指南与共识甲状腺与浅表US

AI辅助评估甲状腺结节中等可疑分类:三种TI-RADS对比

Evaluating the Intermediate Suspicion Category in Thyroid Nodules With Artificial Intelligence Assistance: A Comparative Analysis of C-TIRADS, ACR-TIRADS, and American Thyroid Association Guidelines.
指南 / 共识 · J Am Coll Radiol · 2026-07-24

本研究回顾性分析1040例患者1911张甲状腺结节超声图像,比较ACR-TIRADS、ATA指南及C-TIRADS中等可疑分类在有无AI辅助下的诊断效能与FNA决策。结果显示AI辅助可提升三种系统的诊断准确性,C-TIRADS联合AI表现出最高的准确性、特异度及阳性预测值。

要点

  • 中等可疑结节诊断准确性低于整体队列,阅片时需更审慎。
  • AI辅助可显著提高诊断准确性并降低不必要FNA率。
  • C-TIRADS 4B联合AI在中等级别中准确性最高。

核心结论

  • AI辅助判读可提升中等可疑甲状腺结节的诊断准确性,并改善FNA决策。
  • 三种系统中,C-TIRADS联合AI表现出最优的诊断效能,准确率、特异度、阳性预测值最高。

研究设计与样本

  • 回顾性研究,纳入1040例患者共1911张甲状腺结节超声图像,采集时间为2021至2022年。
  • 中等可疑分类定义为ACR-TIRADS TR4级、ATA第4级及C-TIRADS 4B级。
  • 7名放射科医师独立依据各指南分类结节,另有AI模型独立评估所有结节。
  • 使用患者层面聚类逻辑广义估计方程评估诊断效能及95%置信区间。

诊断标准与关键数值

  • 无AI时FNA率:ACR-TIRADS为37.7%,C-TIRADS为52.2%。
  • 有AI辅助时,ATA第4级FNA率最低为14.7%;C-TIRADS 4B漏诊恶性率最低为29.8%,恶性检出率最高为70.0%。

临床应用与阅片要点

  • 对于报告为中等可疑的甲状腺结节,应意识到其诊断准确性低于总体。
  • 可借助AI辅助判读来提升中等可疑结节的分类信心和FNA决策合理性。
  • C-TIRADS 4B联合AI在中等级别有较好的特异度和阳性预测值,适合需要控制假阳性的读片场景。

局限性

  • 本研究为回顾性设计。
  • 文中未提供多中心信息,研究本身可能为单中心数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare diagnostic performance and fine-needle aspiration (FNA) decision making for thyroid nodules classified as "intermediate suspicion" across three major ultrasound-based risk stratification systems (2017 ACR Thyroid Imaging Reporting and Data System [ACR-TIRADS], 2015 American Thyroid Association (ATA) guidelines, and 2020 Chinese Thyroid Imaging Reporting and Data System [C-TIRADS]), with and without artificial intelligence (AI) assistance.

METHODS: This retrospective study analyzed 1,911 ultrasound images of thyroid nodules from 1,040 patients (mean age, 46.1 ± 13.1 years) collected between 2021 and 2022. The intermediate suspicion category was defined as ACR-TIRADS level TR4 ("moderately suspicious"), ATA level 4, and "moderate suspicion" in C-TIRADS (level 4B). Seven radiologists independently categorized nodules according to each guideline, and an AI model independently evaluated all nodules. AI-assisted diagnostic and FNA strategies were implemented and compared across the three guidelines. Diagnostic performance and 95% confidence intervals were assessed using patient-level clustered logistic generalized estimating equations.

RESULTS: In the intermediate suspicion category, diagnostic accuracy was lower for both radiologists and the AI model than in the overall cohort. Radiologists' overall accuracy increased from 66.4% to 71.4% without AI to 74.1% to 79.4% with AI across all three guidelines (P < .001). With AI, C-TIRADS achieved the highest accuracy (79.4%), specificity (66.7%), and positive predictive value (77.4%) (all P < .05), with no significant differences between ACR-TIRADS and ATA guidelines. Without AI, FNA rates were lowest with ACR-TIRADS (37.7%) and highest with C-TIRADS (52.2%). AI assistance reduced FNA rates by 20.3% to 34.7%, increased malignant detection rate by 15.0% to 23.4%, and decreased missed malignancy rate by 23.7% to 36.8% (all P < .001). With AI assistance, ATA level 4 had the lowest FNA rate (14.7%), whereas moderate suspicion in C-TIRADS (level 4B) had the lowest missed malignancy rate (29.8%) and the numerically highest malignant detection rate (70.0%).

DISCUSSION: AI-assisted interpretation improves diagnostic accuracy and FNA decision making for intermediate suspicion nodules. C-TIRADS combined with AI shows superior performance among the three systems.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Lin, Chen, Huang, et al. Evaluating the Intermediate Suspicion Category in Thyroid Nodules With Artificial Intelligence Assistance: A Comparative Analysis of C-TIRADS, ACR-TIRADS, and American Thyroid Association Guidelines. J Am Coll Radiol. 2026. PMID: 42498197. doi:10.1016/j.jacr.2026.07.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。