文献速递外周血管泌尿生殖技术与安全CT

EVAR术后低碘双能CT个性化方案

Personalized low-iodine dual-layer spectral CT protocol for post-endovascular aortic repair imaging: a BMI/eGFR-adapted strategy preserving renal function, quality and diagnostic confidence.
PubMed 文献 · Clin Radiol · 2026-07-24

本研究纳入83例EVAR术后随访患者,采用基于BMI/eGFR分层的低碘双能CT方案。结果显示该方案不引起eGFR显著变化,VNC替代TNC使DLP减少546.2 mGy·cm,40 keV VMI血管强化主客观评分均优于对照组。内漏诊断信心无改变。

要点

  • 低碘双能CT方案在EVAR术后随访中肾功能影响与常规方案相当
  • 40 keV VMI对主动脉、髂动脉及内漏的强化显著优于55 keV及常规图像
  • VNC虽可替代TNC减少辐射,但需警惕假性IIa型内漏的可能

核心结论

  • 低碘双能CT方案在维持肾功能稳定的同时显著减少辐射剂量并改善血管强化质量
  • 40 keV虚拟单能图像在客观与主观血管强化方面均优于55 keV和常规重建

研究设计与样本

  • 单中心回顾性研究,共纳入83例EVAR术后随访患者,平均年龄75±7.3岁
  • 使用双层探测器能谱CT(IQon,Philips),对比剂注射方案按eGFR和BMI分八类剂量-流速组合
  • 客观评价于主动脉、髂动脉、内漏三个标准感兴趣区测量平均衰减、信噪比和对比噪声比

关键影像表现/征象

  • 40 keV虚拟单能图像的血管强化评分优于55 keV及常规图像,金属伪影评分各组无差异
  • VNC替代TNC使DLP减少546.2±176.3 mGy·cm(-34.3±1.4%)

诊断标准与关键数值

  • VMI 40 keV在各感兴趣区的MA、SNR、CNR均最高,其次为VMI 55 keV和常规图像(均P<0.0001)
  • VMI 40 keV血管强化主观评分优于VMI 55 keV(P=0.0014)及常规图像(P<0.0001)
  • 扫描前后eGFR无显著差异(P=0.5617),内漏诊断信心无显著差异(P=0.8150)
  • VNC假阳性IIa型内漏1例,金属伪影主观评分各组无差异(P>0.9999)

临床应用与阅片要点

  • EVAR术后随访CTA应优先重建并阅取40 keV VMI以获取最佳血管与内漏显示
  • VNC可常规用于替代TNC以减少约三分之一辐射剂量,但发现内漏时需与增强图像对照确认
  • 当患者eGFR或BMI变化时需按预设的八类剂量-流速方案调整对比剂注射参数

局限性

  • 单中心回顾性研究设计,结果的外推需要前瞻性多中心验证
  • 仅纳入EVAR术后患者,结论不直接适用于其他主动脉术后随访场景

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To evaluate image quality improvements of a low-iodine contrast medium (CM) protocol optimized with dual-layer spectral CT (DLCT) in patients undergoing post-endovascular aortic repair (EVAR) follow-up.

METHODS: This single-center retrospective study included 83 consecutive patients (mean age: 75 ± 7.3 years) undergoing post-EVAR CTA with a low-iodine protocol optimized for DLCT (IQon, Philips Healthcare). The CM injection protocol, adapted to eGFR and BMI, comprised eight dose-flow categories. Pre-, post-scan eGFR and radiation dose were recorded. Dose-length product (DLP) was compared between true non-contrast (TNC) and virtual non-contrast (VNC) reconstructions. Objective image quality was assessed in standardized ROIs (aorta, iliac arteries, endoleak) by measuring mean attenuation (MA), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) on control CTA (iDose), and virtual monoenergetic images (VMI) at 55 keV and 40 keV. Subjective image quality was rated using a 5-point Likert scale.

RESULTS: No change in eGFR was observed post-CTA (p=0.5617). Substituting TNC with VNC reduced DLP by 546.2 ± 176.3 mGy·cm (-34.3 ± 1.4%, p<0.0001). Across all ROIs, MA, SNR, and CNR were highest with VMI 40 keV, followed by VMI 55 keV and control (all p<0.0001). Vascular enhancement scores were superior with VMI 40 keV versus VMI 55 keV (p=0.0014) and control (p<0.0001), while metal artifact ratings did not differ (p>0.9999). One false-positive type IIa endoleak occurred with VNC, but diagnostic confidence was unchanged (p=0.8150).

CONCLUSIONS: This low-iodine protocol optimized for DLCT significantly reduced radiation dose and improved objective and subjective vascular enhancement without impairing renal function or diagnostic confidence in endoleak detection.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Bédague, Crombé, Pineau, et al. Personalized low-iodine dual-layer spectral CT protocol for post-endovascular aortic repair imaging: a BMI/eGFR-adapted strategy preserving renal function, quality and diagnostic confidence. Clin Radiol. 2026. PMID: 42607567. doi:10.1016/j.crad.2026.107447

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。