儿童急性侵袭性真菌性鼻窦炎的CT诊断准确性
本研究回顾性评估鼻窦CT对儿童急性侵袭性真菌性鼻窦炎(AIFRS)的诊断准确性,共纳入106例高危患儿,40例确诊AIFRS。以手术活检和/或临床随访为金标准,一处及以上CT异常诊断AIFRS的敏感度为83%,特异度为97%,AUC为0.9。CT特异度高于敏感度,鼻内镜仍是临床高度怀疑而CT阴性时的诊断金标准。
要点
- 儿童AIFRS最常见危险因素是白血病,鼻甲和鼻中隔为最常见受累部位。
- 一处及以上CT异常诊断AIFRS的敏感度83%,特异度97%,AUC为0.9。
- 17.5%的AIFRS患儿CT未检出,最常见漏诊部位为中鼻甲,CT阴性不能排除AIFRS。
核心结论
- 鼻窦CT对儿童AIFRS总体诊断准确性为中等至高水平,特异度高于敏感度。
- 相当数量儿童鼻腔AIFRS未被CT识别,临床仍高度怀疑时鼻内镜是诊断金标准。
研究设计与样本
- 回顾性研究,纳入106例有AIFRS风险的儿童,平均年龄9.4岁。
- 对鼻窦CT进行多解剖部位评估,关注软组织与骨质异常。
- 以手术活检和/或临床随访为金标准计算窦CT诊断AIFRS的准确性。
关键影像表现/征象
- 鼻甲和鼻中隔是AIFRS最常见受累部位。
- 17.5%的AIFRS患儿CT未检出,漏诊最常见部位为中鼻甲。
诊断标准与关键数值
- 一处及以上CT异常诊断AIFRS的敏感度为83%,特异度为97%,AUC为0.9。
- 面部症状、中性粒细胞绝对计数低于500持续时间、低于200持续时间在AIFRS阳性与阴性患儿间差异有统计学意义(p<0.001;p=0.02;p=0.01)。
临床应用与阅片要点
- 儿童鼻窦CT阴性而临床高度怀疑AIFRS时,应进一步行鼻内镜检查以免漏诊。
- 阅片时应重点观察鼻甲和鼻中隔区域软组织与骨质异常。
局限性
- 回顾性研究设计存在固有局限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this research was to determine the diagnostic accuracy of CT imaging of the paranasal sinuses for the diagnosis of acute invasive fungal rhinosinusitis (AIFRS) in children.
METHODS: A retrospective review of sinus CTs performed in patients at risk for AIFRS was performed. A multi-anatomic site evaluation of CT imaging was performed with attention to soft tissue and bone abnormalities. Diagnostic accuracy of sinus CT findings was calculated for diagnosis of AIFRS with gold standard obtained from surgical biopsy and/or clinical follow-up.
RESULTS: A total of 106 pediatric patients were included with a mean age was 9.4 years. The most common clinical risk factor for AIFRS was leukemia. A total of 40 children were diagnosed with AIFRS. The nasal turbinates and nasal septum were the most common sites of disease. Presence of facial symptoms, duration of ANC < 500, and duration of ANC < 200 were significantly different in AIFRS (+) versus AIFRS (-) patients (p<0.001; p=0.02; p=0.01). The sensitivity, specificity, and AUC for diagnosis of AIFRS from one or more abnormal CT findings were 83%, 97%, and 0.9 respectively. A total of seven patients (17.5%) with AIFRS were not detected by CT imaging, and the most common site of missed AIFRS was at the middle turbinate.
CONCLUSION: CT imaging of the sinuses demonstrates moderate to high level of overall diagnostic accuracy for AIFRS, but with greater specificity than sensitivity. AIFRS in the nasal cavity was not identified by CT in a substantial number of children such that nasal endoscopy remains the diagnostic gold standard in the setting of a negative sinus CT when the clinical concern for AIFRS remains.
引用
- Kralik, Narayanan, Ramaswamy, et al. Accuracy of CT Imaging for Diagnosis of Acute Invasive Fungal Rhinosinusitis in Children. AJNR Am J Neuroradiol. 2026. PMID: 42618340. doi:10.3174/ajnr.A9600
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。