文献速递心血管MR

固定反转时间单次激发黑血PSIR LGE用于心肌瘢痕快速检测

Single-shot blood-nulled PSIR LGE with fixed inversion time for rapid and reliable scar detection in cardiac MRI.
PubMed 文献 · Eur J Radiol · 2026-07-23

结果表明单次激发黑血LGE采集时间减少95%,瘢痕检出率与分类一致,VPS和VTS一致性极佳,可作为快速补充序列。

要点

  • 单次激发黑血LGE采集仅19秒,较常规分段白血LGE的375秒减少95%,适合不耐受屏气者。
  • 两种技术瘢痕检出患者数一致,17节段VPS和VTS高度相关,可用于日常替代或补充。
  • 固定TI为160ms,无需逐例手动优化TI,简化扫描流程并提升检查效率。

核心结论

  • 固定TI单次激发黑血LGE对心肌瘢痕的检出和特征描述与常规分段白血LGE相当,且采集时间增加极少,可作为快速补充序列使用。

研究设计与样本

  • 所有患者均接受1.5T下常规分段白血LGE和固定TI单次激发黑血LGE扫描,分段白血采用手动优化TI,单次激发黑血采用固定TI 160ms。
  • 采用美国心脏协会17节段模型、视觉存在评分VPS和视觉透壁程度评分VTS对短轴图像进行心肌瘢痕评估。

关键影像表现/征象

  • 心肌瘢痕在17节段模型下表现为节段性异常强化,需区分缺血性与非缺血性分布模式。
  • 缺血性心肌病可表现为心内膜下或透壁性强化,并沿冠状动脉供血区分布。
  • 非缺血性心肌病可表现为肌壁间、心外膜下或弥漫性强化,不沿单一冠脉供血区分布。

诊断标准与关键数值

  • 最终CMR诊断:缺血性心脏病11例,非缺血性心肌病25例,混合病因3例,正常CMR 27例。
  • 两种技术在26例患者中均检出LGE,患者层面检出率为39%,无分类不一致情况。
  • VPS为5.5±3.2对比5.2±3.2,VTS为14.5±10.9对比13.7±10.2,Spearman相关系数≥0.95。

临床应用与阅片要点

  • 单次激发黑血LGE可减少屏气配合困难或心律不齐患者的图像伪影,适合作为日常补充序列。
  • 固定TI无需逐例优化,可缩短检查流程,在临床工作量较大时优先考虑该序列。
  • 两种序列在VPS和VTS上高度一致,阅片时可参照同一17节段标准进行报告。

局限性

  • 本研究为单中心前瞻性设计,样本量相对较小,最终诊断为缺血性心脏病者仅11例。
  • 原文未提及与病理组织学或其他独立金标准的对照验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare conventional segmented white-blood (WB) late gadolinium enhancement (LGE) with fixed-inversion-time (TI) single-shot dark-blood (DB) LGE for myocardial scar assessment in patients with suspected ischemic or non-ischemic cardiomyopathy.

MATERIAL AND METHODS: In this prospective single-center study, consecutive patients undergoing cardiac magnetic resonance (CMR) between May 2023 and January 2024 for suspected ischemic or non-ischemic cardiomyopathy received both segmented WB LGE and single-shot DB LGE at 1.5 T. Segmented WB imaging used manually optimized TIs, single-shot DB imaging used a fixed TI of 160 ms. Short-axis stacks were assessed for presence, localization, transmurality, and pattern of LGE using the American Heart Association 17-segment model, Visual Presence Score (VPS; 0-17), and Visual Transmurality Score (VTS; 0-68).

RESULTS: Sixty-six patients (mean age 46 ± 16 years; 38% female) were included, with equal numbers referred for suspected ischemic and non-ischemic cardiomyopathy (n = 33 each). Final CMR diagnoses were ischemic heart disease in 11 patients (17%), non-ischemic cardiomyopathy in 25 (38%), mixed etiology in 3 (5%), and normal CMR in 27 (41%). Single-shot DB LGE required 95% less acquisition time (19 s vs. 375 s; p < 0.001). LGE was detected in 26 patients (39%) by both techniques; no discordant classifications. VPS and VTS showed excellent agreement between WB and DB (VPS: 5.5 ± 3.2 vs. 5.2 ± 3.2; VTS: 14.5 ± 10.9 vs. 13.7 ± 10.2; Spearman's ρ ≥ 0.95).

CONCLUSION: Fixed-TI single-shot DB LGE provides scar detectability and characterization comparable to conventional segmented WB LGE with minimal additional acquisition time, and may be used as a rapid complementary sequence.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kübler, Ledesma, Holtackers, et al. Single-shot blood-nulled PSIR LGE with fixed inversion time for rapid and reliable scar detection in cardiac MRI. Eur J Radiol. 2026. PMID: 42508277. doi:10.1016/j.ejrad.2026.113098

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。