文献速递胸部介入CT

CT引导肺活检后盐水针道封闭预防气胸的系统综述与Meta分析

Saline tract sealing to prevent pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy: a systematic review and meta-analysis.
PubMed 文献 · Clin Radiol · 2026-07-01

本系统综述与Meta分析纳入7项研究共1455例接受CT引导经皮肺活检的成人,其中680例接受即刻生理盐水针道封闭。结果显示盐水针道封闭可显著降低活检后气胸风险及胸管置入需求,可作为操作中的辅助技术。

要点

  • CT引导肺活检后气胸发生率约25%,其中5-6%需胸管置入。
  • 盐水针道封闭降低气胸风险(RR 0.46)及胸管需求(RR 0.22)。
  • 盐水便宜、易得,可作为操作中可考虑的辅助技术。

核心结论

  • CT引导肺活检后即刻向针道注入无菌生理盐水可显著降低气胸发生率和胸管置入需求。
  • 盐水针道封闭可作为CT引导肺活检过程中的辅助技术予以考虑。

研究设计与样本

  • 该系统综述与Meta分析遵循PRISMA指南,纳入随机对照试验和比较性队列研究。
  • 研究对象为接受CT引导经皮肺活检的成人,干预为向活检针道即刻注入无菌生理盐水,对照为不进行针道封闭。
  • 共纳入7项研究,合计1455例患者,其中680例接受了生理盐水针道封闭。

诊断标准与关键数值

  • 盐水针道封闭显著降低气胸风险:风险比(RR)为0.46,95%置信区间0.35-0.61,P<0.00001。
  • 盐水针道封闭显著降低胸管置入需求:风险比(RR)为0.22,95%置信区间0.12-0.42,P<0.0001。

临床应用与阅片要点

  • CT引导肺活检后气胸是最常见并发症,报告随访胸片时应重点观察有无新发气胸。
  • 盐水针道封闭是一种可在操作过程中采用的廉价且易获得的辅助技术。
  • 相比之下,自体血、纤维蛋白胶和胶原塞虽可降低风险但较昂贵或可能引起局部反应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Pneumothorax is the most common complication of computed tomography (CT)-guided lung biopsy, occurring in approximately 25% of cases, with 5-6% requiring chest tube placement. Tract-sealing techniques such as autologous blood, fibrin glue, and collagen plugs can reduce this risk but are costly or may cause local reactions. Saline tract sealing is an inexpensive and widely available alternative, but evidence of its effectiveness is limited.

MATERIALS AND METHODS: We performed a systematic review and meta-analysis of randomised controlled trials and comparative cohort studies including adults undergoing CT-guided percutaneous lung biopsy, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The intervention was immediate instillation of sterile saline into the biopsy tract, compared with no sealing. The outcomes analysed were postbiopsy pneumothorax and chest tube placement.

RESULTS: Seven studies (1455 patients; 680 received saline) were included. Saline tract sealing significantly reduced the risk of pneumothorax (risk ratios [RR]: 0.46; 95% confidence interval [CI]: 0.35-0.61; P < 0.00001) and the need for chest tube placement (RR: 0.22; 95% CI: 0.12-0.42; P < 0.0001).

CONCLUSION: Saline tract sealing is associated with a significant reduction in pneumothorax and the need for chest tube placement after CT-guided lung biopsy and may be considered an adjunctive technique during the procedure.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Pille, Pinheiro, Alano, et al. Saline tract sealing to prevent pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy: a systematic review and meta-analysis. Clin Radiol. 2026. PMID: 42480290. doi:10.1016/j.crad.2026.107423

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。