文献速递腹部US

超分辨率超声显微镜评估胰腺导管腺癌微血管组学

Super-resolution ultrasound microscopy profiles microvasculomics of pancreatic ductal adenocarcinoma with pathological association and facilitates differential diagnosis.
PubMed 文献 · Radiol Med · 2026-07-30

结果显示SR-US微血管参数与病理微血管密度(pMVD)存在显著相关性,微血管比值鉴别PDAC与PNET的AUC最高达0.976。

要点

  • SR-US微血管比值鉴别PDAC与PNET的AUC最高达0.976,有助于两者术前鉴别
  • 分支型或点状微血管形态的PDAC患者pMVD显著低于弥漫紊乱型(P=0.010)
  • 微血管比值、微血管复杂度、流速及灌注指数均与pMVD显著相关(均P<0.05)

核心结论

  • SR-US可无创评估PDAC微血管组学特征,其微血管参数与病理微血管密度存在相关性,并具有定量鉴别PDAC与PNET的价值。

研究设计与样本

  • 另纳入12例PNET患者仅用于鉴别诊断分析,以病理微血管密度作为参考标准进行相关性验证。

关键影像表现/征象

  • PDAC微血管比值中位数为22.88%(16.74%,27.13%),微血管复杂度中位数为1.60(1.53,1.65)。
  • PDAC灌注指数中位数为2.93(2.05,3.65),反映微血管血流灌注水平。
  • 分支型或点状微血管形态的PDAC患者pMVD显著低于弥漫紊乱型(P=0.010)。

诊断标准与关键数值

  • SR-US微血管比值鉴别PDAC与PNET的AUC最高达0.976。
  • pMVD与微血管比值、微血管复杂度、平均/最大/最小微血管流速及灌注指数均显著相关(均P<0.05)。
  • PDAC微血管比值中位数22.88%(16.74%,27.13%),微血管复杂度中位数1.60(1.53,1.65),灌注指数中位数2.93(2.05,3.65)。

临床应用与阅片要点

  • SR-US可通过微血管形态分型提示PDAC的病理微血管密度,分支型或点状型提示较低pMVD。
  • 微血管比值具较高鉴别效能,可用于PDAC与PNET的定量鉴别辅助诊断。
  • 报告SR-US时可描述微血管形态类型及微血管比值、复杂度、灌注指数等参数以辅助临床决策。

局限性

  • PNET组样本量仅12例且仅用于鉴别诊断,未纳入主要分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To identify the microvasculomic profiles of PDAC through SR-US, study the correlation between SR-US characteristics and pathological microvascular density (pMVD), and preliminarily explore the differential diagnostic value of pancreatic SR-US.

MATERIALS AND METHODS: We prospectively performed SR-US examinations for PDAC patients from August 2024 to June 2025. SR-US microvascular maps were reconstructed, and SR-US microvascular parameters were measured. pMVD was calculated, and the correlation between pMVD and SR-US characteristics was validated with Spearman correlation analysis. The differential diagnostic value of SR-US was analyzed by its capacity to differentiate PDAC and pancreatic neuroendocrine tumors (PNET), another common solid tumor of the pancreas, with the area under the curve (AUC) calculated.

RESULTS: Seventy-two PDAC patients (median age: 64.00 years; 40 men) were enrolled for analysis, and 12 PNET patients were enrolled only for differential diagnosis. Thirty-seven (51.39%) PDAC showed a branch-type microvascular morphology. The medians of microvascular ratio, microvascular complexity, and perfusion index were 22.88% (16.74%, 27.13%), 1.60 (1.53, 1.65), and 2.93 (2.05, 3.65). PDAC patients with branch-type or dot-type microvasculature showed significantly lower pMVD than those with diffuse chaotic microvasculature (p = 0.010). pMVD was significantly correlated with microvascular ratio; microvascular complexity; mean, max, and min microvascular velocity; and perfusion index (all p < 0.05). SR-US characteristics achieved effective differential diagnosis between PDAC and PNET with the highest AUC up to 0.976 for microvascular ratio.

CONCLUSION: SR-US enables noninvasive evaluation of the microvasculomic profile of PDAC with preliminary evidence of pathological correlation and quantitative diagnostic value to differentiate PDAC from PNET.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Yang, Huang, Zheng, et al. Super-resolution ultrasound microscopy profiles microvasculomics of pancreatic ductal adenocarcinoma with pathological association and facilitates differential diagnosis. Radiol Med. 2026. PMID: 42530771. doi:10.1007/s11547-026-02258-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。