ACR适用性标准:惰性肺癌影像监测
针对临床团队决定暂缓干预的惰性肺癌患者,ACR多学科专家小组制定影像监测适用性指南。指南强调监测目标是发现可能改变治疗决策的显著变化,影像手段选择应依据其准确性及对治疗决策的影响。诊断性检查与活检不应视为监测的一部分。
要点
- 持续性或缓慢生长的亚实性结节与非典型肺囊肿常提示惰性肺癌。
- 暂缓干预时影像监测的核心目的是发现足以改变处理策略的显著变化。
- 一旦决定治疗,应进行诊断性影像学检查和活检,不应纳入监测范畴。
核心结论
- 对暂缓干预的惰性肺结节患者,影像监测应聚焦于识别可能改变治疗决策的显著变化。
- 影像手段的选择取决于其准确性以及结果是否会影响治疗决策。
研究设计与样本
- 制定机构为美国放射学会(ACR),由多学科专家小组每年审查。
- 指南基于同行评议期刊医学文献的系统分析,方法学采用GRADE框架。
- 适用性判定依据RAND/UCLA适用性方法用户手册确定。
关键影像表现/征象
- 持续性或缓慢生长的亚实性结节是非惰性肺癌的重要提示征象。
- 非典型肺囊肿可能代表惰性形式的肺癌。
临床应用与阅片要点
- 惰性肺结节患者应由多学科肿瘤委员会评估风险、自然病程、治疗选择及患者意愿。
- 对选择影像监测的患者,阅片时需重点关注结节大小、密度或形态的显著变化。
- 缺乏或无法确定同行评议文献时,专家意见可作为推荐形成的主要证据来源。
局限性
- 在部分临床场景中缺乏同行评议文献或证据不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Persistent or slow-growing subsolid nodules and atypical lung cysts often represent indolent forms of lung cancer. These nodules require careful assessment by a multidisciplinary tumor board to determine risk, natural history, treatment options, and patient preferences. When the preferred management is imaging surveillance rather than active intervention, the main objective is to detect significant changes that could alter patient management. The choice of imaging modality should be based on its accuracy and whether the findings will influence the decision to pursue treatment. If the team determines that treatment is necessary, a diagnostic imaging workup and a biopsy are typically indicated and should not be considered part of surveillance. Therefore, this document aims to outline evidence-based guidelines specifically for imaging surveillance of indolent pulmonary nodules in patients for whom the clinical team has chosen to delay intervention. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
引用
- Digumarthy, Messick, Walker, et al. ACR Appropriateness Criteria® Indolent Lung Cancer. J Am Coll Radiol. 2026. PMID: 42573542. doi:10.1016/j.jacr.2026.07.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。