文献速递骨肌神经MR

7T 3D DESS 颈神经成像:并行采集联合深度学习重建加速研究

Accelerated 7T 3D DESS MR Neurography of the Cervical Spine Using CS-CAIPIRINHA and Deep Learning Reconstruction.
PubMed 文献 · Invest Radiol · 2026-07-24

评估DL-CAIPIRINHA和DL-CS-CAIPI在不同加速因子下的图像质量及相关影像特征。结果显示2倍和4倍DL-CAIPIRINHA图像质量优于GRAPPA且扫描时间减半,联合CS可在超过6倍加速下保持图像质量。

要点

  • 4倍DL-CAIPIRINHA在颈髓、神经根丝和背根神经节锐利度方面最优,可优先选择。
  • 加速因子≥4时运动伪影显著减少,有助于缩短扫描时间并减少运动影响。
  • 12倍与16倍DL-CS-CAIPI重建伪影少于12倍DL-CAIPIRINHA,高加速时推荐联合CS方案。

核心结论

  • 相干CAIPIRINHA欠采样联合DL重建的图像质量优于常规GRAPPA,同时使7T颈椎MRI扫描时间缩短50%。
  • 在相干欠采样基础上加入非相干压缩感知欠采样,可实现大幅加速并减少重建伪影,加速因子超过8时仍保持图像质量。
  • CAIPIRINHA与CS联合DL重建为高效高分辨率颈椎MRI提供了扫描时间减少超过6倍的稳健框架。

研究设计与样本

  • 采用7T MRI颈椎扫描,参考序列为高分辨率三维DESS序列(重建体素0.35 mm³各向同性),行常规2倍GRAPPA欠采样。
  • 在保持其余成像参数不变的情况下,重复采集单独CAIPIRINHA相干欠采样及CAIPIRINHA联合非相干CS欠采样的DL重建序列。
  • DL-CAIPIRINHA加速因子为R=2至12,DL-CS-CAIPI加速因子为R=4至16。
  • 由两名接受过专科培训的肌骨放射科医师采用5分Likert量表进行图像质量评估。

关键影像表现/征象

  • 所有DL重建方案均显著降低噪声(P<0.001)。
  • 12倍DL-CAIPIRINHA的重建伪影评分(1.6)比12倍和16倍DL-CS-CAIPI(3.1至3.3)更明显(P<0.001)。
  • 加速因子≥4时运动伪影显著减少(P<0.001)。
  • 4倍DL-CAIPIRINHA对脊髓、椎管内神经根丝/神经根及DRG的锐利度评分最高(4.2至4.7),对比GRAPPA为2.9至3.2(P<0.001)。
  • 各项影像特征的两名阅片者间一致性几乎完美(κ=0.85至0.95)。

诊断标准与关键数值

  • 2倍和4倍DL-CAIPIRINHA的图像质量评分均值为4.4至4.6,显著高于GRAPPA的3.2(P<0.001)。
  • 4倍和8倍DL-CS-CAIPI的图像质量评分均值为3.8至3.9,显著高于GRAPPA(P<0.001)。
  • 12倍DL-CS-CAIPI的图像质量与GRAPPA相当(P=0.42),扫描时间减少超过6倍。

临床应用与阅片要点

  • 在7T颈椎MRI中,4倍DL-CAIPIRINHA是图像质量与扫描时间兼优的选择,可优先应用于颈神经根丝与DRG显示。
  • 需要大幅缩短扫描时间或患者耐受性差时,8至12倍DL-CS-CAIPI可在保持图像质量的前提下显著减少扫描时间。
  • 高倍加速时优先选择CAIPIRINHA联合CS的DL重建方案,以减少重建伪影对诊断的干扰。

局限性

  • 研究对象为无症状志愿者,结果推广到有颈神经病变患者需进一步验证。
  • 该研究仅评估图像质量和伪影,未进行诊断准确性的临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the potential of combined coherent and incoherent undersampling with deep learning (DL) reconstruction for highly accelerated high-resolution three-dimensional (3D) double-echo steady-state (DESS) MRI of the cervical nerves and rootlets at 7T.

METHODS: In this prospective study, asymptomatic volunteers underwent 7T MRI of the cervical spine. A high-resolution, 3D DESS sequence (reconstructed voxel size 0.35 mm³ isotropic) with regular 2-fold GRAPPA undersampling served as reference. The sequence was repeated with coherent CAIPIRINHA undersampling alone and combined CAIPIRINHA + incoherent compressed sensing (CS)-based undersampling with DL reconstruction and varying acceleration factors (DL-CAIPIRINHA: R=2 to 12 and DL-CS-CAIPI: R=4 to 16), while all other imaging parameters remained constant. Two fellowship-trained musculoskeletal radiologists assessed image quality, noise, reconstruction and motion artifacts, and edge sharpness of the spinal cord, intradural rootlets/roots, and exiting spinal nerves, including dorsal root ganglia (DRGs), using 5-point Likert scales, with higher scores indicating better image quality or fewer artifacts. Statistics included Friedman and post hoc Wilcoxon signed-rank tests (Benjamini-Hochberg corrected) and κ statistics.

RESULTS: Thirty-two volunteers (mean age 30.9±7.2 y; mean BMI 23.4±2.8 kg/m²; 16 females) were included. Image quality significantly improved with 2- and 4-fold DL-CAIPIRINHA (means 4.4 to 4.6) and 4- and 8-fold DL-CS-CAIPI (3.8 to 3.9) compared with GRAPPA (3.2; all P<0.001), and remained comparable with 12-fold DL-CS-CAIPI (P=0.42) despite more than 6-fold reduction in scan time. All DL-based reconstructions reduced noise (P<0.001). Reconstruction artifacts were more pronounced for 12-fold DL-CAIPIRINHA (1.6) than for 12- and 16-fold DL-CS-CAIPI (3.1 to 3.3; P<0.001). Motion artifacts decreased with acceleration factors ≥4 (P<0.001). Sharpness of the spinal cord, intraspinal rootlets/roots, and DRGs was highest with 4-fold DL-CAIPIRINHA (4.2 to 4.7) vs. GRAPPA (2.9 to 3.2; P<0.001). Inter-reader agreement was almost perfect across all imaging features (κ=0.85 to 0.95).

CONCLUSIONS: Coherent CAIPIRINHA undersampling with DL reconstruction improves image quality over conventional GRAPPA while enabling 50% faster imaging in 7T cervical spine MRI. Adding incoherent CS undersampling permits substantially higher acceleration with preserved image quality and fewer reconstruction artifacts. The novel integration of coherent and incoherent undersampling via combined CAIPIRINHA and CS with DL reconstruction provides a robust framework for preserving image quality at acceleration factors beyond 8, enabling efficient high-resolution cervical spine MRI with scan time reductions exceeding 6-fold.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Abel, von Deuster, Walch, et al. Accelerated 7T 3D DESS MR Neurography of the Cervical Spine Using CS-CAIPIRINHA and Deep Learning Reconstruction. Invest Radiol. 2026. PMID: 42494204. doi:10.1097/RLI.0000000000001305

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。