机器人辅助与手动神经血管内介入比较的系统综述与荟萃分析
该系统综述纳入6项比较机器人辅助与手动神经血管内介入的研究,3项使用CorPath GRX系统。结果显示机器人辅助手术室总时间显著延长(MD 12.42 min;95% CI 6.31至18.53),但对比剂用量显著降低(MD -6.20 ml;95% CI -11.91至-0.50)。手术时间、透视时间、患者辐射暴露、诊断及操作成功率、入路转换、TIA或卒中事件及总并发症率无显著差异。
要点
- 机器人辅助神经介入增加手术室总时间但减少对比剂用量
- 诊断和操作成功率与手动操作无显著差异
- TIA或卒中事件及总并发症率与手动操作无显著差异
核心结论
- 机器人辅助较手动神经血管内介入手术室总时间显著延长,但对比剂用量显著降低
- 诊断成功率、操作成功率、入路转换、TIA或卒中事件及总并发症率无显著差异
研究设计与样本
- 系统综述与随机效应模型配对荟萃分析,检索PubMed、Embase、Web of Science、Scopus自建库至2026年2月
- 纳入6项比较机器人辅助与手动神经血管内介入的研究,其中3项使用CorPath GRX系统
诊断标准与关键数值
- 手术室总时间:机器人辅助组显著延长(MD 12.42 min;95% CI 6.31至18.53)
- 对比剂用量:机器人辅助组显著降低(MD -6.20 ml;95% CI -11.91至-0.50)
- 手术时间和透视时间:机器人辅助与手动组无显著差异
- 患者辐射暴露、DCA诊断成功率、操作成功率、入路转换、TIA或卒中事件及总并发症率均无显著差异
临床应用与阅片要点
- 机器人辅助神经介入可减少对比剂用量,对肾功能受损患者可能有益
- 机器人辅助会增加手术室占用时间,科室排班时需加以考虑
- 机器人辅助未增加TIA或卒中等并发症,可作为部分神经介入操作的替代方式
局限性
- 所纳入研究涉及的术式范围较窄
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Robot-assisted (RA) procedures are emerging in the field of neuroradiology, and robots are being used in various neuroendovascular procedures, including carotid artery stenting, cerebral angiography, and mechanical thrombectomy.
PURPOSE: This study aims to synthesize up-to-date knowledge on this subject and to compare RA with manual neuroendovascular procedures.
DATA SOURCES: PubMed, Embase, Web of Science, and Scopus libraries were searched from inception to February 2026.
STUDY SELECTION: Studies comparing RA and manual neuroendovascular interventions were included.
DATA ANALYSIS: Synthesis of evidence was performed through pairwise meta-analysis utilizing a random-effects model.
DATA SYNTHESIS: After a comprehensive search, this study included 6 papers. Three studies used the CorPath GRX system for the procedures. RA procedures showed significantly longer operating room time (MD 12.42 min; 95% CI 6.31 to 18.53). However, procedure and fluoroscopy times did not differ significantly. The RA group showed significantly lower contrast volume (MD -6.20 ml; 95% CI -11.91 to -0.50). Patient radiation exposure, DCA diagnostic success, procedural success, procedural access point conversion, incidence of TIA or stroke events, or overall complication rate showed no significant differences.
LIMITATIONS: Currently, the review is limited by the narrow range of procedures studied.
CONCLUSIONS: Exploratory results from this review suggested longer overall operating room time with robots but lower contrast volume than with conventional neuroendovascular procedures.
引用
- Łajczak, Łajczak, Ahmed, et al. Robot-assisted versus manual neuroendovascular interventions - updated systematic review and pairwise meta-analysis. AJNR Am J Neuroradiol. 2026. PMID: 42580865. doi:10.3174/ajnr.A9580
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。