CT上消化道方案检测胃十二指肠漏的诊断价值
以外科所见和临床随访为参考标准,结果显示该方案敏感度87%、特异度98%、PPV92%、NPV97%,对胃十二指肠漏具有高特异度和高阴性预测值。
要点
- 阳性病例中腔外对比剂、积气、积液出现率分别为75%、78%、72%,腔外对比剂特异性高。
- 该CT方案阴性预测值97%,报告未见腔外对比剂时基本可排除胃十二指肠漏。
- 确诊漏者住院时间与影像检查次数显著高于无漏者,应及时提示临床。
核心结论
- 该CT上消化道方案对胃十二指肠漏检测具有高特异度(98%)和高阴性预测值(97%),可用于疑诊及常规术后漏评估。
研究设计与样本
- 扫描前30分钟及扫描前即刻分两次口服阳性对比剂,采集仰卧位和右侧卧位CT图像。
- 以外科所见和临床随访作为参考标准,记录检查指征与CT表现并计算诊断效能。
关键影像表现/征象
- 阳性检查中腔外对比剂出现率为75%,阴性检查为0%,是提示漏的直接征象。
- 阳性检查中腔外积气出现率为78%,阴性检查为44%,单纯积气鉴别价值有限。
- 阳性检查中腔外积液出现率为72%,阴性检查为24%,需结合对比剂外溢判断。
诊断标准与关键数值
- 以手术及临床随访为参考标准,该CT上消化道方案敏感度87%、特异度98%、阳性预测值92%、阴性预测值97%。
- 184次检查中20%(36次)为阳性结果,不同征象在阳性与阴性检查中的出现率如上所述。
临床应用与阅片要点
- 报告时应重点寻找腔外对比剂,其阴性检查出现率为0%,是最具特异性的影像表现。
- 腔外积气在阴性检查中也可出现(44%),不要仅凭积气诊断吻合口漏。
- 右侧卧位与仰卧位双体位联合双期口服对比剂有利于显示胃十二指肠区域微小漏口。
局限性
- 本研究为回顾性单中心设计,存在选择偏倚与记录偏倚可能。
- 外科与临床随访并非所有患者均接受,部分结果可能受参考标准不完整影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of a novel CT upper gastrointestinal (UGI) protocol for detecting gastroduodenal leaks in patients who would typically undergo fluoroscopic UGI (fUGI).
METHODS: In this retrospective cohort study, adult patients undergoing CT UGI between June 2022 and September 2025 were included. The protocol involved biphasic positive oral contrast administration 30 min and immediately prior to CT scanning in supine and right lateral decubitus positions. Study indication and CT findings were documented retrospectively; surgical findings and clinical follow-up served as reference standards. Sensitivity, specificity, PPV, and NPV were calculated. Mann-Whitney U tests compared length of stay (LOS) and imaging utilization by leak status.
RESULTS: One hundred fifty-seven patients (184 exams; mean age 62.8 ± 13.8 years; 86 females) were included; 93% of exams were performed for suspected leak. Sensitivity, specificity, PPV, and NPV were 87%, 98%, 92%, and 97%, respectively. Among positive exams (36/184, 20%), extraluminal contrast, gas, and fluid collection were present in 75%, 78%, and 72% of cases versus 0%, 44%, and 24% in negative exams. Patients with confirmed leaks had significantly longer median LOS (26 vs. 8 days, p < 0.001) and greater imaging utilization (median 12 vs. 4 exams, p < 0.001).
CONCLUSION: This CT UGI protocol demonstrates high specificity and NPV for gastroduodenal leak detection, supporting its utility for both suspected and routine postoperative leak evaluation.
引用
- Moeller, Lee, Lubner, et al. Diagnostic utility of a CT upper gastrointestinal protocol for the detection of gastroduodenal leaks. Abdom Radiol (NY). 2026. PMID: 42545483. doi:10.1007/s00261-026-05635-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。