卵巢肿块超声风险分层:O-RADS v2022与深度学习比较
本研究回顾性分析227例患者512张超声图像,比较放射科医师应用O-RADS v2022与16种深度学习模型的诊断效能。结果显示ViT16-384性能最佳,AUC达0.941。放射科医师O-RADS评分与AI预测概率融合后,多数模型效能显著提升。
要点
- 放射科医师单独应用O-RADS v2022的AUC仅为0.683,深度学习模型ViT16-384可达0.941
- 放射科医师O-RADS评分与AI预测概率融合后,12个CNN中9个、4个ViT中3个效能显著提升
- 人机融合模式有助于标准化超声判读、减少假阳性并提高高危卵巢肿块识别
核心结论
- 深度学习模型在卵巢肿块超声风险分层中优于放射科医师单独应用O-RADS v2022
- 放射科医师O-RADS评分与AI预测概率的融合框架可获得最高诊断效能
研究设计与样本
- 回顾性研究,共纳入227例患者的512张超声图像,其中110例至少有1个恶性病灶
- 训练并验证16种深度学习模型,包括DenseNets、EfficientNets、ResNets、VGGs、Xception及ViTs
- 为每个模型构建融合放射科医师O-RADS评分与深度学习预测恶性概率的混合框架
诊断标准与关键数值
- 放射科医师单独O-RADS评估的AUC为0.683,准确率为68.0%
- CNN模型AUC范围为0.620-0.908,准确率范围为59.2%-86.4%
- ViT16-384达到最佳性能,AUC为0.941,准确率为87.4%
临床应用与阅片要点
- 临床可考虑将放射科医师O-RADS评分与深度学习预测概率结合,辅助卵巢肿块超声风险分层
- 深度学习模型可作为标准化超声判读的辅助工具,有助减少假阳性诊断
- 融合模式下提高高危卵巢病变识别,可能改善后续临床处置决策
局限性
- 本研究为回顾性设计,存在固有偏倚
- 样本仅为227例患者共512张超声图像,规模有限
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The 2022 update of the Ovarian-Adnexal Reporting and Data System (O-RADS) improves risk stratification of adnexal lesions; however, radiologist interpretation remains subject to inter-observer variability and conservative diagnostic thresholds. Concurrently, deep learning (DL) models demonstrated promise in ovarian mass characterization. This study evaluates radiologist performance applying O-RADS version 2022 (v2022), compares it to convolutional neural network (CNN) and vision transformer (ViT) models, and investigates diagnostic gains from hybrid human-artificial intelligence (AI) frameworks with emphasis on explainable DL approaches that could enhance clinical applicability.
METHODS: In this retrospective study, a total of 512 ultrasound images from 227 patients (110 with at least 1 malignant lesion) were analyzed. Sixteen DL models, including DenseNets, EfficientNets, ResNets, VGGs, Xception, and ViTs were trained and validated. For each model, a hybrid framework integrating radiologist-assigned O-RADS scores with DL-predicted malignancy probabilities was constructed.
RESULTS: Radiologist-only O-RADS assessment achieved an area under the curve (AUC) of 0.683 and an accuracy of 68.0%. CNN models yielded AUCs of 0.620-0.908 and accuracies of 59.2-86.4%, while ViT16-384 reached the best performance, with an AUC of 0.941 and an accuracy of 87.4%. Hybrid human-AI frameworks significantly enhanced most CNNs (9 out of 12 CNNs, p < .05) and ViTs (3 out of 4 ViTs, p < .05).
CONCLUSIONS: DL models outperform radiologist-only O-RADS v2022 assessment. The integration of expert radiologist scores with AI yields the highest accuracy, supporting hybrid human-AI paradigms as a promising approach to standardize ultrasound interpretation, reduce false-positive diagnoses, and improve identification of high-risk ovarian lesions.
引用
- Ardakani, Mohammadi, Mohebbi, et al. From ACR O-RADS 2022 to Explainable Deep Learning: Comparative Performance of Expert Radiologists, Convolutional Neural Networks, Vision Transformers, and Fusion Models for Ultrasound-Based Risk Stratification of Ovarian Masses. J Ultrasound Med. 2026. PMID: 42572015. doi:10.1002/jum.70401
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。