文献速递泌尿生殖MR

多参数MRI组合优化用于慢性肾病早期检测

Optimization of Multiparametric MRI Sequence Combinations for Early Detection of Chronic Kidney Disease.
PubMed 文献 · Acad Radiol · 2026-07-25

本研究前瞻性纳入105例早期慢性肾病患者与127例健康对照,评估肾多参数MRI序列组合的诊断效能。

要点

  • DWI是早期慢性肾病检测中最重要的单一序列,单序列模型AUC可达0.874
  • T1WI+DWI组合在诊断性能与临床可行性间取得较好平衡,测试集准确率0.844
  • 皮质ADC变异度、髓质ADC变异度及ADC皮髓质差在模型中持续保留,阅片时应重点关注ADC不均质性

核心结论

  • 肾多参数MRI支持早期慢性肾病的无创检测,DWI是最重要的单一序列,多序列整合可提高诊断性能,T1WI+DWI在性能与可行性间取得实用平衡

研究设计与样本

  • 前瞻性研究,纳入105例早期慢性肾病患者和127例健康对照,按入组日期分为训练集和时间独立的测试集
  • 采用弹性网络正则化逻辑回归建立15个预定义模型,经五折交叉验证筛选代表性模型,并用ROC分析、校准分析、决策曲线分析和固定阈值诊断指标评估

关键影像表现/征象

  • 皮质ADC变异度、髓质ADC变异度及ADC皮髓质差在模型中被持续保留,提示肾脏ADC值不均匀性具有鉴别价值

诊断标准与关键数值

  • 特征重复性以组内相关系数评估为0.731至0.891,重复性可接受至良好
  • 训练集中四序列模型AUC最高为0.903,DWI单序列模型AUC为0.874,T1WI+DWI双序列模型AUC为0.884,T1WI+DWI+T1 mapping三序列模型AUC为0.895
  • 测试集中四序列模型AUC最高为0.866且校准最佳,T1WI+DWI的准确率和F1评分最高,分别为0.844和0.815

临床应用与阅片要点

  • 对疑似早期慢性肾病者,DWI所示ADC图肾皮髓质ADC变异度增大应引起警惕
  • 若需兼顾检查效率与诊断效能,可优先采用T1WI+DWI组合而非完整四序列方案

局限性

  • 研究人群为早期慢性肾病患者与健康对照,未包含其他肾脏疾病对照,临床鉴别诊断价值需进一步验证

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate renal multiparametric MRI sequence combinations for early chronic kidney disease (CKD) detection and identify an approach balancing performance and clinical feasibility.

METHODS: This prospective study included 105 patients with early CKD and 127 healthy controls. All participants underwent renal MRI with T1WI, DWI, T1 mapping, and BOLD imaging. Twenty four features were extracted from T1WI, ADC, T1, and R2* maps. Participants were divided into training and temporally independent test cohorts by enrollment date. Fifteen predefined models were developed using elastic net regularized logistic regression. Representative models were selected by fivefold cross validation and evaluated using ROC analysis, calibration analysis, decision curve analysis, and fixed threshold diagnostic metrics.

RESULTS: Feature reproducibility was acceptable to good, with intraclass correlation coefficients of 0.731 to 0.891. In training, the model using all four sequences achieved the highest AUC of 0.903. DWI was the best single sequence model (AUC, 0.874), T1WI+DWI was the best two sequence model (AUC, 0.884), and T1WI+DWI+T1 mapping was selected as the representative three sequence model (AUC, 0.895). Cortical ADC variability, medullary ADC variability, and ADC corticomedullary difference were consistently retained. In the test cohort, the model using all four sequences showed the highest AUC of 0.866 and the best calibration. T1WI+DWI achieved the highest accuracy and F1 score, at 0.844 and 0.815.

CONCLUSION: Renal multiparametric MRI supports noninvasive early CKD detection. DWI was the most important single sequence. Multi sequence integration improved diagnostic performance, while T1WI+DWI offered a practical balance between performance and feasibility.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu, Gong, Liu, et al. Optimization of Multiparametric MRI Sequence Combinations for Early Detection of Chronic Kidney Disease. Acad Radiol. 2026. PMID: 42502024. doi:10.1016/j.acra.2026.07.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。