增强结肠超声造影在肛门直肠畸形评估中的价值
本研究纳入72例肛门直肠畸形患儿,以外科术中所见为参考标准,比较术前增强结肠超声造影与X线结肠造影的诊断效能。结果显示增强结肠超声造影瘘管检出敏感度(98.6%)及与外科解剖一致率(98.6%)均高于X线结肠造影(分别为83.3%、73.6%)。增强结肠超声造影可区分直肠膜部与直肠球部尿道瘘,P-P值或有助于选择手术方式。
要点
- 增强结肠超声造影瘘管检出敏感度98.6%,显著高于X线结肠造影83.3%(P<0.001)
- 直肠球部尿道瘘患儿P-P截断值23.5 mm时AUC为0.747(敏感度66.7%,特异度76.0%)
- 增强结肠超声造影与外科解剖一致率98.6%,可用于指导腹腔镜辅助肛门成形术选择
核心结论
- 增强结肠超声造影是评估肛门直肠畸形术前结构信息的安全、有效且多用途的方法
- 对直肠尿道瘘患者,增强结肠超声造影可进一步区分直肠膜部与直肠球部尿道瘘
- 特定病例中P-P测量可能有助于选择合适的手术方式
研究设计与样本
- 研究类型为诊断准确性对照研究,共纳入72例肛门直肠畸形病例,外科术中所见为参考标准
- 对比术前增强结肠超声造影与X线透视结肠造影的诊断效能,同时评估手术方式与直肠尿道瘘参数的关系
关键影像表现/征象
- 增强结肠超声造影可显示瘘管连接及肛门直肠畸形相关结构,区分直肠膜部与直肠球部尿道瘘
- 瘘管检测需以超声造影剂注入结肠后进行实时高分辨率成像进行评估
诊断标准与关键数值
- 瘘管检出敏感度:增强结肠超声造影98.6%,X线结肠造影83.3%,P<0.001
- 与外科解剖一致率:增强结肠超声造影98.6%,X线结肠造影73.6%
- 直肠球部尿道瘘患者P-P截断值23.5 mm时,敏感度66.7%,特异度76.0%,AUC为0.747,P=0.01,95% CI 0.589-0.904
临床应用与阅片要点
- 增强结肠超声造影可作为肛门直肠畸形术前评估的替代检查,避免电离辐射及镇静需求
- 对直肠球部尿道瘘患者可利用P-P截断值23.5 mm辅助判断是否适合腹腔镜辅助肛门成形术
- 阅片时应重点观察有无瘘管、瘘管走行及与尿道的关系,报告时注明P-P测量值
局限性
- 原文未报告多中心前瞻性设计、随机化及盲法执行情况
- 原文未报告不同操作者间一致性与设备参数对测量结果的影响
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Anorectal malformations are common congenital anomalies. Accurate preoperative imaging of fistulous connections is crucial for surgical planning. Traditional imaging uses ionizing radiation and often requires sedation. Contrast-enhanced colosonography, based on the application of ultrasound contrast agents, has been developed to overcome these limitations while still providing high-resolution structural information for the evaluation of anorectal malformations. The indications of laparoscopically assisted anorectoplasty for recto-bulbar urethral fistulas remain debated.
OBJECTIVES: This study aimed to evaluate the diagnostic accuracy of contrast-enhanced colosonography in detecting anorectal malformations and its value in guiding surgical approach selection.
MATERIALS AND METHODS: The diagnostic performance of preoperative contrast-enhanced colosonography and fluoroscopic colostography was compared in 72 cases, with surgical findings serving as the reference standard. Additionally, the relationship between surgical approach and the data from recto-urethral fistula was evaluated.
RESULTS: Contrast-enhanced colosonography showed higher sensitivity for fistula detection rate than fluoroscopic colostography (98.6% vs. 83.3%, P<0.001). Concordance with surgical anatomy was 98.6% for contrast-enhanced colosonography, while 73.6% for fluoroscopic colostography. Among patients with recto-bulbar urethral fistula, a pouch-perineum (P-P) cutoff value of 23.5 mm (sensitivity 66.7%, specificity 76.0%) yielded an area under the curve of 0.747 (P=0.01, 95% CI 0.589-0.904).
CONCLUSION: Contrast-enhanced colosonography appears to be a safe, effective, and versatile method for obtaining critical preoperative structural information in patients with anorectal malformations. For patients with recto-urethral fistulas, contrast-enhanced colosonography enables further differentiation between recto-membranous and recto-bulbar urethral fistulas. In specified cases, the P-P measurement may be helpful in selecting the appropriate surgical approach.
引用
- Deng, Lin, Ding, et al. Value of contrast-enhanced colosonography in the assessment of anorectal malformations. Pediatr Radiol. 2026. PMID: 42530580. doi:10.1007/s00247-026-06715-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。