多期CT在术前定位甲状旁腺腺瘤中的诊断价值
结果显示多期CT定位敏感度为70.4%、特异度为86.4%,定侧敏感度为82.6%、特异度为86.2%。多期CT作为二线影像具备可靠诊断准确性与中等阳性似然比,有助于微创手术决策。
要点
- 一线MIBI SPECT/CT与超声阴性或不一致时,多期CT可作为二线术前定位手段。
- 多期CT定位特异度高,阳性结果对选择微创手术有较高把握。
- 多期CT定侧效能优于象限定位,可优先用于判断病灶侧别。
核心结论
- 多期CT对一线影像阴性或不一致的甲状旁腺腺瘤具有可靠的定位与定侧诊断准确性。
- 多期CT定位特异度为86.4%,定侧特异度为86.2%,阳性似然比分别为5.26和5.99。
- 高特异度与中等阳性似然比使其成为适合微创手术决策的「rule-in」工具。
诊断标准与关键数值
- 多期CT对术前腺瘤象限定位的敏感度为70.4%(95%CI:58-81),特异度为86.4%(95%CI:79-92)。
- 多期CT对术前腺瘤定侧的敏感度为82.6%(95%CI:72-91),特异度为86.2%(95%CI:68-96)。
- 多期CT定位阳性似然比为5.26,定侧阳性似然比为5.99。
临床应用与阅片要点
- 当MIBI SPECT/CT与超声结果阴性或相互不一致时,可加做多期CT辅助术前定位。
- 多期CT阳性结果可作为微创甲状旁腺手术术前定位与定侧依据。
- 解读时可优先评价侧别,因定侧敏感度和特异度均高于象限定位。
局限性
- 研究为回顾性设计,样本来自单中心5年数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To quantify the diagnostic utility of multiphase CT as a second-line imaging modality for parathyroid adenoma localization including assessing the differences between patients undergoing second-line imaging due to negative or discordant first-line imaging (MIBI SPECT/CT) results.
METHODS: Patients undergoing multiphase CT following negative or discordant first-line imaging were collected retrospectively over a 5-year period from 2019 to 2023. Seventy-three patients were included. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, positive and negative likelihood ratios of multiphase CT for preoperative parathyroid adenoma lateralization (correct side) and localization (correct quadrant) were calculated. Results for the whole cohort, negative imaging cohort, and discordant imaging cohorts were compared.
RESULTS: Fifty-eight of the included patients were female, and 15 were male. Mean age was 56.2 ± 11.8. One-hundred eighty-three quadrants and 98 sides were explored surgically. Thirty-seven patients (69.8%) underwent a minimally invasive surgical procedure. Across the whole cohort, multiphase CT demonstrated a sensitivity of 70.4% (95% CI: 58-81) and specificity of 86.4% (79-92). For lateralization, performance was higher with sensitivity 82.6% (72-91) and specificity 86.2% (68-96). Moderate positive likelihood ratios were also recorded as 5.26 (localization) and 5.99 (lateralization).
CONCLUSIONS: Multiphase CT provided reliable diagnostic accuracy for localization and lateralization of parathyroid adenomas in the context of discordant or negative first-line imaging. Its high specificity and moderate positive likelihood ratios make it a valuable rule-in tool that enables targeted surgical approaches.
ADVANCES IN KNOWLEDGE: This study provides one of the largest datasets in the literature. Positive results suggest that CT can be considered in cases of negative or discordant first-line imaging if minimally invasive surgical techniques are desired.
引用
- Cowen, Fung, Ward, et al. The diagnostic utility of multiphase CT (4D CT) in localizing parathyroid adenomas following negative or discordant 99mTc-sestamibi SPECT/CT and ultrasound imaging. Br J Radiol. 2026. PMID: 42584085. doi:10.1093/bjr/tqag184
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。