文献速递泌尿生殖US

超声影像组学诺模图分级诊断膀胱尿路上皮癌

Application Study of Clinical Features Combined With Ultrasound-based Radiomics Nomogram For Grading Diagnosis of Bladder Urothelial Carcinoma.
PubMed 文献 · Acad Radiol · 2026-08-14

本研究纳入190例膀胱尿路上皮癌患者,均接受二维超声及超声造影检查,提取1240个影像组学特征。结果显示联合二维超声与超声造影的US-C影像组学模型在训练组AUC达0.917,联合临床特征的诺模图训练组AUC达0.939。

要点

  • 联合二维超声与超声造影影像组学模型预测膀胱癌分级效能最高。
  • 临床影像诺模图训练组AUC达0.939,校准曲线拟合优于单一模型。
  • 验证组各模型AUC均低于训练组,提示需外部队列进一步验证。

核心结论

  • 在三种影像组学模型中,联合二维超声与超声造影的US-C影像组学模型对膀胱尿路上皮癌分级预测效能最高。
  • 基于US-C影像组学评分及三个独立预测因素构建的临床影像诺模图校准曲线显示拟合更优。

研究设计与样本

  • 研究类型为回顾性研究,共纳入190例膀胱尿路上皮癌患者。
  • 所有患者均接受二维超声(2D US)和超声造影(CEUS)检查。
  • 以病理结果为参考标准,将患者分为低级别尿路上皮癌组与高级别组。
  • 从每位患者感兴趣区提取1240个影像组学特征,采用逻辑回归建模。

诊断标准与关键数值

  • US影像组学模型训练组AUC为0.772,验证组AUC为0.690。
  • 超声造影(C)影像组学模型训练组AUC为0.868,验证组AUC为0.715。
  • US-C联合影像组学模型训练组AUC为0.917,验证组AUC为0.735。
  • 临床模型训练组AUC为0.766,验证组AUC为0.763。
  • 临床影像诺模图训练组AUC为0.939,验证组AUC为0.807。

临床应用与阅片要点

  • 联合二维超声与超声造影特征可提高膀胱尿路上皮癌分级预测能力,优于单一模态。
  • 诺模图模型在训练组展示出良好的校准度,提示可用于辅助术前分级评估。
  • 验证组AUC下降明显,建议在临床应用中关注过拟合风险。

局限性

  • 验证组各模型AUC均明显低于训练组,存在过拟合可能。
  • 原文未报告外部验证、多中心设计及建模变量选择细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

UNLABELLED: RATIONALE AND OBJECTIVE: This study aims to develop a prediction model using multimodal ultrasound (US) images and clinical features to evaluate its effectiveness in predicting bladder cancer grading.

MATERIALS AND METHODS: We selected 190 patients with bladder urothelial carcinoma; each patient underwent 2D US and contrast-enhanced US examinations. Based on pathological results, the patients were categorized into either a low-grade urothelial carcinoma group or a high-grade group. We extracted 1240 radiomic features from each patient's region of interest. Using logistic regression, we established the US radiomics model, the contrast (C) radiomics model, and the US-C radiomics model. Diagnostic accuracy was evaluated using receiver operating characteristic curve analysis. Based on the rad score obtained from the US-C radiomics model and three independent predictive factors, we constructed a clinical imaging nomogram.

RESULTS: The area under the curve (AUC) values for the US radiomics model, the C radiomics model, and the US-C radiomics model were 0.772, 0.868, and 0.917, respectively, in the training groups. In the validation groups, the AUC values were 0.690, 0.715, and 0.735, respectively. The predictive power of the clinical model was 0.766 in the training group and 0.763 in the validation group. The predictive performance of the clinical imaging nomogram was 0.939 in the training group and 0.807 in the validation group.

CONCLUSION: Among the three models, the US-C radiomics model demonstrated the highest predictive performance. The calibration curve indicates that the nomogram model provides a superior fit for predicting the grading of bladder urothelial carcinoma.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Fu, Fan, et al. Application Study of Clinical Features Combined With Ultrasound-based Radiomics Nomogram For Grading Diagnosis of Bladder Urothelial Carcinoma. Acad Radiol. 2026. PMID: 42601302. doi:10.1016/j.acra.2026.07.059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。