临床SVR重建中胎儿脑自动分割的评估
本研究回顾性纳入70例接受胎儿MRI并完成SVR重建的孕妇,评估自动胎儿脑分割及容积测量替代手工二维测量的可行性。结果显示70%病例分割质量良好,分割质量差的胎儿胎龄显著更低。自动容积测量与临床二维径线呈强正相关,提示其有临床应用潜力。
要点
- 胎儿SVR自动分割在多数病例中可行,胎龄越低分割失败风险越高。
- 脑容积与BPD、FOD及小脑横径等二维测量强相关。
- 自动容积测量未来可能替代部分手工二维径线测量。
核心结论
- 胎儿脑SVR自动分割在多数病例中成功,生成的容积测量与手工二维测量强相关,可能成为临床实践中的实用替代方法。
研究设计与样本
- 回顾性、IRB批准研究,纳入70例接受临床胎儿MRI及SVR的孕妇,平均胎龄28.2±4.3周。
- 以2D T2-SSFSE图像作为SVR输入,层厚2.5或3mm,重叠1.25或1.5mm,最多5个成像平面,每平面含2次独立采集。
- SVR管道采用Philips Research Imaging Development Environment实现,分割图及容积测量通过网络平台自动提供。
关键影像表现/征象
- 分割图按3分制评分(0=差,1=尚可,2=好),多数患者(70%,49/70)分割质量良好。
- 12/70(17.1%)患者分割图质量差,其平均胎龄25.1±4.1周,显著低于其余胎儿28.9±4.1周(p=0.004)。
诊断标准与关键数值
- 幕上脑容积与线性双顶径相关系数r=0.94,与额枕径r=0.92。
- 全小脑容积与横小脑径相关系数r=0.92。
- 全脑干容积与脑桥前后径相关系数r=0.88。
- 总SVR重建时间(含容积分析)为8.6±3.4分钟,与胎龄呈正相关(r=0.78)。
临床应用与阅片要点
- 自动分割图质量良好时,容积测量可用于辅助胎儿脑结构评估,报告时仍需核对分割边界。
- 对低胎龄胎儿应警惕自动分割失败,需保留并核对二维径线测量结果。
局限性
- 研究为回顾性设计,未报告自动与手动SVR分割结果的一致性验证细节。
- 分割失败的病例未进一步分析具体失败原因及序列或扫描条件影响因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the potential for automatically derived volumetric data sets in slice to volume reconstruction (SVR) MRI images of the fetal brain to replace manually acquired 2D brain measurements in clinical practice.
MATERIALS AND METHODS: This retrospective, IRB approved study included pregnant women undergoing fetal MRI with SVR. In addition to performing the standard of care fetal MRI protocol, 2D T2-SSFSE images were also collected at 2.5 or 3 mm slice thickness with 1.25 mm or 1.5 mm overlap in up to 5 imaging planes (2 independent/separate acquisitions per imaging plane) and used as inputs for SVR. The SVR pipeline was implemented using the Philips Research Imaging Development Environment (PRIDE) and the resulting color-coded brain segmentation maps and associated volumetric measurements were made available automatically through a web-based platform. Segmentation maps were rated on a 3-point scale for accuracy by the study radiologists (0 = poor, 1 = fair, 2 = good). 2D measurements from the clinical radiology reports were extracted and compared with the automated volumetric measurements.
RESULTS: SVR was performed in 70 patients undergoing clinical fetal MRI (28.2 ± 4.3 weeks gestational age). Total SVR reconstruction time, including volumetric analysis, was 8.6 ± 3.4 minutes, which positively correlated with gestational age (r = 0.78). Segmentation quality was judged to be good in the majority of patients (70%, 49/70). 17.1% (12/70) of patients were considered to have poor segmentation map quality. The mean gestational age of these fetuses was significantly lower (25.1 ± 4.1 weeks) than the remaining fetuses (28.9 ± 4.1, p=0.004). Multiple strong positive correlations were observed between the linear measurements and the volumetric measurements including, a) the supratentorial brain volume with the linear brain biparietal diameter (r=0.94) and fronto-occipital diameter (r=0.92), b) total cerebellar volume with the transverse cerebellar diameter (r=0.92) and c) the total brainstem volume with the anterior-posterior pons measurement (r=0.88).
CONCLUSIONS: Automated fetal brain segmentation in SVR is successful in the majority of cases, and the associated generated volumetric measurements are strongly correlated with manual 2D measurements, suggesting that they may eventually serve as a practical alternative in clinical practice.
引用
- Nagaraj, Greer, Tkach, et al. Automated Fetal Brain Segmentation in Slice to Volume Reconstruction in Clinical Practice. AJNR Am J Neuroradiol. 2026. PMID: 42527306. doi:10.3174/ajnr.A9552
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。