文献速递骨肌MRCT

CT样3D-mFFE MRI序列诊断腕部骨折并与CBCT比较

Diagnostic performance of a computed tomography (CT)-like 3D- multiecho fast field echo (mFFE) magnetic resonance imaging (MRI) sequence for acute wrist fractures: comparison with cone-beam computed tomography (CT).
PubMed 文献 · Clin Radiol · 2026-07-11

本研究回顾性纳入66例近期腕部创伤疑诊骨折患者,由两名肌骨放射科医师独立评估CBCT和3D-mFFE CT样MRI图像,以第三名放射科医师共识为参考标准。结果显示3D-mFFE序列对骨折检测的敏感度、特异度和准确度与CBCT相近,对粉碎和移位的判断一致性为强至极强。

要点

  • 3D-mFFE MRI对腕部骨折检测特异度高达0.99-1.00,报告阳性骨折较可靠。
  • MRI序列与参考标准对粉碎和移位的判断一致性为强至极强,可描述骨折形态。
  • 该序列可整合进标准MRI方案,实现无辐射一站式骨折检出与形态评估。

核心结论

  • CT样3D-mFFE MRI序列对腕部骨折形态学评估的诊断效能与CBCT相当。
  • 将3D-mFFE纳入标准MRI方案,可在单次无辐射检查中同时完成骨损伤检出和表征。

研究设计与样本

  • 两名肌骨放射科医师独立评估CBCT与3D-mFFE CT样MRI图像。
  • 以第三名放射科医师的共识判读作为参考标准。

关键影像表现/征象

  • 66例患者中38例共检出63处创伤性骨损伤,发生率为58%。

诊断标准与关键数值

  • 3D-mFFE序列损伤检测敏感度、特异度、准确度:R1为0.62、0.99、0.96,R2为0.60、1.00、0.96。
  • CBCT损伤检测敏感度、特异度、准确度:R1为0.68、1.00、0.97,R2为0.70、1.00、0.97。
  • 3D-mFFE序列与参考标准对粉碎的判断一致性κ=0.69-0.87,对移位的判断一致性κ=0.63-0.92。

临床应用与阅片要点

  • 3D-mFFE序列特异度高,阅片中阳性骨折判读可信度较高。
  • 对粉碎和移位的评估可参照CBCT的诊断思路用于腕部骨折MRI报告。

局限性

  • 该研究为单中心回顾性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Accurate detection and characterizstion of wrist fractures are essential for optimal management of wrist trauma. This study aimed to evaluate the diagnostic performance of a computed tomography (CT)-like 3D-multiecho fast field echo (mFFE) magnetic resonance imaging (MRI) sequence for the detection and morphological characterisation of traumatic wrist fractures compared with cone-beam computed tomography (CBCT).

MATERIALS AND METHODS: This retrospective study included 66 patients with recent wrist trauma and suspected fracture between October 2022 and September 2023. Two musculoskeletal radiologists (R1 and R2) independently reviewed CBCT and 3D-mFFE CT-like MRI images. The diagnostic performance of the 3D-mFFE sequence for detecting and characterising traumatic bone injuries was assessed using a consensus interpretation by a third radiologist (R3) as the reference standard.

RESULTS: Sixty-three traumatic bone injuries were identified in 38 of the 66 patients (58%). For injury detection with the 3D-mFFE sequence, sensitivity, specificity, and accuracy were 0.62, 0.99, and 0.96 for R1 and 0.60, 1.00, and 0.96 for R2. For CBCT, sensitivity, specificity, and accuracy were 0.68, 1.00, and 0.97 for R1 and 0.70, 1.00, and 0.97 for R2. Agreement between the 3D-mFFE sequence and the reference standard for fracture characterisation was strong to near perfect for both comminution (κ = 0.69-0.87) and displacement (κ = 0.63-0.92).

CONCLUSION: The CT-like 3D-mFFE MRI sequence demonstrated diagnostic performance comparable to CBCT for the morphological assessment of wrist fractures. When incorporated into a standard MRI protocol, this sequence may allow both detection and characterisation of traumatic bone injuries within a single, radiation-free examination.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Willaume, Tochon, Martins, et al. Diagnostic performance of a computed tomography (CT)-like 3D- multiecho fast field echo (mFFE) magnetic resonance imaging (MRI) sequence for acute wrist fractures: comparison with cone-beam computed tomography (CT). Clin Radiol. 2026. PMID: 42541940. doi:10.1016/j.crad.2026.107435

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。