基于胸片深度神经网络骨龄评估的概念验证研究
本研究回顾性纳入101例3–15岁儿童共237张胸片,以手部TW2-RUS骨龄为参考标准,微调三种深度神经网络评估骨龄。结果显示性别考虑模型一致性更高,ICC达0.87,RMSE为1.30岁。提示胸片有机会性评估骨龄的可行性。
要点
- 性别考虑模型性能优于不考虑性别的模型,阅片时可关注性别分层算法差异。
- 胸片骨龄评估ICC最高0.87,提示可作手片不可用时的机会性替代。
- 本研究排除骨骼发育不良及胸壁畸形患儿,常规阅片需警惕此类病例。
核心结论
- 胸片深度神经网络评估骨龄可行,性别考虑模型与参考标准一致性更高。
- 该技术在手部专用骨龄片不可及时具有机会性应用的潜在价值。
研究设计与样本
- 回顾性研究,纳入三级医疗中心20年间同时接受胸片和手片检查的3–15岁儿童。
- 180例筛查后纳入101例,共237张胸片;排除骨骼发育不良或胸壁异常者。
- 参考标准为儿科内分泌医师采用TW2-RUS法判读手片,微调三种预训练深度神经网络。
关键影像表现/征象
- 胸片骨龄估计与手部TW2-RUS参考标准一致性良好。
- 性别考虑模型ICC上限0.87,对应RMSE低至1.30岁。
诊断标准与关键数值
- 性别不考虑模型ICC最高0.81(95%CI 0.48–0.97),RMSE 1.52岁(95%CI 0.67–2.20)。
- 性别考虑模型ICC最高0.87(95%CI 0.63–0.99),RMSE 1.30岁(95%CI 0.56–1.95)。
临床应用与阅片要点
- 胸片报告可提示AI骨龄估计作为附加信息,但需注明基于胸片而非标准手片。
- 临床应用时优先选用性别考虑模型,其误差低于性别不考虑模型。
局限性
- 单中心回顾性研究,样本量仅101例,外部普适性有限。
- 本研究为概念验证,胸片骨龄模型尚未在独立外部数据集验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Bone age (BA) is the gold standard for skeletal maturity assessment but is not routinely incorporated into pediatric growth evaluation workflow because it requires dedicated hand radiographs and specialist interpretation.
OBJECTIVE: To develop an estimation model for BA from chest radiographs using deep neural networks.
MATERIALS AND METHODS: We retrospectively analyzed children aged 3-15 years who underwent both chest and hand radiography at a tertiary center over 20 years. Patients with skeletal dysplasia or chest wall abnormalities were excluded. Reference BA was determined from hand radiographs by pediatric endocrinologists using the Tanner-Whitehouse 2 radius-ulna-short bones (TW2-RUS) method. Three pretrained deep neural networks were fine-tuned to estimate BA from chest radiographs using sex-non-considering models and sex-considering models. Model performance was evaluated using the intraclass correlation coefficient (ICC), root mean squared error (RMSE), and related metrics.
RESULTS: Of 180 screened patients, 101 were included, yielding 237 chest radiographs. Estimated BA showed good concordance with the reference standard, with ICCs up to 0.81 (95% CI 0.48-0.97) for sex-non-considering models and 0.87 (95% CI 0.63-0.99) for sex-considering models. Corresponding RMSEs were 1.52 (95% CI 0.67-2.20) and 1.30 (95% CI 0.56-1.95), respectively.
CONCLUSION: This proof-of-concept study demonstrates the feasibility of estimating BA from pediatric chest radiographs using deep neural networks. These findings suggest potential opportunistic use when dedicated hand radiographs are unavailable.
引用
- Ota, Hanawa, Yoshihara, et al. Bone age estimation from chest radiographs using deep neural networks: a proof-of-concept study. Pediatr Radiol. 2026. PMID: 42570094. doi:10.1007/s00247-026-06746-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。