文献速递儿科影像外周血管US

超快剪切波弹性成像评估儿童深静脉血栓的前瞻性可行性研究

Ultrafast shear-wave elastography for pediatric deep vein thrombosis: a prospective feasibility study.
PubMed 文献 · Pediatr Radiol · 2026-08-04

本研究为单中心前瞻性研究,纳入35例超声确诊深静脉血栓的儿童患者,使用研究平台和6.9MHz线阵探头行床旁超快剪切波弹性成像。结果显示剪切波速度随时间增加,平均每天增加0.012 m/s(P<0.001),提示超快剪切波弹性成像可作为儿童血栓成熟度的无创定量生物标志物。

要点

  • 超快剪切波弹性成像在年长儿童和闭塞性深静脉血栓中成功率更高。
  • 剪切波速度随血栓时间推移而增加,可用于判断血栓成熟度。
  • 年长和女性患儿剪切波速度更高,解读时需考虑年龄与性别因素。

核心结论

  • 超快剪切波弹性成像在儿童深静脉血栓中具有可行性,尤其在年长患者和闭塞性血栓中成功率更高。
  • 探索性纵向分析显示剪切波速度随时间增加,平均每天增加0.012 m/s(P<0.001)。
  • 年长发病和女性与剪切波速度增高相关,且独立于血栓发病时间。

研究设计与样本

  • 单中心前瞻性可行性研究,纳入35例超声确诊深静脉血栓的儿童患者(<18岁)。
  • 患者中位年龄1.4岁(范围0.0–17.6岁),63%为男性。
  • 使用研究平台(Vantage-256,Verasonics)和6.9MHz线阵探头行床旁剪切波弹性成像,剪切波速度用MATLAB计算。
  • 计划在诊断后0–5天、6天–6周、6–16周三个时间点进行弹性成像评估。

关键影像表现/征象

  • 闭塞性深静脉血栓较非闭塞性血栓更易获得剪切波速度测量。

诊断标准与关键数值

  • 可行性定义为能够获得剪切波速度测量值。
  • 剪切波速度随时间增加的速率为平均每天0.012 m/s(P<0.001)。

临床应用与阅片要点

  • 对年长儿童和闭塞性深静脉血栓患者可优先尝试剪切波弹性成像评估血栓硬度。
  • 随访时对比同一血栓的剪切波速度变化时,需考虑患儿年龄和性别的独立影响。

局限性

  • 本研究为单中心设计,样本量有限,仅有19例成功获得弹性成像数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of ultrafast shear-wave elastography (SWE) for quantifying thrombus stiffness in pediatric deep vein thrombosis (DVT), and to explore changes over time.

MATERIALS AND METHODS: In this single-center prospective study, pediatric patients (<18 years) with ultrasound-confirmed DVT were prospectively enrolled. Bedside SWE ultrasound was performed using a research platform (Vantage-256, Verasonics, Kirkland, Washington, USA) with a 6.9-MHz linear transducer. Mean shear-wave velocity was computed using MATLAB software. To assess shear-wave velocity (SWV) changes over time (exploratory analysis), SWE was planned at three timepoints (0-5 days, 6 days-6 weeks, and 6-16 weeks from DVT diagnosis). Feasibility was defined as the ability to obtain SWV measures. Changes in SWV over time in patients with ≥2 successful SWE were estimated using generalized estimating equations. The model was adjusted for patient age at DVT and sex.

RESULTS: In total, 35 patients (median age 1.4 years [range, 0.0-17.6], 63% male) were enrolled. SWE was successful in 19 patients, with a higher frequency of success in older patients and in occlusive DVTs. Fifteen of the 19 patients had ≥2 SWE. We documented an increase in SWV over time, with an increase in mean velocity of 0.012 m/s per day (P<0.001). Older age at DVT and female sex were associated with increased SWV, independent of time from index DVT.

CONCLUSIONS: Ultrafast SWE was feasible in pediatric DVT, particularly in older patients and in those with occlusive DVT. In exploratory longitudinal analyses, SWV increased over time, supporting further investigation of ultrafast SWE as a non-invasive quantitative biomarker of thrombus maturation in children.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Aguet, Fakhari, Mertens, et al. Ultrafast shear-wave elastography for pediatric deep vein thrombosis: a prospective feasibility study. Pediatr Radiol. 2026. PMID: 42550209. doi:10.1007/s00247-026-06733-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。