文献速递头颈MR

GRASP DCE-MRI 监测头颈部副神经节瘤 SRS 疗效

GRASP Dynamic Contrast-Enhanced MRI Can Be Used to Monitor Response to Stereotactic Radiosurgery in Head and Neck Paragangliomas.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-07-21

本研究回顾性分析 14 例接受伽玛刀 SRS 治疗的头颈部副神经节瘤患者,在治疗前后行 GRASP DCE-MRI 检查。结果显示 SRS 后肿瘤体积变化有限,但归一化流入斜率、流出斜率和峰值强化均显著降低。提示 GRASP DCE-MRI 可反映 SRS 后血管通透性改变,有望作为疗效评价的功能影像标志物。

要点

  • SRS 后肿瘤体积常无明显缩小,常规增强评估疗效存在局限。
  • GRASP DCE-MRI 的流入、流出斜率及峰值强化可反映血管通透性变化。
  • 功能成像应整合到 HNPGL 术后常规 MRI 随访中。

核心结论

  • GRASP DCE-MRI 可检测 HNPGL 经 SRS 后强化动力学的显著变化,提示其可作为治疗反应的生物标志物。
  • 研究支持将功能成像与常规 MRI 序列整合用于头颈部副神经节瘤治疗后评估。

研究设计与样本

  • 回顾性研究,纳入 2015—2024 年于单中心接受伽玛刀 SRS 且有治疗前后 GRASP DCE-MRI 的 14 例头颈部副神经节瘤患者。
  • 采用配对统计检验比较 SRS 前后各强化动力学参数及肿瘤体积。

关键影像表现/征象

  • SRS 后肿瘤体积仅轻度缩小或稳定,中位体积变化为−0.18 mL(P=.001)。
  • SRS 后归一化流入斜率显著降低(P=.01)。
  • SRS 后归一化流出斜率显著降低(P=.01)。
  • SRS 后归一化峰值强化显著降低(P=.02)。

诊断标准与关键数值

  • 治疗前后成像中位间隔为 26 个月。
  • 强化动力学参数包括流入斜率、流出斜率、峰值强化和达峰时间,均以上矢状窦为参照进行归一化。
  • 肿瘤体积在增强后图像上测量计算。

临床应用与阅片要点

  • 在 HNPGL 接受 SRS 后随访中,体积或常规增强表现变化不明显时,可借助 GRASP DCE-MRI 观察强化动力学变化。
  • 流入斜率、流出斜率和峰值强化的下降可能提示 SRS 后肿瘤血管通透性降低,反映治疗控制效果。
  • 将功能序列纳入 HNPGL 术后 MRI 随访方案可能提高疗效判断的敏感性。

局限性

  • 本研究为回顾性分析,样本量仅 14 例。
  • 原文所述回顾性、单中心设计本身存在固有局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Stereotactic radiosurgery (SRS) is an effective management approach for many patients with head and neck paragangliomas (HNPGLs). However, treated paragangliomas may not significantly decrease in volume or subjective enhancement on conventional MRI. We investigated the utility of dynamic contrast-enhanced MRI (DCE-MRI) using golden-angle radial sparse parallel (GRASP) technique to detect vascular changes in HNPGLs after SRS, hypothesizing that controlled paragangliomas would demonstrate evidence of lower permeability post-SRS.

MATERIALS AND METHODS: We retrospectively analyzed 14 patients with HNPGLs managed with gamma-knife SRS from 2015 to 2024 at our institution who had GRASP DCE-MRI before and after treatment. Tumor enhancement kinetics were quantified using wash-in slope, wash-out slope, peak enhancement, and time to peak, normalized to the superior sagittal sinus. Tumors volumes were calculated from postcontrast images. Pre- and post-SRS parameters were compared using paired statistical tests.

RESULTS: Median time between pre- and post-SRS imaging was 26 months. Tumor volume decreased modestly (median change -0.18 mL, p=.001) or remained stable in all but one case. Significant reductions were observed in normalized wash-in slope (p=.01), wash-out slope (p=.01), and peak enhancement (p=.02) following SRS.

CONCLUSIONS: GRASP DCE-MRI detected significant changes in enhancement kinetics of HNPGLs following SRS, suggesting that dynamic imaging may serve as a biomarker of treatment response. These findings support the integration of functional imaging alongside conventional MRI sequences in post-treatment assessment of HNPGL.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Khan, Lee, Ismail, et al. GRASP Dynamic Contrast-Enhanced MRI Can Be Used to Monitor Response to Stereotactic Radiosurgery in Head and Neck Paragangliomas. AJNR Am J Neuroradiol. 2026. PMID: 42481417. doi:10.3174/ajnr.A9539

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。