文献速递乳腺乳腺X线

DBT+DM与单纯DM筛查后间期癌的影像学回顾分析

Radiological review of interval breast cancers following screening with DBT + DM or DM: results from MAITA project randomized trials.
PubMed 文献 · Radiol Med · 2026-08-04

本研究比较了数字乳腺断层合成(DBT)+数字乳腺X线摄影(DM)与单纯DM筛查后发生间期乳腺癌的筛查影像特征。三位放射科医师仅阅读DM图像,另三位阅读全部可用图像,将间期癌按检出异常医师人数分为真阴性、轻微征象和假阴性。结果提示两组间期癌的影像学特征相似,DBT对间期癌发生数量和类型的影响均较小。

要点

  • DBT+DM与单纯DM筛查后间期癌的影像学特征相似,阅片时无需因筛查模式不同而改变对间期癌的评判预期。
  • 间期癌按检出异常人数分为真阴性、轻微征象、假阴性三类,此分类可辅助回顾性分析筛查漏诊原因。
  • DBT+DM对间期癌数量和类型的影响均较小,不应因采用DBT而放松对间期癌的警惕与随访管理。

核心结论

  • DBT+DM与单纯DM筛查后间期癌的影像学特征相似,DBT对间期癌发生数量和类型的影响均较小。

研究设计与样本

  • 研究设计为来自两项比较DBT+DM与DM筛查的随机试验的回顾性影像分析。
  • 共纳入91例间期癌筛查前影像(DBT+DM组43例,DM组48例)及190例阴性对照(分别为94例和96例)。
  • 三位放射科医师仅阅读DM筛查图像,另三位阅读全部可用图像(实验组为DBT和DM,标准组为DM)。
  • 间期癌按检出异常的医师人数分类为:真阴性(三位均判阴性)、轻微征象(仅一位判阳性)、假阴性(两位或三位判阳性)。

诊断标准与关键数值

  • 仅阅读DM图像时,DBT组间期癌分类比例为真阴性40%、轻微征象21%、假阴性40%。
  • 阅读DBT和DM全部图像时,DBT组间期癌分类比例为真阴性30%、轻微征象28%、假阴性42%。
  • 仅阅读DM图像时,DM组间期癌分类比例为真阴性29%~42%、轻微征象31%~35%、假阴性27%~35%。
  • 两组间各分类比例的差异与随机波动相容。

临床应用与阅片要点

  • 回顾分析间期癌时,可采用真阴性、轻微征象、假阴性三级分类评估筛查漏诊情况。
  • 阅读DBT筛查图像时,间期癌的漏诊特征与DM相似,应保持相同的警惕性。

局限性

  • 本研究为回顾性影像分析,间期癌样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Compare the radiological characteristics of screening images preceding interval cancers that occurred in women screened with digital breast tomosynthesis (DBT) plus digital mammography (DM) vs. those in women screened with DM alone.

MATERIALS AND METHODS: From two randomized trials comparing DBT + DM vs. DM, 91 (43 from DBT + DM arm and 48 from DM arm) images preceding interval cancers and 190 (94 and 96, respectively) negative controls were reviewed by three radiologists using only DM screening mammograms and by three different radiologists using all available images, i.e. DBT and DM for the experimental arm and DM for the standard arm. The cancers were classified according to the number of reviewers that found abnormalities, as true negative (negative for all three reviewers), minimal sign (positive for one and negative for two), and false negative (positive for two or three reviewers).

RESULTS: In the DM arm, interval cancers were classified as true negative in 29-42%, minimal signs in 31-35%, and false negative in 27-35%; in the DBT arm, the proportion of true negative was 40%, minimal signs 21%, and false negatives 40% when the review was performed using only DM images, 30%, 28%, and 42% when the reviewers read both DBT and DM screening images. The differences were compatible with random fluctuations.

CONCLUSION: The radiological analysis of interval cancers after DBT + DM and after DM alone showed similar characteristics, confirming that the impact of DBT on interval cancer incidence is small both in terms of quantity and type.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Iotti, Frigerio, Mancuso, et al. Radiological review of interval breast cancers following screening with DBT + DM or DM: results from MAITA project randomized trials. Radiol Med. 2026. PMID: 42550460. doi:10.1007/s11547-026-02267-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。