指南与共识妇产影像US

经阴道超声直接与间接征象诊断子宫腺肌症的诊断准确性

Diagnostic accuracy of transvaginal ultrasound for adenomyosis using consensus-based direct and indirect sonographic signs: prospective cohort study.
指南 / 共识 · Ultrasound Obstet Gynecol · 2026-08-12

本研究为前瞻性队列研究,纳入2967例接受经阴道超声检查的女性,其中345例在检查后6周内行子宫切除术并纳入最终分析。以组织病理学为参考标准,评估MUSA共识中直接与间接超声征象对子宫腺肌症的诊断效能。结果显示单个直接征象特异度高但敏感度有限,间接征象特异度超过97%但敏感度低;直接征象联合模型特异度为93.7%,敏感度为60.0%,加入间接征象未带来额外获益。

要点

  • 直接征象中子宫内膜下强回声线的特异性与敏感度平衡最好,应优先识别并报告。
  • 间接征象特异度高但敏感度低,宜作为支持性证据而非独立诊断依据。
  • 联合直接征象可提高诊断特异度,但敏感度仍有限,阴性时不能完全排除腺肌症。

核心结论

  • 经阴道超声诊断子宫腺肌症时,直接征象具有最一致的诊断价值,间接征象应作为支持性而非确定性证据。
  • 联合直接超声征象可达到高特异度(93.7%)但敏感度有限(60.0%)。
  • 加入间接超声征象未对诊断模型产生有意义的增量效益。

研究设计与样本

  • 纳入年龄≥18岁、经阴道超声检查后6周内接受子宫切除术的女性,排除组织病理学为恶性的病例。
  • 超声征象依据修订版MUSA共识评估,以组织病理学结果为参考标准。
  • 共2967例接受经阴道超声评估,其中345例(11.6%)在检查后6周内行子宫切除术并构成研究队列。

关键影像表现/征象

  • 直接征象中,子宫内膜下强回声线的敏感度为53.5%(95% CI,45.4-61.6%),特异度为94.7%(95% CI,90.5-97.4%),总体平衡最佳。
  • 单个间接征象特异度超过97%,但敏感度低。
  • 联合直接超声征象的模型总体诊断准确性为78.6%(95% CI,73.8-82.8%)。

诊断标准与关键数值

  • 直接征象联合模型:敏感度60.0%(95% CI,51.8-67.8%),特异度93.7%(95% CI,89.2-96.7%)。
  • 子宫内膜下强回声线:敏感度53.5%(95% CI,45.4-61.6%),特异度94.7%(95% CI,90.5-97.4%)。
  • 单个间接征象特异度>97%,敏感度低。

临床应用与阅片要点

  • 超声报告应区分直接征象与间接征象,避免将间接征象作为独立诊断依据。
  • 发现子宫内膜下强回声线等直接征象时,应明确提示子宫腺肌症可能。
  • 即使直接征象联合模型为阴性,仍不能完全排除腺肌症,需结合临床综合判断。

局限性

  • 研究仅纳入接受子宫切除术的患者,存在选择偏倚,结果可能不适用于未手术人群。
  • 研究为单中心设计,结果的外推性受限。
  • 队列中仅11.6%接受子宫切除术,可能遗漏较轻或不需手术的腺肌症病例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance of transvaginal ultrasound (TVS) for adenomyosis using consensus-based direct and indirect ultrasound signs, with histopathology as the reference standard.

METHODS: This prospective diagnostic accuracy study included women undergoing TVS examination at a tertiary referral center (Hospital San Juan de Dios, Santiago, Chile) between 1 December 2022 and 1 December 2023. Women aged ≥ 18 years who underwent hysterectomy within 6 months after TVS examination were enrolled consecutively. Cases with malignant histopathological findings were excluded. Ultrasound signs of adenomyosis were assessed according to the revised Morphological Uterus Sonographic Assessment consensus. Histopathology served as the reference standard. Diagnostic performance measures for individual ultrasound features and multivariable models were calculated.

RESULTS: Among 2967 women evaluated using TVS, 345 (11.6%) underwent hysterectomy within 6 weeks and constituted the study cohort. Histopathology confirmed adenomyosis in 155 (44.9%) women. Individual ultrasound features showed high specificity but limited sensitivity. Among direct signs, echogenic subendometrial lines showed the best overall balance (sensitivity, 53.5% (95% CI, 45.4-61.6%); specificity, 94.7% (95% CI, 90.5-97.4%)). Individual indirect signs showed specificity > 97% but low sensitivity. A model combining direct ultrasound signs showed high specificity (93.7% (95% CI, 89.2-96.7%)) but limited sensitivity (60.0% (95% CI, 51.8-67.8%)); overall diagnostic accuracy was 78.6% (95% CI, 73.8-82.8%). The addition of indirect ultrasound signs into the model did not provide meaningful incremental benefit.

CONCLUSIONS: Our findings highlight the importance of distinguishing between direct and indirect ultrasound features, with direct signs providing the most consistent diagnostic value, while indirect signs should be interpreted as supportive rather than definitive. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Morales, Crovo, Ebner, et al. Diagnostic accuracy of transvaginal ultrasound for adenomyosis using consensus-based direct and indirect sonographic signs: prospective cohort study. Ultrasound Obstet Gynecol. 2026. PMID: 42584944. doi:10.1002/uog.70315

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。