA存在于13例患者(10.3%),单侧5例(38%),双侧8例(62%)
- 62例(49%)接受mini-CABG,其中5例(8%)为LCA阳性
- LCA平均直径为1.4±0.2mm,IMA平均直径为3.5±0.3mm
- LCA/IMA平均比值为0.4±0.06,LCA平均长度为79±20.6mm
诊断标准与关键数值
- LCA直径、LCA/IMA比值及长度采用CTA测量,敏感度、特异度和AUC未报告
临床应用与阅片要点
- 术前胸部CTA阅片时应主动观察并报告LCA的有无、直径、长度及其与IMA的关系
- LCA阳性患者在mini-CABG术后本组未见记录的LAD供血区缺血症状,但仍应关注相关病史
局限性
- 该研究为回顾性设计,且样本量不足以检测LCA与术后LAD供血区缺血的关联
- 术后缺血症状依赖电子病历记录,可能存在记录不完整或无症状未就诊的情况
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The left internal mammary artery (IMA) is the gold standard in coronary artery bypass grafting (CABG) to the left anterior descending (LAD) coronary artery. The presence of the lateral costal artery (LCA) has been identified as the culprit for post-operative steal phenomenon in some patients. Direct ligation of LCA in minimally invasive CABG (mini-CABG) may be challenging due to limited surgical access. This study aims to evaluate the presence, length, and size of the LCA and to determine whether it plays a role in LAD territory ischemia after mini-CABG.
MATERIAL AND METHODS: All patients who underwent contrast-enhanced chest imaging (CTA, cardiac CTA) prior to CABG from January 1, 2015 to September 30, 2021 were included. CTA studies were analyzed for image quality, LCA presence, diameter, LCA/IMA ratio and length. Operative reports were reviewed for intraoperative LCA ligation. Postoperative follow-up was performed up to 8 years after CABG procedure by chart review for symptoms of LAD territory ischemia suggestive of steal phenomenon.
RESULTS: The cohort consisted of 126 patients (64.5 ± 10y). LCA was present in 13 patients (10.3 %), unilateral in 5 (38 %) patients and bilateral in 8 patients (62 %). 62 (49 %) patients underwent mini-CABG where 5 (8 %) were positive for LCA. The mean LCA diameter was 1.4 ± 0.2 mm and the average IMA diameter measured 3.5 ± 0.3 mm. The mean LCA/IMA ratio was 0.4 ± 0.06 , and the average LCA length was 79 ± 20.6 mm. No LCA positive mini-CABG patients had documented symptoms of postoperative LAD-territory ischemia or symptoms suggestive of coronary steal phenomenon during follow-up. Two patients after regular CABG presented with angina within the first month after CABG, but this was attributed to non-coronary causes.
CONCLUSION: The LCA was visualized with CTA in patients before undergoing CABG including mini-CABG. LCA positive patients after mini-CABG showed no documented symptomatic LAD-territory ischemia in electronic patient records. The analysis was underpowered to detect an association between presence of LCA and potential postoperative LAD territory ischemia. The clinical significance of LCA remains uncertain and requires further studies with larger cohorts to clarify the clinical implications of LCA in patients undergoing mini-CABG.
引用
- Alsaedi, Maroun, Streit, et al. Lateral costal artery assessment in patients undergoing Mini-CABG procedure. Exploratory assessment of the potential clinical significance of LCA in Mini-CABG patients. Eur J Radiol. 2026. PMID: 42623985. doi:10.1016/j.ejrad.2026.113171
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。