MRI代谢生物标志物预测超急性卒中缺血灶存活
结果显示约35%的初始DWI核心区出现扩散逆转。联合ADC与rOEF预测梗死AUC达0.80,优于ADC单独预测(AUC 0.65),且在卒中发作120分钟内rOEF附加价值最大。
要点
- 约35%初始ADC核心区在再灌注成功后出现扩散逆转,报告「不可逆梗死」需谨慎。
- 联合ADC与rOEF可提升核心梗死判定准确性,尤其在超急性期(<120分钟)。
核心结论
- 成功再灌注的急性缺血性卒中患者中,在ADC基础上加入rOEF可预测扩散逆转,减少核心梗死体积高估,在超急性时间窗内价值最显著。
关键影像表现/征象
- 约35%初始判定为缺血核心的容积在随访DWI中表现为扩散逆转(存活组织)。
诊断标准与关键数值
- 基线ADC阈值≤620×10⁻⁶ mm²/s用于生成缺血核心掩模;随访DWI用于生成最终梗死掩模。
- 联合ADC+rOEF模型预测梗死的AUC为0.80(95%CI:0.80,0.81),敏感度74%,特异度76%。
- ADC单独预测梗死的AUC为0.65(95%CI:0.64,0.66),敏感度60%,特异度63%,与联合模型比较P<.001。
- 逻辑回归中与缺血核心演变为梗死负相关的独立影像变量为ADC(OR 0.99;95%CI:0.94,1.0;P<.001)和rOEF(OR 0.33;95%CI:0.32,0.35;P<.001)。
临床应用与阅片要点
- 报告超急性期DWI核心区时需警惕扩散逆转可能,结合rOEF有助于识别可能存活组织。
- rOEF的附加价值具有时间依赖性,在卒中发作120分钟内对核心区判定的负向影响最强。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background In patients with acute ischemic stroke (AIS), ischemic core volume overestimation at diffusion-weighted MRI due to diffusion reversal has been described following successful reperfusion. Purpose To assess the potential role of the oxygen extraction fraction (OEF), derived from baseline dynamic susceptibility contrast (DSC) MRI, in diffusion reversal prediction in patients with AIS after successful reperfusion. Materials and Methods This retrospective study (January 2015 to December 2020) included patients with anterior-circulation large-vessel occlusion stroke who underwent pretreatment MRI, including diffusion-weighted imaging and DSC perfusion, achieved successful reperfusion (modified Thrombolysis in Cerebral Infarction score ≥2c), and underwent follow-up MRI within 48 hours. Ischemic core masks were generated from baseline MRI using an apparent diffusion coefficient (ADC) threshold of 620 × 10-6 mm2/sec or less, and infarct masks were generated from the final DWI scans. DSC perfusion was used to calculate the relative OEF (rOEF). Image co-registration and subtraction were performed to determine the final voxel fate as persistent infarct versus surviving tissue. Logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess imaging biomarker predictive value. Results Seventy patients were included (mean age, 72.2 years ± 13.1 [SD]; 40 female). Approximately 35% of the volume initially designated as the ischemic core showed diffusion reversal. Following logistic regression, the independent imaging variables associated with reducing the odds that ischemic core voxels would evolve to infarct voxels were ADC (odds ratio [OR], 0.99; 95% CI: 0.94, 1.0; P < .001) and rOEF (OR, 0.33; 95% CI: 0.32, 0.35; P < .001). A combined ADC plus rOEF model showed an area under the ROC curve (AUC) of 0.80 (95% CI: 0.80, 0.81), sensitivity of 74%, and specificity of 76% for infarct prediction, outperforming ADC alone (AUC, 0.65 [95% CI: 0.64, 0.66], sensitivity, 60%; specificity, 63%; P < .001). The added value of rOEF in delineating ischemic core was time-dependent, with the strongest negative impact within 120 minutes from stroke onset. Conclusion In patients with AIS for whom reperfusion was successful, the addition of rOEF to ADC improved ischemic core definition by predicting diffusion reversal and reducing core volume overestimation, especially in the hyperacute window. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Rapalino in this issue.
引用
- Asghariahmadabad, Ismail, Shams, et al. MRI Metabolic Biomarkers Predict Ischemic Lesion Survival in Hyperacute Stroke: New Insight on Diffusion Reversibility. Radiology. 2026. PMID: 42610810. doi:10.1148/radiol.252121
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。