宽体探测器CT全心运动校正用于无ECG导联CCTA
结果显示全心运动校正联合深度学习重建显著降低噪声、提高SNR/CNR,图像质量评分最高,患者水平可判读率达100%。
要点
- 无ECG导联CCTA中,全心运动校正可显著提升图像质量,推荐用于替代标准重建。
- 全心运动校正对远端血管和小分支的显示优势明显,报告时应优先采用该重建序列阅片。
- 患者水平可判读率达100%,提示无ECG导联方案结合全心运动校正具备临床应用价值。
核心结论
- 全心运动校正算法在无ECG导联CCTA中显著提升图像质量与冠脉可判读性,远端血管及小分支显示更具优势。
研究设计与样本
- 每例图像分别采用标准重建、血管追踪运动校正和全心运动校正三种算法重建,三组均叠加深度学习图像重建算法。
- 客观评价指标包括噪声、信噪比和对比噪声比;主观图像质量由两名放射科医师采用5分Likert量表评分。
- 冠脉可判读性按节段、血管和患者三个水平分别评估。
关键影像表现/征象
- 全心运动校正重建在主观图像质量评分上最高,中位数5.0分,优于血管追踪运动校正的4.0分和标准重建的3.0分。
- 全心运动校正对近段和中段冠脉的可判读性达99.6%,对远端血管和小分支的可判读性达97.2%。
诊断标准与关键数值
- 两名放射科医师主观评分的一致性κ=0.87。
- 患者水平可判读性:全心运动校正达100%,血管追踪运动校正为92.9%,标准重建为51.4%。
临床应用与阅片要点
- 无ECG导联CCTA条件下,应采用全心运动校正重建作为常规阅片序列,以弥补心电图信号缺失对图像质量的影响。
- 评估远端冠脉及小分支病变时,优先参考全心运动校正重建图像,避免漏诊。
- 全心运动校正联合深度学习图像重建在降低噪声的同时保持可读性,适合急性胸痛快速扫描流程。
局限性
- 仅纳入了窦性心律患者,结果对心律失常或高心率患者的外推性尚不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study evaluates the impact of a whole heart motion correction algorithm on image quality and interpretability in coronary computed tomography angiography (CCTA) without ECG leads.
MATERIALS AND METHODS: Seventy patients with acute chest pain underwent CCTA without ECG leads examination. Images were reconstructed with standard (STD), coronary vessel tracking motion correction (Snapshot Freeze 1, SSF1), and whole‑heart motion correction (Snapshot Freeze 2, SSF2) algorithms. Additionally, all three groups underwent deep learning image reconstruction (DLIR) algorithm. Objective evaluation, including noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. Subjective image quality was scored by two radiologists using a 5 - point Likert scale. Interpretability of coronary vessels was assessed per segment, vessel, and patient.
RESULTS: SSF2 significantly reduced noise and improved SNR/CNR compared to STD and SSF1 (all P < .05). Subjective scores were highest for SSF2 (median 5.0 vs 4.0 for SSF1 and 3.0 for STD, P < .001), with inter-observer agreement (κ = 0.87). SSF2 achieved higher interpretability for proximal/mid-segments (99.6%) and improved distal/small-branch interpretability (97.2% vs 89.4% for SSF1, P < .017). Patient-level interpretability reached 100% with SSF2, vs 92.9% (SSF1) and 51.4% (STD).
CONCLUSION: SSF2 enhances image quality and interpretability in CCTA without ECG leads, and exhibits favorable in the visualization of distal vessels and small branches.
引用
- Zhao, Wang, Dong, et al. CCTA without ECG Leads Using Whole-Heart Motion Correction Algorithm Based on Wide-Detector CT. Acad Radiol. 2026. PMID: 42552154. doi:10.1016/j.acra.2026.06.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。