文献速递腹部技术与安全CT

低浓度碘对比剂腹部门静脉期光子计数CT虚拟单能成像可行性

Feasibility of low concentration iodinated contrast medium in portal venous abdominal imaging: performance of photon-counting CT virtual monoenergetic imaging compared to conventional EID-CT.
PubMed 文献 · Eur J Radiol · 2026-08-05

本回顾性研究纳入84例腹部PCCT低碘对比剂(270 mg I/mL)检查患者,与其一年内常规EID-CT(350 mg I/mL)对照。结果显示PCCT总碘量及辐射剂量更低,45-50 keV VMI在图像质量上不劣于常规EID-CT,可用于门静脉期成像。

要点

  • 低碘PCCT门静脉期成像推荐使用45-50 keV虚拟单能图像,对比噪声比与图像质量较稳定。
  • 40 keV虽然提高胰腺、门静脉、脾脏CNR,但主观图像质量评分较低,阅片需谨慎。
  • 肝脏在PCCT低碘方案中SNR下降明显,评估肝实质病变时应注意噪声影响。

核心结论

  • 低碘PCCT在门静脉期腹部成像中可实现与标准碘EID-CT相当或更优的定量图像质量,且辐射与碘剂量更低。
  • 45-50 keV为门静脉期低碘PCCT最佳虚拟单能成像区间,可兼顾对比度与噪声。
  • 该方案在日常门静脉期腹部扫描中具有潜在临床可行性。

研究设计与样本

  • 回顾性研究,纳入84例接受腹部盆腔PCCT检查的成人患者。
  • 研究对象均有近一年内采用常规对比剂350 mg I/mL的EID-CT检查资料。
  • 通过虚拟单能成像40-65 keV计算器官特异性对比噪声比与信噪比。
  • 两名放射科医生独立采用5分Likert量表评估40、45、50 keV主观图像质量。
  • 非劣效性检验采用预设-0.5分界值。

关键影像表现/征象

  • 40 keV时RI-PCCT的胰腺、门静脉、脾脏对比噪声比显著高于SI-EIDCT。
  • 肝脏对比噪声比在40 keV时与SI-EIDCT相近。
  • 肝脏信噪比在低碘PCCT中出现明显下降。

诊断标准与关键数值

  • PCCT组总碘剂量为400.60 ± 29.82 mgI/kg,EID-CT组为517.88 ± 39.46 mgI/kg,差异有统计学意义(P < 0.001)。
  • 40 keV时胰腺、门静脉、脾脏CNR均显著高于SI-EIDCT(均P < 0.001)。
  • 45 keV与50 keV所有主观图像质量参数均达到预设-0.5分非劣效性标准。
  • 40 keV主观图像质量评分低于其他能级水平。
  • 观察者间一致性极佳(Gwet's AC2为0.932-0.975)。

临床应用与阅片要点

  • 报告低碘PCCT门静脉期图像时可优先选用45-50 keV虚拟单能图像进行判读。
  • 评估肝实质时应考虑到低碘PCCT肝脏信噪比下降可能影响小病灶检出。
  • 40 keV虽提高部分脏器对比度,但噪声增加导致主观评分下降,不宜作为默认重建能级。

局限性

  • 本研究为回顾性设计。
  • PCCT与EID-CT为两次不同时间检查,可能存在采集参数与患者状态差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate whether reduced-iodine photon-counting CT (RI-PCCT) virtual monoenergetic imaging (VMI) provides comparable quantitative and non-inferior qualitative image quality compared with standard-iodine energy-integrating detector CT (SI-EIDCT) in portal venous phase abdominal imaging, and to identify the optimal keV range.

MATERIALS AND METHODS: This retrospective study included 84 adult patients who underwent abdominopelvic PCCT using a lower-concentration iodinated contrast medium (270 mg I/mL) administered at the same injection volume as routine practice, resulting in a reduced total iodine dose, and who had a prior conventional EID-CT performed with standard contrast medium (350 mg I/mL) within one year. Organ-specific contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated across virtual monoenergetic imaging (VMI) levels ranging from 40 to 65 keV and compared with EID-CT. Two independent radiologists assessed subjective image quality at predefined VMI levels (40, 45, and 50 keV) using a 5-point Likert scale. Non-inferiority testing was performed using a predefined margin of -0.5.

RESULTS: The total iodine dose was significantly lower in the PCCT group than in the EID-CT group (400.60 ± 29.82 vs. 517.88 ± 39.46 mgI/kg, P < 0.001). At 40 keV, RI-PCCT demonstrated higher CNR than SI-EIDCT for the pancreas, portal vein, and spleen (all P < 0.001), whereas liver CNR was similar. SNR showed organ-specific reductions, particularly in the liver. Qualitative scores were lower at 40 keV, but 45 keV and 50 keV met the predefined non-inferiority criterion for all qualitative parameters using a -0.5-point margin. Interobserver agreement was excellent for all qualitative parameters (Gwet's AC2, 0.932-0.975).

CONCLUSIONS: RI-PCCT provided comparable quantitative and non-inferior qualitative image quality compared with SI-EIDCT, while lowering the iodine and radiation dose. VMI at 45-50 keV provided the optimal balance of contrast and noise, supporting its potential clinical feasibility for routine portal venous phase imaging.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim, Byun. Feasibility of low concentration iodinated contrast medium in portal venous abdominal imaging: performance of photon-counting CT virtual monoenergetic imaging compared to conventional EID-CT. Eur J Radiol. 2026. PMID: 42594607. doi:10.1016/j.ejrad.2026.113144

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。