文献速递神经MR

IVIM 生境成像术前预测弥漫中线胶质瘤 H3 K27 状态

Preoperative Prediction of H3 K27 Alteration Status in Diffuse Midline Glioma Using Intravoxel Incoherent Motion Imaging-based Habitat Imaging.
PubMed 文献 · Acad Radiol · 2026-08-20

本回顾性研究纳入 153 例弥漫中线胶质瘤患者(126 例成人),均行 IVIM 检查。研究基于灌注分数与真扩散系数图将肿瘤分为三个生境,比较各生境定量参数并构建临床、生境及混合预测模型。混合模型预测 H3 K27 改变状态的 AUC 最高,达 0.900,且其预测分组与总生存期显著相关。

要点

  • H3 K27 改变型 DMG 的生境 2、生境 3 的 f 值及生境 3 体积均显著高于野生型
  • 混合模型预测 H3 K27 状态 AUC 达 0.900,优于单纯临床模型和生境模型
  • 只有混合模型预测的 H3 K27 改变组与野生型组总生存期差异有统计学意义

核心结论

  • 基于 IVIM 的生境成像可无创预测弥漫中线胶质瘤 H3 K27 改变状态,且预测结果与预后相关

研究设计与样本

  • 回顾性研究,纳入 153 例弥漫中线胶质瘤患者,其中 126 例成人,均接受 IVIM 检查
  • 根据 H3 K27 状态分为 H3 K27 改变组和 H3 K27 野生型组
  • 基于灌注分数图和真扩散系数图将肿瘤划分为三个生境:生境 1 为低扩散低灌注,生境 2 为高扩散低灌注,生境 3 为高灌注
  • 使用 logistic 回归筛选风险因素,分别构建临床模型、生境模型和混合模型

关键影像表现/征象

  • H3 K27 改变型 DMG 与野生型相比,生境 2 和生境 3 的 f 值显著更高
  • H3 K27 改变型 DMG 的生境 3 体积显著大于野生型
  • 年龄、瘤周无强化模式及生境指标被筛选为构建诊断模型的风险因素

诊断标准与关键数值

  • 混合模型诊断 H3 K27 改变状态的 AUC 为 0.900,临床模型 AUC 为 0.860,生境模型 AUC 为 0.716
  • H3 K27 改变组与野生型组在生境 2、生境 3 的 f 值和生境 3 体积上的差异均 p < 0.05
  • 混合模型预测的 H3 K27 改变组与野生型组总生存期差异 p = 0.043

临床应用与阅片要点

  • 阅片时可将 DMG 病灶在 IVIM 上按扩散与灌注特征划分生境,重点关注高灌注生境的 f 值和体积
  • 预测 H3 K27 状态时建议结合年龄、瘤周强化模式与生境参数,而非仅依靠单一模型

局限性

  • 回顾性研究设计

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The H3 K27 alteration status of diffuse midline gliomas (DMGs) is critical for prognosis and therapeutic decision-making but currently relies on invasive tissue sampling.

MATERIALS AND METHODS: 153 patients (126 adults) with DMG who underwent intravoxel incoherent motion (IVIM) examinations were retrospectively included. DMGs were divided into H3 K27-altered (H3 K27-A) and wild-type (H3 K27-WT) groups. The DMGs were divided into three habitats (habitat 1-low diffusion and perfusion, habitat 2 -high diffusion and low perfusion, habitat 3-high perfusion) based on perfusion fraction and true diffusion coefficient maps. The quantitative parameters of each habitat were compared. The logistic regression was used to select risk factors. The clinical, habitat, and hybrid models were constructed using identified risk factors from clinical characteristics, habitat metrics, and their combination, respectively. The diagnostic performance and overall survival (OS) were analyzed.

RESULTS: Compared with H3 K27-WT tumors, H3 K27-A DMGs had significantly higher f value in habitat 2 and habitat 3, and a larger volume of habitat 3 (all p < 0.05). The age, peritumoral nonenhanced pattern, and habitat metrics were selected as risk factors for constructing diagnostic models. The hybrid model achieved the highest diagnostic performance (area under the curve (AUC) = 0.900), followed by the clinical model (AUC = 0.860) and habitat model (AUC = 0.716). Only the predicted H3 K27-A group by the hybrid model showed significantly different OS compared with the H3 K27-WT group (p = 0.043).

CONCLUSION: IVIM-based habitat imaging can noninvasively predict the H3 K27 alteration status of DMG with high accuracy, which is associated with prognosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Guo, Su, Pan, et al. Preoperative Prediction of H3 K27 Alteration Status in Diffuse Midline Glioma Using Intravoxel Incoherent Motion Imaging-based Habitat Imaging. Acad Radiol. 2026. PMID: 42624734. doi:10.1016/j.acra.2026.08.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。