文献速递儿科影像神经MR

胎儿MRI低位脊髓圆锥的产后关联分析

Low Conus Position on Fetal MRI with Postnatal Correlation.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-08-18

本研究回顾性纳入2011至2022年间胎儿MRI报告低位脊髓圆锥且无其他脊柱裂的病例,共有203次检查、224例胎儿,部分病例经产后影像与临床随访确认。比较以腰椎椎体水平和肾脏下缘为标志的两种定位方法,发现两者预测产后低位圆锥的准确率无统计学差异。第三孕期联合使用两种标志可能提高诊断可信度。

要点

  • 胎儿MRI孤立性低位圆锥中,约65%产后影像确认仍为低位(L3或以下)
  • 以椎体水平或肾脏下缘定位圆锥,预测产后低位的准确率无显著差异
  • 第三孕期联合两种标志可能提高孤立性低位圆锥的诊断信心

核心结论

  • 以腰椎椎体水平和肾脏下缘为标志,两种胎儿MRI方法均可预测多数产后低位圆锥,准确率差异无统计学意义(P=0.66)
  • 第三孕期联合使用两种标志可能提高孤立性低位圆锥的诊断信心

研究设计与样本

  • 回顾性队列研究,纳入2011至2022年间胎儿MRI检查,共203次检查、224例胎儿
  • 纳入标准为胎儿MRI报告孤立性低位圆锥且无其他脊柱裂,并有产后随访资料
  • 每例以腰椎椎体水平定位和肾脏下缘定位两种方法重新分类为正常或低位
  • 收集产后影像学和临床随访数据,包括手术松解情况

关键影像表现/征象

  • 34例有产后脊柱影像学随访,其中22例(65%)确认低位圆锥,定义为L3或以下水平
  • 22例产后确认低位圆锥者中9例(41%)接受脊髓栓系松解手术

诊断标准与关键数值

  • 产后低位圆锥诊断标准为圆锥位于L3椎体水平或以下
  • 两种圆锥定位方法预测产后低位圆锥的准确率无统计学显著差异(P=0.66)

临床应用与阅片要点

  • 胎儿MRI报告孤立性低位圆锥时,可分别或联合使用腰椎椎体水平和肾脏下缘作为定位标志
  • 解读胎儿MRI孤立性低位圆锥需考虑胎龄、腰骶移行椎解剖、尾侧退化2型及隐匿性栓系病变的影响
  • 第三孕期联合定位可能减少假阳性判断

局限性

  • 回顾性队列研究设计
  • 仅34/224例(15%)有产后脊柱影像学随访

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Abnormal low position of the conus medullaris on fetal MRI may portend tethered cord syndrome after birth. However, prenatal identification of low conus is challenging and frequently requires postnatal confirmation. This study aimed to compare two methods for evaluating conus position on fetal MRI by correlating with postnatal outcomes.

MATERIALS AND METHODS: This is a retrospective cohort study of fetal MRIs performed between 2011-2022 that reported low conus in the absence of other spinal dysraphism and had available postnatal follow-up. Each case was re-classified as normal or low conus, using two methods: localization relative to lumbar vertebral level versus the inferior border of the kidneys. Postnatal imaging and clinical follow-up data including surgical detethering were also collected.

RESULTS: We found 203 fetal MRI examinations (224 fetuses in total) that reported low conus, 15% (34/224) with available postnatal spinal imaging, 65% (22/34) with confirmed low conus (level L3 or below), and 41% (9/22) who were treated with detethering surgery. There was no statistically significant difference between the accuracies of the two approaches (p = 0.66) in predicting low conus on postnatal imaging.

CONCLUSIONS: Both the vertebral level and the inferior renal border landmarks on fetal MRI can be used to predict postnatal low conus in the majority of cases, without a statistically significant difference between the two methods. A combined approach performed in the third trimester may improve diagnostic confidence. Interpretation of isolated low conus on fetal MRI may be influenced by factors including gestational age, transitional lumbosacral anatomy, caudal regression group 2, and occult tethering lesions.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Kong, Bierbrauer, Choi, et al. Low Conus Position on Fetal MRI with Postnatal Correlation. AJNR Am J Neuroradiol. 2026. PMID: 42551956. doi:10.3174/ajnr.A9562

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。