文献速递骨肌PETMRCT

冻结肩炎症定位与定量评估:PET/MRI融合成像分析

Localization and quantitative assessment of inflammation in frozen shoulder: a PET/MRI fusion imaging analysis.
PubMed 文献 · Skeletal Radiol · 2026-08-06

本研究对7例冻结期冻结肩患者行18F-FDG PET/CT与MRI配准融合分析,以无症状对侧肩SUVmax为参考阈值。结果显示炎症集中于盂唇前上与前下部,所有患者盂唇SUVmax最高,且面积加权SUV随距盂唇距离增大而下降。

要点

  • 冻结肩炎症活性最高部位为盂唇前上及前下部,阅片时应重点关注盂唇区域。
  • 以对侧无症状肩SUVmax作为个体化参考阈值,有助于判断患侧异常代谢增高。
  • 面积加权SUV随距盂唇距离增大而递减,提示远离盂唇区域炎症强度下降。

核心结论

  • 炎症定位于盂唇前上及前下部,提示盂唇为冻结肩炎症活动的优先部位。
  • FDG摄取最恒定出现在盂唇,所有患者盂唇均显示最高SUVmax。

研究设计与样本

  • 研究类型为前瞻性观察性PET/MRI融合成像分析,共纳入7例冻结期冻结肩患者。
  • 样本为2男5女,平均年龄59岁,均处于冻结期,行18F-FDG PET/CT检查。
  • 将PET/CT与MRI数据集进行配准,以无症状对侧肩SUVmax作为参考阈值。
  • 在T2加权斜矢状位图像上评估以盂唇为中心的9个层面,并在盂唇层面按时钟法测量径向SUVmax。

关键影像表现/征象

  • 面积加权SUV在盂唇处达峰值,并随距盂唇距离增大而降低(ρ = -0.709,p < 0.0001)。
  • SUVmax在盂唇前上部和前下部最高。
  • 所有患者中,盂唇均表现为FDG摄取最恒定的部位,且SUVmax最高。
  • 无症状对侧肩平均SUVmax为1.6 ± 0.3。

诊断标准与关键数值

  • 以无症状对侧肩SUVmax作为判断炎症活性增高的参考阈值。
  • 面积加权SUV计算公式为阈值以上面积乘以平均SUV。
  • 比较了肩袖间隙、喙肱韧带、腋囊和盂唇的SUVmax,盂唇最高。
  • SUVmax与距盂唇距离呈负相关(ρ = -0.709,p < 0.0001)。

临床应用与阅片要点

  • 阅片时对冻结肩患者应重点观察盂唇前上与前下部有无FDG高摄取。
  • 可采用对侧无症状肩SUVmax作为个体化对照,帮助判断患侧代谢异常。
  • 融合成像有助于将代谢增高区准确定位到盂唇结构,避免将邻近结构误判为炎症部位。

局限性

  • 样本量较小,仅7例患者,且均为冻结期病例。
  • 原文未提及对照组设计或多中心数据,结果的普适性可能有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND OBJECTIVE: Frozen shoulder is a common clinical condition; however, its pathophysiology and precise anatomical localization of inflammatory activity remain unclear. This study was aimed at identifying the localization and intensity of inflammation in patients with frozen shoulder using PET/MRI fusion imaging.

PATIENTS AND METHODS: Seven patients with frozen shoulder who underwent 18F-FDG PET/CT were analyzed (2 men, 5 women; mean age, 59 years), all in the freezing phase. PET/CT and MRI datasets were coregistered, and standardized uptake values (SUVs) were obtained. The SUVmax of the asymptomatic contralateral shoulder served as the reference threshold. On T2-weighted oblique sagittal images, nine slices centered on the labrum were evaluated. Area-weighted SUV was calculated as the product of the area above threshold and mean SUV. On the labral slice, SUVmax was measured radially using a clockface-based method. SUVmax values of the rotator interval, coracohumeral ligament, axillary recess, and glenoid labrum were compared.

RESULTS: The mean SUVmax of the asymptomatic shoulder was 1.6 ± 0.3. Area-weighted SUV peaked at the glenoid labrum and decreased with distance (ρ = - 0.709, p < 0.0001). SUVmax was highest in the anterosuperior and anteroinferior labrum. FDG uptake was most consistently observed at the glenoid labrum, which showed the highest SUVmax in all patients.

DISCUSSION: Inflammation was localized to the anterosuperior and anteroinferior glenoid labrum, suggesting the labrum as a preferential site of inflammatory activity. These findings provide insight into disease mechanisms and support further imaging studies focusing on the labrum.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kimura, Yamamoto, Koibuchi, et al. Localization and quantitative assessment of inflammation in frozen shoulder: a PET/MRI fusion imaging analysis. Skeletal Radiol. 2026. PMID: 42560481. doi:10.1007/s00256-026-05332-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。