儿科患者友好型放射报告的家庭使用与接受度
在两个学术型儿童医院通过患者门户提供交互式患者友好型放射报告,统计391713例影像检查的查看数据并调查家属体验。标准报告查看率为50.5%,患者友好型报告查看率仅9.0%,但占已查看标准报告的17.7%。结果提示该工具初步使用率较低,但提供儿科患者友好型报告可行且可能改善主观理解。
要点
- 患者友好型报告查看率低,但占已查看标准报告的17.7%,提示有特定接受群体
- X线摄影报告的查看率低于其他模态的汇总查看率
- 提供患者友好型交互式报告在儿科可行,可能改善家属对报告的主观理解
核心结论
- 提供患者友好型交互式放射报告对儿科患者可行,尽管初步使用率较低,但可能改善对放射报告的主观理解
研究设计与样本
- 通过患者门户使用商用软件提供患者友好型交互式放射报告,并获取门户使用统计数据
- 对家属进行问卷调查以评估报告使用体验和理解程度
关键影像表现/征象
- 标准报告查看率为50.5%,患者友好型报告查看率为9.0%
- 患者友好型报告查看量占已查看标准报告的17.7%
- X线摄影报告的患者友好型报告查看率低于其他模态的汇总查看率
- 家属平均花费3.29分钟查看每份患者友好型报告,95%CI为3.25至3.32分钟
诊断标准与关键数值
- 患者友好型报告的查看率定义为查看患者友好型报告的检查数占全部检查数的比例
- 平均查看时间为3.29分钟,95%CI为3.25至3.32分钟
临床应用与阅片要点
- 患者友好型报告可嵌入患者门户并配合通俗语言解释和交互式图示辅助家属理解
- 报告查看情况可通过门户使用统计追踪,便于评估实际使用而非仅靠主观反馈
- 其中一个儿童医院的专项措施使患者友好型报告查看率出现持续上升
局限性
- 总体患者友好型报告查看率仅9.0%,实际使用受限
- 研究在两个学术型儿童医院开展,可能影响外推性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The Cures Act Final Rule requires that patients have real-time access to their radiology reports, which contain terminology meant to communicate between healthcare providers and may be difficult for patients and families to comprehend.
OBJECTIVE: To evaluate family use of and experience with patient-friendly radiology reports provided through a patient portal for the pediatric population.
MATERIALS AND METHODS: Patient-friendly interactive radiology reports were made available to all patients and families with imaging exams performed from January 2024 through November 2025 at two children's health systems via a patient portal using commercially available software. Portal usage statistics were obtained, including report access rate and report view time of plain language explanations and interactive diagrams. Families were surveyed to assess experience with the reports and report comprehension.
RESULTS: A total of 391,713 combined imaging exams were performed between the two institutions during the study period, of which 50.5% of standard reports were viewed. While only 9.0% of patient-friendly reports were viewed, this accounted for 17.7% of viewed standard reports. Reports of radiographs were accessed less than the pooled rates of other modalities. Families spent an average of 3.29 min (95% CI 3.25-3.32 min) viewing each patient-friendly report. An initiative at one children's hospital led to a sustained increase in view rates of patient-friendly reports.
CONCLUSION: Results suggest that while initial utilization of the tool was low, providing patient-friendly interactive radiology reports is feasible for pediatric patients and may improve subjective comprehension of radiology reports.
引用
- Johnston, Gatidis, Fong, et al. Assessing family engagement and acceptance of patient-friendly radiology reports at two academic children's hospitals. Pediatr Radiol. 2026. PMID: 42545473. doi:10.1007/s00247-026-06738-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。